A kinematic arm model based on the transverse elbow axis

Eui Seung Jung, Bumyoung Woo, Myung Yun

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

To determine the exact direction and location of the human joint in motion is crucial in developing an accurate human model. All the previous studies investigated, in vitro, the passive movement of the joint from cadavers and the suggested location of the joint axis was difficult to make practical applications due to the lack of the direction of joint axis. So, each joint axis has been assumed to lie horizontally or vertically to the adjacent links in many biomechanical models. In this study, the direction and location of the transverse elbow axis was obtained with respect to the global coordinate system whose origin is on the lateral epicondyle of the humerus. From the experiments conducted for five subjects, the direction and location of the transverse elbow axis was determined for each subject by the helical axis method. A statistical validation was also performed to confirm the result. The result was applied to develop an elbow model, which is apart of the kinematic arm model. The elbow model was developed to validate the significance of the result and the kinematic arm model was able to describe the geometry of any complex linkage system. As a result, the errors incurred from the proposed model were significantly reduced when compared to the ones from existing models.

Original languageEnglish
Title of host publicationProceedings of the XIVth Triennial Congress of the International Ergonomics Association and 44th Annual Meeting of the Human Factors and Ergonomics Association, 'Ergonomics for the New Millennium'
Pages592-595
Number of pages4
Publication statusPublished - 2000 Dec 1
EventProceedings of the XIVth Triennial Congress of the International Ergonomics Association and 44th Annual Meeting of the Human Factors and Ergonomics Association, 'Ergonomics for the New Millennnium' - San Diego, CA, United States
Duration: 2000 Jul 292000 Aug 4

Other

OtherProceedings of the XIVth Triennial Congress of the International Ergonomics Association and 44th Annual Meeting of the Human Factors and Ergonomics Association, 'Ergonomics for the New Millennnium'
CountryUnited States
CitySan Diego, CA
Period00/7/2900/8/4

Fingerprint

Kinematics
mathematics
Geometry
lack
experiment
Experiments

ASJC Scopus subject areas

  • Human Factors and Ergonomics

Cite this

Jung, E. S., Woo, B., & Yun, M. (2000). A kinematic arm model based on the transverse elbow axis. In Proceedings of the XIVth Triennial Congress of the International Ergonomics Association and 44th Annual Meeting of the Human Factors and Ergonomics Association, 'Ergonomics for the New Millennium' (pp. 592-595)

A kinematic arm model based on the transverse elbow axis. / Jung, Eui Seung; Woo, Bumyoung; Yun, Myung.

Proceedings of the XIVth Triennial Congress of the International Ergonomics Association and 44th Annual Meeting of the Human Factors and Ergonomics Association, 'Ergonomics for the New Millennium'. 2000. p. 592-595.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Jung, ES, Woo, B & Yun, M 2000, A kinematic arm model based on the transverse elbow axis. in Proceedings of the XIVth Triennial Congress of the International Ergonomics Association and 44th Annual Meeting of the Human Factors and Ergonomics Association, 'Ergonomics for the New Millennium'. pp. 592-595, Proceedings of the XIVth Triennial Congress of the International Ergonomics Association and 44th Annual Meeting of the Human Factors and Ergonomics Association, 'Ergonomics for the New Millennnium', San Diego, CA, United States, 00/7/29.
Jung ES, Woo B, Yun M. A kinematic arm model based on the transverse elbow axis. In Proceedings of the XIVth Triennial Congress of the International Ergonomics Association and 44th Annual Meeting of the Human Factors and Ergonomics Association, 'Ergonomics for the New Millennium'. 2000. p. 592-595
Jung, Eui Seung ; Woo, Bumyoung ; Yun, Myung. / A kinematic arm model based on the transverse elbow axis. Proceedings of the XIVth Triennial Congress of the International Ergonomics Association and 44th Annual Meeting of the Human Factors and Ergonomics Association, 'Ergonomics for the New Millennium'. 2000. pp. 592-595
@inproceedings{b9be83cee1674ffcb9e1e1f0d934d123,
title = "A kinematic arm model based on the transverse elbow axis",
abstract = "To determine the exact direction and location of the human joint in motion is crucial in developing an accurate human model. All the previous studies investigated, in vitro, the passive movement of the joint from cadavers and the suggested location of the joint axis was difficult to make practical applications due to the lack of the direction of joint axis. So, each joint axis has been assumed to lie horizontally or vertically to the adjacent links in many biomechanical models. In this study, the direction and location of the transverse elbow axis was obtained with respect to the global coordinate system whose origin is on the lateral epicondyle of the humerus. From the experiments conducted for five subjects, the direction and location of the transverse elbow axis was determined for each subject by the helical axis method. A statistical validation was also performed to confirm the result. The result was applied to develop an elbow model, which is apart of the kinematic arm model. The elbow model was developed to validate the significance of the result and the kinematic arm model was able to describe the geometry of any complex linkage system. As a result, the errors incurred from the proposed model were significantly reduced when compared to the ones from existing models.",
author = "Jung, {Eui Seung} and Bumyoung Woo and Myung Yun",
year = "2000",
month = "12",
day = "1",
language = "English",
pages = "592--595",
booktitle = "Proceedings of the XIVth Triennial Congress of the International Ergonomics Association and 44th Annual Meeting of the Human Factors and Ergonomics Association, 'Ergonomics for the New Millennium'",

}

TY - GEN

T1 - A kinematic arm model based on the transverse elbow axis

AU - Jung, Eui Seung

AU - Woo, Bumyoung

AU - Yun, Myung

PY - 2000/12/1

Y1 - 2000/12/1

N2 - To determine the exact direction and location of the human joint in motion is crucial in developing an accurate human model. All the previous studies investigated, in vitro, the passive movement of the joint from cadavers and the suggested location of the joint axis was difficult to make practical applications due to the lack of the direction of joint axis. So, each joint axis has been assumed to lie horizontally or vertically to the adjacent links in many biomechanical models. In this study, the direction and location of the transverse elbow axis was obtained with respect to the global coordinate system whose origin is on the lateral epicondyle of the humerus. From the experiments conducted for five subjects, the direction and location of the transverse elbow axis was determined for each subject by the helical axis method. A statistical validation was also performed to confirm the result. The result was applied to develop an elbow model, which is apart of the kinematic arm model. The elbow model was developed to validate the significance of the result and the kinematic arm model was able to describe the geometry of any complex linkage system. As a result, the errors incurred from the proposed model were significantly reduced when compared to the ones from existing models.

AB - To determine the exact direction and location of the human joint in motion is crucial in developing an accurate human model. All the previous studies investigated, in vitro, the passive movement of the joint from cadavers and the suggested location of the joint axis was difficult to make practical applications due to the lack of the direction of joint axis. So, each joint axis has been assumed to lie horizontally or vertically to the adjacent links in many biomechanical models. In this study, the direction and location of the transverse elbow axis was obtained with respect to the global coordinate system whose origin is on the lateral epicondyle of the humerus. From the experiments conducted for five subjects, the direction and location of the transverse elbow axis was determined for each subject by the helical axis method. A statistical validation was also performed to confirm the result. The result was applied to develop an elbow model, which is apart of the kinematic arm model. The elbow model was developed to validate the significance of the result and the kinematic arm model was able to describe the geometry of any complex linkage system. As a result, the errors incurred from the proposed model were significantly reduced when compared to the ones from existing models.

UR - http://www.scopus.com/inward/record.url?scp=1842710302&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=1842710302&partnerID=8YFLogxK

M3 - Conference contribution

SP - 592

EP - 595

BT - Proceedings of the XIVth Triennial Congress of the International Ergonomics Association and 44th Annual Meeting of the Human Factors and Ergonomics Association, 'Ergonomics for the New Millennium'

ER -