A disposable BOD microsensor using a polymer substrate

Mehta Anjum, Halakatti Shekhar, Seung H. Hyun, Seungkwan Hong, Hyoung J. Cho

Research output: Chapter in Book/Report/Conference proceedingConference contribution

5 Citations (Scopus)

Abstract

A disposable microbial sensor was designed, fabricated and tested for standard BOD (Biochemical Oxygen Demand) measurements. A transparent Cyclic Olefin Copolymer (COC) substrate was used for sensor fabrication. Standard lithographic procedures in addition to techniques like screen printing and electroplating were used to fabricate the sensor. A layer of a microbial strain of Trichosporon Cutaneum was immobilized over one pair of sensor electrodes while the other was used as a reference. Depending on the respiratory activities of the microbial strain in different samples, the BOD values of the samples could be measured in terms of difference between the output signals. The sensor layer was enclosed by an injection-molded passive microfluidic channel on the top. The BOD sensor was calibrated and tested with standard BOD solutions and samples obtained from a wastewater reclamation facility. Good correlation with chemically determined BOD5 values was obtained with fast response time. Advantages of the BOD microsensor include (a) fast BOD measurement (b) disposability from a low cost, chemically inert polymer substrate (c) flow-through sample injection scheme and (d) possible future integration of on-chip optics.

Original languageEnglish
Title of host publicationProceedings of IEEE Sensors
EditorsD. Rocha, P.M. Sarro, M.J. Vellekoop
Pages1202-1205
Number of pages4
Volume3
Publication statusPublished - 2004 Dec 1
EventIEEE Sensors 2004 - Vienna, Austria
Duration: 2004 Oct 242004 Oct 27

Other

OtherIEEE Sensors 2004
CountryAustria
CityVienna
Period04/10/2404/10/27

Fingerprint

Microsensors
Biochemical oxygen demand
Sensors
Polymers
Substrates
Disposability
Wastewater reclamation
Screen printing
Electroplating
Microfluidics
Olefins
Optics
Copolymers
Fabrication
Electrodes
Costs

Keywords

  • BOD sensor
  • Disposable sensor
  • Environmental application
  • Flow-through measurement
  • Microbial sensor

ASJC Scopus subject areas

  • Engineering (miscellaneous)
  • Electrical and Electronic Engineering

Cite this

Anjum, M., Shekhar, H., Hyun, S. H., Hong, S., & Cho, H. J. (2004). A disposable BOD microsensor using a polymer substrate. In D. Rocha, P. M. Sarro, & M. J. Vellekoop (Eds.), Proceedings of IEEE Sensors (Vol. 3, pp. 1202-1205). [W1L-C.5]

A disposable BOD microsensor using a polymer substrate. / Anjum, Mehta; Shekhar, Halakatti; Hyun, Seung H.; Hong, Seungkwan; Cho, Hyoung J.

Proceedings of IEEE Sensors. ed. / D. Rocha; P.M. Sarro; M.J. Vellekoop. Vol. 3 2004. p. 1202-1205 W1L-C.5.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Anjum, M, Shekhar, H, Hyun, SH, Hong, S & Cho, HJ 2004, A disposable BOD microsensor using a polymer substrate. in D Rocha, PM Sarro & MJ Vellekoop (eds), Proceedings of IEEE Sensors. vol. 3, W1L-C.5, pp. 1202-1205, IEEE Sensors 2004, Vienna, Austria, 04/10/24.
Anjum M, Shekhar H, Hyun SH, Hong S, Cho HJ. A disposable BOD microsensor using a polymer substrate. In Rocha D, Sarro PM, Vellekoop MJ, editors, Proceedings of IEEE Sensors. Vol. 3. 2004. p. 1202-1205. W1L-C.5
Anjum, Mehta ; Shekhar, Halakatti ; Hyun, Seung H. ; Hong, Seungkwan ; Cho, Hyoung J. / A disposable BOD microsensor using a polymer substrate. Proceedings of IEEE Sensors. editor / D. Rocha ; P.M. Sarro ; M.J. Vellekoop. Vol. 3 2004. pp. 1202-1205
@inproceedings{f241513d69f9453ca372de4ee52aa240,
title = "A disposable BOD microsensor using a polymer substrate",
abstract = "A disposable microbial sensor was designed, fabricated and tested for standard BOD (Biochemical Oxygen Demand) measurements. A transparent Cyclic Olefin Copolymer (COC) substrate was used for sensor fabrication. Standard lithographic procedures in addition to techniques like screen printing and electroplating were used to fabricate the sensor. A layer of a microbial strain of Trichosporon Cutaneum was immobilized over one pair of sensor electrodes while the other was used as a reference. Depending on the respiratory activities of the microbial strain in different samples, the BOD values of the samples could be measured in terms of difference between the output signals. The sensor layer was enclosed by an injection-molded passive microfluidic channel on the top. The BOD sensor was calibrated and tested with standard BOD solutions and samples obtained from a wastewater reclamation facility. Good correlation with chemically determined BOD5 values was obtained with fast response time. Advantages of the BOD microsensor include (a) fast BOD measurement (b) disposability from a low cost, chemically inert polymer substrate (c) flow-through sample injection scheme and (d) possible future integration of on-chip optics.",
keywords = "BOD sensor, Disposable sensor, Environmental application, Flow-through measurement, Microbial sensor",
author = "Mehta Anjum and Halakatti Shekhar and Hyun, {Seung H.} and Seungkwan Hong and Cho, {Hyoung J.}",
year = "2004",
month = "12",
day = "1",
language = "English",
volume = "3",
pages = "1202--1205",
editor = "D. Rocha and P.M. Sarro and M.J. Vellekoop",
booktitle = "Proceedings of IEEE Sensors",

}

TY - GEN

T1 - A disposable BOD microsensor using a polymer substrate

AU - Anjum, Mehta

AU - Shekhar, Halakatti

AU - Hyun, Seung H.

AU - Hong, Seungkwan

AU - Cho, Hyoung J.

PY - 2004/12/1

Y1 - 2004/12/1

N2 - A disposable microbial sensor was designed, fabricated and tested for standard BOD (Biochemical Oxygen Demand) measurements. A transparent Cyclic Olefin Copolymer (COC) substrate was used for sensor fabrication. Standard lithographic procedures in addition to techniques like screen printing and electroplating were used to fabricate the sensor. A layer of a microbial strain of Trichosporon Cutaneum was immobilized over one pair of sensor electrodes while the other was used as a reference. Depending on the respiratory activities of the microbial strain in different samples, the BOD values of the samples could be measured in terms of difference between the output signals. The sensor layer was enclosed by an injection-molded passive microfluidic channel on the top. The BOD sensor was calibrated and tested with standard BOD solutions and samples obtained from a wastewater reclamation facility. Good correlation with chemically determined BOD5 values was obtained with fast response time. Advantages of the BOD microsensor include (a) fast BOD measurement (b) disposability from a low cost, chemically inert polymer substrate (c) flow-through sample injection scheme and (d) possible future integration of on-chip optics.

AB - A disposable microbial sensor was designed, fabricated and tested for standard BOD (Biochemical Oxygen Demand) measurements. A transparent Cyclic Olefin Copolymer (COC) substrate was used for sensor fabrication. Standard lithographic procedures in addition to techniques like screen printing and electroplating were used to fabricate the sensor. A layer of a microbial strain of Trichosporon Cutaneum was immobilized over one pair of sensor electrodes while the other was used as a reference. Depending on the respiratory activities of the microbial strain in different samples, the BOD values of the samples could be measured in terms of difference between the output signals. The sensor layer was enclosed by an injection-molded passive microfluidic channel on the top. The BOD sensor was calibrated and tested with standard BOD solutions and samples obtained from a wastewater reclamation facility. Good correlation with chemically determined BOD5 values was obtained with fast response time. Advantages of the BOD microsensor include (a) fast BOD measurement (b) disposability from a low cost, chemically inert polymer substrate (c) flow-through sample injection scheme and (d) possible future integration of on-chip optics.

KW - BOD sensor

KW - Disposable sensor

KW - Environmental application

KW - Flow-through measurement

KW - Microbial sensor

UR - http://www.scopus.com/inward/record.url?scp=27944453598&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=27944453598&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:27944453598

VL - 3

SP - 1202

EP - 1205

BT - Proceedings of IEEE Sensors

A2 - Rocha, D.

A2 - Sarro, P.M.

A2 - Vellekoop, M.J.

ER -