A complete metal jacket case using ten paclitaxel-eluting stents for multiple de novo coronary artery lesions

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Although full metal jacket using drug-eluting stent (DES) for a single coronary artery disease has sparsely been described before, there is no report of safety and efficacy of complete metal jacket from left main (LM) to three major coronary arteries. We report a complete metal jacket case using 10 paclitaxel-eluting stents (PES; Taxus™, Boston Scientific) for a triple vessel diffuse de novo coronary diseases who refused coronary artery bypass graft.

Original languageEnglish
JournalInternational Journal of Cardiology
Volume115
Issue number2
DOIs
Publication statusPublished - 2007 Feb 7

Fingerprint

Paclitaxel
Stents
Coronary Vessels
Metals
Taxus
Drug-Eluting Stents
Coronary Artery Bypass
Coronary Disease
Coronary Artery Disease
Transplants
Safety

Keywords

  • Drug-eluting stent
  • Metal jacket
  • Multivessel disease

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

@article{afa65066ca0e4844b590212c173413e9,
title = "A complete metal jacket case using ten paclitaxel-eluting stents for multiple de novo coronary artery lesions",
abstract = "Although full metal jacket using drug-eluting stent (DES) for a single coronary artery disease has sparsely been described before, there is no report of safety and efficacy of complete metal jacket from left main (LM) to three major coronary arteries. We report a complete metal jacket case using 10 paclitaxel-eluting stents (PES; Taxus™, Boston Scientific) for a triple vessel diffuse de novo coronary diseases who refused coronary artery bypass graft.",
keywords = "Drug-eluting stent, Metal jacket, Multivessel disease",
author = "Suh, {Soon Yong} and Seung-Woon Rha and Choi, {Cheol Ung} and Kim, {Jin Won} and Kim, {Eung Ju} and Park, {Chang Gyu} and Seo, {Hong Seog} and Oh, {Dong Joo}",
year = "2007",
month = "2",
day = "7",
doi = "10.1016/j.ijcard.2006.08.098",
language = "English",
volume = "115",
journal = "International Journal of Cardiology",
issn = "0167-5273",
publisher = "Elsevier Ireland Ltd",
number = "2",

}

TY - JOUR

T1 - A complete metal jacket case using ten paclitaxel-eluting stents for multiple de novo coronary artery lesions

AU - Suh, Soon Yong

AU - Rha, Seung-Woon

AU - Choi, Cheol Ung

AU - Kim, Jin Won

AU - Kim, Eung Ju

AU - Park, Chang Gyu

AU - Seo, Hong Seog

AU - Oh, Dong Joo

PY - 2007/2/7

Y1 - 2007/2/7

N2 - Although full metal jacket using drug-eluting stent (DES) for a single coronary artery disease has sparsely been described before, there is no report of safety and efficacy of complete metal jacket from left main (LM) to three major coronary arteries. We report a complete metal jacket case using 10 paclitaxel-eluting stents (PES; Taxus™, Boston Scientific) for a triple vessel diffuse de novo coronary diseases who refused coronary artery bypass graft.

AB - Although full metal jacket using drug-eluting stent (DES) for a single coronary artery disease has sparsely been described before, there is no report of safety and efficacy of complete metal jacket from left main (LM) to three major coronary arteries. We report a complete metal jacket case using 10 paclitaxel-eluting stents (PES; Taxus™, Boston Scientific) for a triple vessel diffuse de novo coronary diseases who refused coronary artery bypass graft.

KW - Drug-eluting stent

KW - Metal jacket

KW - Multivessel disease

UR - http://www.scopus.com/inward/record.url?scp=33846348568&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33846348568&partnerID=8YFLogxK

U2 - 10.1016/j.ijcard.2006.08.098

DO - 10.1016/j.ijcard.2006.08.098

M3 - Article

C2 - 17126931

AN - SCOPUS:33846348568

VL - 115

JO - International Journal of Cardiology

JF - International Journal of Cardiology

SN - 0167-5273

IS - 2

ER -