A novel SIME configuration scheme correlating generator tripping for transient stability assessment

Seung Chan Oh, Hwan Ik Lee, Yun Hwan Lee, Byong Jun Lee

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

When a contingency occurs in a large transmission route in a power system, it can generate various instabilities that may lead to a power system blackout. In particular, transient instability in a power system needs to be immediately addressed, and preventive measures should be in place prior to fault occurrence. Measures to achieve transient stability include system reinforcement, power generation restriction, and generator tripping. Because the interpretation of transient stability is a time domain simulation, it is difficult to determine the efficacy of proposed countermeasures using only simple simulation results. Therefore, several methods to quantify transient stability have been introduced. Among them, the single machine equivalent (SIME) method based on the equal area criterion (EAC) can quantify the degree of instability by calculating the residual acceleration energy of a generator. However, method for generator tripping effect evaluation does not have been established. In this study, we propose a method to evaluate the effect of generator tripping on transient stability that is based on the SIME method. For this purpose, the measures that reflect generator tripping in the SIME calculation are reviewed. Simulation results obtained by applying the proposed method to the IEEE 39-bus system and KEPCO system are then presented.

Original languageEnglish
Pages (from-to)1798-1806
Number of pages9
JournalJournal of Electrical Engineering and Technology
Volume13
Issue number5
DOIs
Publication statusPublished - 2018 Sep 1

Fingerprint

Power generation
Reinforcement

Keywords

  • Generator tripping
  • Power system stability
  • SIME method
  • Transient stability assessment
  • Transient stability margin

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Cite this

A novel SIME configuration scheme correlating generator tripping for transient stability assessment. / Oh, Seung Chan; Lee, Hwan Ik; Lee, Yun Hwan; Lee, Byong Jun.

In: Journal of Electrical Engineering and Technology, Vol. 13, No. 5, 01.09.2018, p. 1798-1806.

Research output: Contribution to journalArticle

@article{126084d40a5b4c889ae7bb2085f20074,
title = "A novel SIME configuration scheme correlating generator tripping for transient stability assessment",
abstract = "When a contingency occurs in a large transmission route in a power system, it can generate various instabilities that may lead to a power system blackout. In particular, transient instability in a power system needs to be immediately addressed, and preventive measures should be in place prior to fault occurrence. Measures to achieve transient stability include system reinforcement, power generation restriction, and generator tripping. Because the interpretation of transient stability is a time domain simulation, it is difficult to determine the efficacy of proposed countermeasures using only simple simulation results. Therefore, several methods to quantify transient stability have been introduced. Among them, the single machine equivalent (SIME) method based on the equal area criterion (EAC) can quantify the degree of instability by calculating the residual acceleration energy of a generator. However, method for generator tripping effect evaluation does not have been established. In this study, we propose a method to evaluate the effect of generator tripping on transient stability that is based on the SIME method. For this purpose, the measures that reflect generator tripping in the SIME calculation are reviewed. Simulation results obtained by applying the proposed method to the IEEE 39-bus system and KEPCO system are then presented.",
keywords = "Generator tripping, Power system stability, SIME method, Transient stability assessment, Transient stability margin",
author = "Oh, {Seung Chan} and Lee, {Hwan Ik} and Lee, {Yun Hwan} and Lee, {Byong Jun}",
year = "2018",
month = "9",
day = "1",
doi = "10.5370/JEET.2018.13.5.1798",
language = "English",
volume = "13",
pages = "1798--1806",
journal = "Journal of Electrical Engineering and Technology",
issn = "1975-0102",
publisher = "Korean Institute of Electrical Engineers",
number = "5",

}

TY - JOUR

T1 - A novel SIME configuration scheme correlating generator tripping for transient stability assessment

AU - Oh, Seung Chan

AU - Lee, Hwan Ik

AU - Lee, Yun Hwan

AU - Lee, Byong Jun

PY - 2018/9/1

Y1 - 2018/9/1

N2 - When a contingency occurs in a large transmission route in a power system, it can generate various instabilities that may lead to a power system blackout. In particular, transient instability in a power system needs to be immediately addressed, and preventive measures should be in place prior to fault occurrence. Measures to achieve transient stability include system reinforcement, power generation restriction, and generator tripping. Because the interpretation of transient stability is a time domain simulation, it is difficult to determine the efficacy of proposed countermeasures using only simple simulation results. Therefore, several methods to quantify transient stability have been introduced. Among them, the single machine equivalent (SIME) method based on the equal area criterion (EAC) can quantify the degree of instability by calculating the residual acceleration energy of a generator. However, method for generator tripping effect evaluation does not have been established. In this study, we propose a method to evaluate the effect of generator tripping on transient stability that is based on the SIME method. For this purpose, the measures that reflect generator tripping in the SIME calculation are reviewed. Simulation results obtained by applying the proposed method to the IEEE 39-bus system and KEPCO system are then presented.

AB - When a contingency occurs in a large transmission route in a power system, it can generate various instabilities that may lead to a power system blackout. In particular, transient instability in a power system needs to be immediately addressed, and preventive measures should be in place prior to fault occurrence. Measures to achieve transient stability include system reinforcement, power generation restriction, and generator tripping. Because the interpretation of transient stability is a time domain simulation, it is difficult to determine the efficacy of proposed countermeasures using only simple simulation results. Therefore, several methods to quantify transient stability have been introduced. Among them, the single machine equivalent (SIME) method based on the equal area criterion (EAC) can quantify the degree of instability by calculating the residual acceleration energy of a generator. However, method for generator tripping effect evaluation does not have been established. In this study, we propose a method to evaluate the effect of generator tripping on transient stability that is based on the SIME method. For this purpose, the measures that reflect generator tripping in the SIME calculation are reviewed. Simulation results obtained by applying the proposed method to the IEEE 39-bus system and KEPCO system are then presented.

KW - Generator tripping

KW - Power system stability

KW - SIME method

KW - Transient stability assessment

KW - Transient stability margin

UR - http://www.scopus.com/inward/record.url?scp=85052147172&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85052147172&partnerID=8YFLogxK

U2 - 10.5370/JEET.2018.13.5.1798

DO - 10.5370/JEET.2018.13.5.1798

M3 - Article

AN - SCOPUS:85052147172

VL - 13

SP - 1798

EP - 1806

JO - Journal of Electrical Engineering and Technology

JF - Journal of Electrical Engineering and Technology

SN - 1975-0102

IS - 5