T1 - A simple novel endoscopic successive suture device
T2 - A validation study for closure strength and reproducibility
AU - Song, Y.
AU - Choi, H. S.
AU - Kim, K.
AU - Kim, Y.
AU - Kim, B. G.
AU - Hong, D.
AU - Keum, B.
AU - Chun, H. J.
PY - 2013
Y1 - 2013
N2 - Background and study aims: Endoscopic surgical technology has been developing rapidly. Although several successful endoscopic closure devices have already been introduced, only a few of them have demonstrated improvements in closure strength and reproducibility over conventional endoscopic clip closures or hand sutures. The objective of this study was to test the feasibility of a novel successive suturing device (SSD) by measuring closure strength and reproducibility. Material and methods: Porcine stomach models were used in this study. Endoclips, full-thickness hand sutures, and the novel SSD sutures were used to close a perforation in the stomach wall, with 10 stomachs being tested for each closure method. Endoclips and SSD sutures were performed using a two-channel endoscope, and the hand sutures were performed from outside of the stomach wall. Air leakage pressure was measured to determine the closure strength and reproducibility of each method. Results: The mean air leakage pressure of the SSD closure was 62.7 ± 8.2 mmHg. SSD-treated stomachs exhibited significantly greater air leakage pressure than Endoclip-treated stomachs. The standard deviation of bursting pressure in SSD stomachs was found to be significantly smaller than that of hand-sewn stomachs but was not different from that of Endoclip stomachs. Conclusions: The consistent closure strength of SSD stomachs demonstrated the reliability and reproducibility of this new closure method. These promising results in closure strength and reproducibility suggest the feasibility of the proposed device for clinical applications.
AB - Background and study aims: Endoscopic surgical technology has been developing rapidly. Although several successful endoscopic closure devices have already been introduced, only a few of them have demonstrated improvements in closure strength and reproducibility over conventional endoscopic clip closures or hand sutures. The objective of this study was to test the feasibility of a novel successive suturing device (SSD) by measuring closure strength and reproducibility. Material and methods: Porcine stomach models were used in this study. Endoclips, full-thickness hand sutures, and the novel SSD sutures were used to close a perforation in the stomach wall, with 10 stomachs being tested for each closure method. Endoclips and SSD sutures were performed using a two-channel endoscope, and the hand sutures were performed from outside of the stomach wall. Air leakage pressure was measured to determine the closure strength and reproducibility of each method. Results: The mean air leakage pressure of the SSD closure was 62.7 ± 8.2 mmHg. SSD-treated stomachs exhibited significantly greater air leakage pressure than Endoclip-treated stomachs. The standard deviation of bursting pressure in SSD stomachs was found to be significantly smaller than that of hand-sewn stomachs but was not different from that of Endoclip stomachs. Conclusions: The consistent closure strength of SSD stomachs demonstrated the reliability and reproducibility of this new closure method. These promising results in closure strength and reproducibility suggest the feasibility of the proposed device for clinical applications.
UR - http://www.scopus.com/inward/record.url?scp=84880835930&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84880835930&partnerID=8YFLogxK
U2 - 10.1055/s-0033-1344214
DO - 10.1055/s-0033-1344214
M3 - Article
C2 - 23881806
AN - SCOPUS:84880835930
SN - 0013-726X
VL - 45
SP - 655
EP - 660
JO - Endoscopy
JF - Endoscopy
IS - 8
ER -