Abstract

Scattered radiation is the main reason for the degradation of image quality and the increased patient exposure dose in diagnostic radiology. In an effort to reduce scattered radiation, a novel structure of an indirect flat panel detector has been proposed. In this study, a performance evaluation of the novel system in terms of image contrast as well as an estimation of the number of photons incident on the detector and the grid exposure factor were conducted using Monte Carlo simulations. The image contrast of the proposed system was superior to that of the no-grid system but slightly inferior to that of the parallel-grid system. The number of photons incident on the detector and the grid exposure factor of the novel system were higher than those of the parallel-grid system but lower than those of the no-grid system. The proposed system exhibited the potential for reduced exposure dose without image quality degradation; additionally, can be further improved by a structural optimization considering the manufacturer's specifications of its lead contents.

Original languageEnglish
Article numberT10008
JournalJournal of Instrumentation
Volume11
Issue number10
DOIs
Publication statusPublished - 2016 Oct 19

Fingerprint

Radiation Detectors
Radiography
Radiation detectors
chest
radiation detectors
radiography
Performance Evaluation
Monte Carlo Simulation
grids
Radiation
Detectors
Image quality
evaluation
radiation
Photons
Grid
Degradation
Radiology
simulation
Structural optimization

Keywords

  • Detector modelling and simulations I (interaction of radiation with matter
  • etc)
  • interaction of hadrons with matter
  • interaction of photons with matter
  • X-ray radiography and digital radiography (DR)

ASJC Scopus subject areas

  • Instrumentation
  • Mathematical Physics

Cite this

A novel radiation detector for removing scattered radiation in chest radiography : Monte Carlo simulation-based performance evaluation. / Kim, Jung Min; Roh, Y. H.; Yoon, Y.; Kim, Kihyun; Kim, J.; Morishita, J.

In: Journal of Instrumentation, Vol. 11, No. 10, T10008, 19.10.2016.

Research output: Contribution to journalArticle

@article{33df47046c3649999c37e199ecbf0293,
title = "A novel radiation detector for removing scattered radiation in chest radiography: Monte Carlo simulation-based performance evaluation",
abstract = "Scattered radiation is the main reason for the degradation of image quality and the increased patient exposure dose in diagnostic radiology. In an effort to reduce scattered radiation, a novel structure of an indirect flat panel detector has been proposed. In this study, a performance evaluation of the novel system in terms of image contrast as well as an estimation of the number of photons incident on the detector and the grid exposure factor were conducted using Monte Carlo simulations. The image contrast of the proposed system was superior to that of the no-grid system but slightly inferior to that of the parallel-grid system. The number of photons incident on the detector and the grid exposure factor of the novel system were higher than those of the parallel-grid system but lower than those of the no-grid system. The proposed system exhibited the potential for reduced exposure dose without image quality degradation; additionally, can be further improved by a structural optimization considering the manufacturer's specifications of its lead contents.",
keywords = "Detector modelling and simulations I (interaction of radiation with matter, etc), interaction of hadrons with matter, interaction of photons with matter, X-ray radiography and digital radiography (DR)",
author = "Kim, {Jung Min} and Roh, {Y. H.} and Y. Yoon and Kihyun Kim and J. Kim and J. Morishita",
year = "2016",
month = "10",
day = "19",
doi = "10.1088/1748-0221/11/10/T10008",
language = "English",
volume = "11",
journal = "Journal of Instrumentation",
issn = "1748-0221",
publisher = "IOP Publishing Ltd.",
number = "10",

}

TY - JOUR

T1 - A novel radiation detector for removing scattered radiation in chest radiography

T2 - Monte Carlo simulation-based performance evaluation

AU - Kim, Jung Min

AU - Roh, Y. H.

AU - Yoon, Y.

AU - Kim, Kihyun

AU - Kim, J.

AU - Morishita, J.

PY - 2016/10/19

Y1 - 2016/10/19

N2 - Scattered radiation is the main reason for the degradation of image quality and the increased patient exposure dose in diagnostic radiology. In an effort to reduce scattered radiation, a novel structure of an indirect flat panel detector has been proposed. In this study, a performance evaluation of the novel system in terms of image contrast as well as an estimation of the number of photons incident on the detector and the grid exposure factor were conducted using Monte Carlo simulations. The image contrast of the proposed system was superior to that of the no-grid system but slightly inferior to that of the parallel-grid system. The number of photons incident on the detector and the grid exposure factor of the novel system were higher than those of the parallel-grid system but lower than those of the no-grid system. The proposed system exhibited the potential for reduced exposure dose without image quality degradation; additionally, can be further improved by a structural optimization considering the manufacturer's specifications of its lead contents.

AB - Scattered radiation is the main reason for the degradation of image quality and the increased patient exposure dose in diagnostic radiology. In an effort to reduce scattered radiation, a novel structure of an indirect flat panel detector has been proposed. In this study, a performance evaluation of the novel system in terms of image contrast as well as an estimation of the number of photons incident on the detector and the grid exposure factor were conducted using Monte Carlo simulations. The image contrast of the proposed system was superior to that of the no-grid system but slightly inferior to that of the parallel-grid system. The number of photons incident on the detector and the grid exposure factor of the novel system were higher than those of the parallel-grid system but lower than those of the no-grid system. The proposed system exhibited the potential for reduced exposure dose without image quality degradation; additionally, can be further improved by a structural optimization considering the manufacturer's specifications of its lead contents.

KW - Detector modelling and simulations I (interaction of radiation with matter

KW - etc)

KW - interaction of hadrons with matter

KW - interaction of photons with matter

KW - X-ray radiography and digital radiography (DR)

UR - http://www.scopus.com/inward/record.url?scp=85068514498&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85068514498&partnerID=8YFLogxK

U2 - 10.1088/1748-0221/11/10/T10008

DO - 10.1088/1748-0221/11/10/T10008

M3 - Article

VL - 11

JO - Journal of Instrumentation

JF - Journal of Instrumentation

SN - 1748-0221

IS - 10

M1 - T10008

ER -