A generalized correlation for two-phase flow of alternative refrigerants through short tube orifices

Research output: Contribution to journalArticle

27 Citations (Scopus)

Abstract

The objective of this study is to develop a generalized correlation for the prediction of refrigerant flow rate through short tube orifices using alternative refrigerants. The generalized correlations for two-phase and subcooled inlet conditions are separately derived from a power law form of dimensionless parameters generated by the Buckingham Pi theorem. The database for the present correlation includes extensive experimental data for R12, R22, R134a, R407C, R410A, and R502 obtained from the open literature. For subcooled inlet conditions at the short tube entrance, the correlation yields an average deviation of 0.3% and a standard deviation of 6.1% based on the present database, while for two-phase inlet conditons it predicts the database with an average deviation of 0.2% and a standard deviation of 5.0%. The relative deviations of the predictions using the present correlations for two-phase and subcooled inlet conditions range from -21% to 18%.

Original languageEnglish
Pages (from-to)393-400
Number of pages8
JournalInternational Journal of Refrigeration
Volume27
Issue number4
DOIs
Publication statusPublished - 2004 Jun 1

Fingerprint

Refrigerants
Orifices
Two phase flow
Databases
Flow of fluids
Flow rate
prediction

Keywords

  • Correlation
  • Orifices
  • Refrigerant
  • Tubes
  • Two-phase flow

ASJC Scopus subject areas

  • Food Science
  • Mechanical Engineering

Cite this

A generalized correlation for two-phase flow of alternative refrigerants through short tube orifices. / Choi, Jongmin; Chung, Jin Taek; Kim, Yong Chan.

In: International Journal of Refrigeration, Vol. 27, No. 4, 01.06.2004, p. 393-400.

Research output: Contribution to journalArticle

@article{29853e466b0b4ce0a6057fde93e0d526,
title = "A generalized correlation for two-phase flow of alternative refrigerants through short tube orifices",
abstract = "The objective of this study is to develop a generalized correlation for the prediction of refrigerant flow rate through short tube orifices using alternative refrigerants. The generalized correlations for two-phase and subcooled inlet conditions are separately derived from a power law form of dimensionless parameters generated by the Buckingham Pi theorem. The database for the present correlation includes extensive experimental data for R12, R22, R134a, R407C, R410A, and R502 obtained from the open literature. For subcooled inlet conditions at the short tube entrance, the correlation yields an average deviation of 0.3{\%} and a standard deviation of 6.1{\%} based on the present database, while for two-phase inlet conditons it predicts the database with an average deviation of 0.2{\%} and a standard deviation of 5.0{\%}. The relative deviations of the predictions using the present correlations for two-phase and subcooled inlet conditions range from -21{\%} to 18{\%}.",
keywords = "Correlation, Orifices, Refrigerant, Tubes, Two-phase flow",
author = "Jongmin Choi and Chung, {Jin Taek} and Kim, {Yong Chan}",
year = "2004",
month = "6",
day = "1",
doi = "10.1016/j.ijrefrig.2003.11.008",
language = "English",
volume = "27",
pages = "393--400",
journal = "International Journal of Refrigeration",
issn = "0140-7007",
publisher = "Elsevier Limited",
number = "4",

}

TY - JOUR

T1 - A generalized correlation for two-phase flow of alternative refrigerants through short tube orifices

AU - Choi, Jongmin

AU - Chung, Jin Taek

AU - Kim, Yong Chan

PY - 2004/6/1

Y1 - 2004/6/1

N2 - The objective of this study is to develop a generalized correlation for the prediction of refrigerant flow rate through short tube orifices using alternative refrigerants. The generalized correlations for two-phase and subcooled inlet conditions are separately derived from a power law form of dimensionless parameters generated by the Buckingham Pi theorem. The database for the present correlation includes extensive experimental data for R12, R22, R134a, R407C, R410A, and R502 obtained from the open literature. For subcooled inlet conditions at the short tube entrance, the correlation yields an average deviation of 0.3% and a standard deviation of 6.1% based on the present database, while for two-phase inlet conditons it predicts the database with an average deviation of 0.2% and a standard deviation of 5.0%. The relative deviations of the predictions using the present correlations for two-phase and subcooled inlet conditions range from -21% to 18%.

AB - The objective of this study is to develop a generalized correlation for the prediction of refrigerant flow rate through short tube orifices using alternative refrigerants. The generalized correlations for two-phase and subcooled inlet conditions are separately derived from a power law form of dimensionless parameters generated by the Buckingham Pi theorem. The database for the present correlation includes extensive experimental data for R12, R22, R134a, R407C, R410A, and R502 obtained from the open literature. For subcooled inlet conditions at the short tube entrance, the correlation yields an average deviation of 0.3% and a standard deviation of 6.1% based on the present database, while for two-phase inlet conditons it predicts the database with an average deviation of 0.2% and a standard deviation of 5.0%. The relative deviations of the predictions using the present correlations for two-phase and subcooled inlet conditions range from -21% to 18%.

KW - Correlation

KW - Orifices

KW - Refrigerant

KW - Tubes

KW - Two-phase flow

UR - http://www.scopus.com/inward/record.url?scp=1642634477&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=1642634477&partnerID=8YFLogxK

U2 - 10.1016/j.ijrefrig.2003.11.008

DO - 10.1016/j.ijrefrig.2003.11.008

M3 - Article

AN - SCOPUS:1642634477

VL - 27

SP - 393

EP - 400

JO - International Journal of Refrigeration

JF - International Journal of Refrigeration

SN - 0140-7007

IS - 4

ER -