A bioluminescent sensor for high throughput toxicity classification

Byoung Chan Kim, Man Bock Gu

Research output: Contribution to journalArticle

47 Citations (Scopus)

Abstract

A high throughput toxicity monitoring and classification biosensor system has been successfully developed using four immobilized bioluminescent Escherichia coli strains, DPD2511, DPD2540, DPD2794 and TV1061, which have plasmids bearing a fusion of a specific promoter to the luxCDABE operon. The bioluminescence of DPD2511 increases in the presence of oxidative damage, DPD2540 by membrane damage, DPD2794 by DNA damage and TV1061 by protein damage. In the developed biosensor these strains are immobilized in a single 96 well plate using an LB-agar matrix, and are able to detect the toxicities of hydrogen peroxide, phenol and mitomycin C in water samples. As the concentration of each chemical was increased, the bioluminescence levels from the corresponding wells, containing either DPD2511, DPD2540, DPD2794 or TV1061, increased. This increase in bioluminescence followed a dose dependent response to the toxic chemicals within a specific concentration range. In particular, each test requires only 4 h to give clear bioluminescent response signature. Storage of the biosensor at 4°C for 2 weeks caused no change in its dose-dependent response. The fast and easy detection of oxidative, membrane, protein and DNA damaging agents in aqueous environments is possible due to the high throughput capability of this biosensor.

Original languageEnglish
Pages (from-to)1015-1021
Number of pages7
JournalBiosensors and Bioelectronics
Volume18
Issue number8
DOIs
Publication statusPublished - 2003 Aug 1
Externally publishedYes

Fingerprint

Biosensing Techniques
Bioluminescence
Biosensors
Toxicity
Throughput
Sensors
DNA
Bearings (structural)
Proteins
Membranes
Poisons
Mitomycin
Operon
Phenol
Hydrogen peroxide
Escherichia coli
Hydrogen Peroxide
DNA Damage
Phenols
Agar

Keywords

  • 96 Well plate
  • High throughput
  • Immobilization
  • Recombinant bioluminescent bacteria
  • Toxicity monitoring and classification

ASJC Scopus subject areas

  • Biotechnology
  • Analytical Chemistry
  • Electrochemistry

Cite this

A bioluminescent sensor for high throughput toxicity classification. / Kim, Byoung Chan; Gu, Man Bock.

In: Biosensors and Bioelectronics, Vol. 18, No. 8, 01.08.2003, p. 1015-1021.

Research output: Contribution to journalArticle

@article{23e3a83251b343c5a7a0cf69dccd37c5,
title = "A bioluminescent sensor for high throughput toxicity classification",
abstract = "A high throughput toxicity monitoring and classification biosensor system has been successfully developed using four immobilized bioluminescent Escherichia coli strains, DPD2511, DPD2540, DPD2794 and TV1061, which have plasmids bearing a fusion of a specific promoter to the luxCDABE operon. The bioluminescence of DPD2511 increases in the presence of oxidative damage, DPD2540 by membrane damage, DPD2794 by DNA damage and TV1061 by protein damage. In the developed biosensor these strains are immobilized in a single 96 well plate using an LB-agar matrix, and are able to detect the toxicities of hydrogen peroxide, phenol and mitomycin C in water samples. As the concentration of each chemical was increased, the bioluminescence levels from the corresponding wells, containing either DPD2511, DPD2540, DPD2794 or TV1061, increased. This increase in bioluminescence followed a dose dependent response to the toxic chemicals within a specific concentration range. In particular, each test requires only 4 h to give clear bioluminescent response signature. Storage of the biosensor at 4°C for 2 weeks caused no change in its dose-dependent response. The fast and easy detection of oxidative, membrane, protein and DNA damaging agents in aqueous environments is possible due to the high throughput capability of this biosensor.",
keywords = "96 Well plate, High throughput, Immobilization, Recombinant bioluminescent bacteria, Toxicity monitoring and classification",
author = "Kim, {Byoung Chan} and Gu, {Man Bock}",
year = "2003",
month = "8",
day = "1",
doi = "10.1016/S0956-5663(02)00220-8",
language = "English",
volume = "18",
pages = "1015--1021",
journal = "Biosensors",
issn = "0956-5663",
publisher = "Elsevier Limited",
number = "8",

}

TY - JOUR

T1 - A bioluminescent sensor for high throughput toxicity classification

AU - Kim, Byoung Chan

AU - Gu, Man Bock

PY - 2003/8/1

Y1 - 2003/8/1

N2 - A high throughput toxicity monitoring and classification biosensor system has been successfully developed using four immobilized bioluminescent Escherichia coli strains, DPD2511, DPD2540, DPD2794 and TV1061, which have plasmids bearing a fusion of a specific promoter to the luxCDABE operon. The bioluminescence of DPD2511 increases in the presence of oxidative damage, DPD2540 by membrane damage, DPD2794 by DNA damage and TV1061 by protein damage. In the developed biosensor these strains are immobilized in a single 96 well plate using an LB-agar matrix, and are able to detect the toxicities of hydrogen peroxide, phenol and mitomycin C in water samples. As the concentration of each chemical was increased, the bioluminescence levels from the corresponding wells, containing either DPD2511, DPD2540, DPD2794 or TV1061, increased. This increase in bioluminescence followed a dose dependent response to the toxic chemicals within a specific concentration range. In particular, each test requires only 4 h to give clear bioluminescent response signature. Storage of the biosensor at 4°C for 2 weeks caused no change in its dose-dependent response. The fast and easy detection of oxidative, membrane, protein and DNA damaging agents in aqueous environments is possible due to the high throughput capability of this biosensor.

AB - A high throughput toxicity monitoring and classification biosensor system has been successfully developed using four immobilized bioluminescent Escherichia coli strains, DPD2511, DPD2540, DPD2794 and TV1061, which have plasmids bearing a fusion of a specific promoter to the luxCDABE operon. The bioluminescence of DPD2511 increases in the presence of oxidative damage, DPD2540 by membrane damage, DPD2794 by DNA damage and TV1061 by protein damage. In the developed biosensor these strains are immobilized in a single 96 well plate using an LB-agar matrix, and are able to detect the toxicities of hydrogen peroxide, phenol and mitomycin C in water samples. As the concentration of each chemical was increased, the bioluminescence levels from the corresponding wells, containing either DPD2511, DPD2540, DPD2794 or TV1061, increased. This increase in bioluminescence followed a dose dependent response to the toxic chemicals within a specific concentration range. In particular, each test requires only 4 h to give clear bioluminescent response signature. Storage of the biosensor at 4°C for 2 weeks caused no change in its dose-dependent response. The fast and easy detection of oxidative, membrane, protein and DNA damaging agents in aqueous environments is possible due to the high throughput capability of this biosensor.

KW - 96 Well plate

KW - High throughput

KW - Immobilization

KW - Recombinant bioluminescent bacteria

KW - Toxicity monitoring and classification

UR - http://www.scopus.com/inward/record.url?scp=0038695870&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0038695870&partnerID=8YFLogxK

U2 - 10.1016/S0956-5663(02)00220-8

DO - 10.1016/S0956-5663(02)00220-8

M3 - Article

VL - 18

SP - 1015

EP - 1021

JO - Biosensors

JF - Biosensors

SN - 0956-5663

IS - 8