A stator-core quality-assessment technique for inverter-fed induction machines

Kwanghwan Lee, Jongman Hong, Kwang Woon Lee, Sang Bin Lee, Ernesto J. Wiedenbrug

Research output: Contribution to journalArticle

15 Citations (Scopus)

Abstract

Localized heating caused by damage in the laminations or interlaminar insulation of the stator core increases the core losses and can lead to machine failure. Therefore, it is important to monitor the quality of the stator core for reliable and efficient operation of the machine. The methods currently available for core quality assessment are inconvenient since they require an outage and the machine to be disassembled or operated under no-load conditions. In this paper, a new method for monitoring the quality of the stator core for inverter-fed machines without motor disassembly or operation is proposed. The main concept is to use the inverter to apply a set of test signals to assess the quality of the core whenever the motor is at standstill. A set of high-frequency pulsating magnetic fields is produced using the inverter, and the power loss is observed as a function of field circumferential position to detect core problems. An experimental study on a 10-hp induction motor verifies that local interlaminar core faults can be detected with high sensitivity. The proposed technique is expected to provide a simple solution for frequent stator-core quality assessment without motor disassembly, motor operation, or additional hardware for reliable and efficient operation of inverter-fed induction machines.

Original languageEnglish
Article number5339137
Pages (from-to)213-221
Number of pages9
JournalIEEE Transactions on Industry Applications
Volume46
Issue number1
DOIs
Publication statusPublished - 2010 Jan 1

Fingerprint

Stators
Outages
Induction motors
Insulation
Magnetic fields
Hardware
Heating
Monitoring

Keywords

  • AC machine
  • Condition monitoring
  • Core loss
  • Diagnostics
  • Eddy-current loss
  • Hysteresis loss
  • Induction motor
  • Interlaminar-insulation failure
  • Inverter
  • Stator core

ASJC Scopus subject areas

  • Control and Systems Engineering
  • Electrical and Electronic Engineering
  • Industrial and Manufacturing Engineering

Cite this

A stator-core quality-assessment technique for inverter-fed induction machines. / Lee, Kwanghwan; Hong, Jongman; Lee, Kwang Woon; Lee, Sang Bin; Wiedenbrug, Ernesto J.

In: IEEE Transactions on Industry Applications, Vol. 46, No. 1, 5339137, 01.01.2010, p. 213-221.

Research output: Contribution to journalArticle

Lee, Kwanghwan ; Hong, Jongman ; Lee, Kwang Woon ; Lee, Sang Bin ; Wiedenbrug, Ernesto J. / A stator-core quality-assessment technique for inverter-fed induction machines. In: IEEE Transactions on Industry Applications. 2010 ; Vol. 46, No. 1. pp. 213-221.
@article{d0d8cfbb5ec64ae6be96a147cf94a437,
title = "A stator-core quality-assessment technique for inverter-fed induction machines",
abstract = "Localized heating caused by damage in the laminations or interlaminar insulation of the stator core increases the core losses and can lead to machine failure. Therefore, it is important to monitor the quality of the stator core for reliable and efficient operation of the machine. The methods currently available for core quality assessment are inconvenient since they require an outage and the machine to be disassembled or operated under no-load conditions. In this paper, a new method for monitoring the quality of the stator core for inverter-fed machines without motor disassembly or operation is proposed. The main concept is to use the inverter to apply a set of test signals to assess the quality of the core whenever the motor is at standstill. A set of high-frequency pulsating magnetic fields is produced using the inverter, and the power loss is observed as a function of field circumferential position to detect core problems. An experimental study on a 10-hp induction motor verifies that local interlaminar core faults can be detected with high sensitivity. The proposed technique is expected to provide a simple solution for frequent stator-core quality assessment without motor disassembly, motor operation, or additional hardware for reliable and efficient operation of inverter-fed induction machines.",
keywords = "AC machine, Condition monitoring, Core loss, Diagnostics, Eddy-current loss, Hysteresis loss, Induction motor, Interlaminar-insulation failure, Inverter, Stator core",
author = "Kwanghwan Lee and Jongman Hong and Lee, {Kwang Woon} and Lee, {Sang Bin} and Wiedenbrug, {Ernesto J.}",
year = "2010",
month = "1",
day = "1",
doi = "10.1109/TIA.2009.2036527",
language = "English",
volume = "46",
pages = "213--221",
journal = "IEEE Transactions on Industry Applications",
issn = "0093-9994",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "1",

}

TY - JOUR

T1 - A stator-core quality-assessment technique for inverter-fed induction machines

AU - Lee, Kwanghwan

AU - Hong, Jongman

AU - Lee, Kwang Woon

AU - Lee, Sang Bin

AU - Wiedenbrug, Ernesto J.

PY - 2010/1/1

Y1 - 2010/1/1

N2 - Localized heating caused by damage in the laminations or interlaminar insulation of the stator core increases the core losses and can lead to machine failure. Therefore, it is important to monitor the quality of the stator core for reliable and efficient operation of the machine. The methods currently available for core quality assessment are inconvenient since they require an outage and the machine to be disassembled or operated under no-load conditions. In this paper, a new method for monitoring the quality of the stator core for inverter-fed machines without motor disassembly or operation is proposed. The main concept is to use the inverter to apply a set of test signals to assess the quality of the core whenever the motor is at standstill. A set of high-frequency pulsating magnetic fields is produced using the inverter, and the power loss is observed as a function of field circumferential position to detect core problems. An experimental study on a 10-hp induction motor verifies that local interlaminar core faults can be detected with high sensitivity. The proposed technique is expected to provide a simple solution for frequent stator-core quality assessment without motor disassembly, motor operation, or additional hardware for reliable and efficient operation of inverter-fed induction machines.

AB - Localized heating caused by damage in the laminations or interlaminar insulation of the stator core increases the core losses and can lead to machine failure. Therefore, it is important to monitor the quality of the stator core for reliable and efficient operation of the machine. The methods currently available for core quality assessment are inconvenient since they require an outage and the machine to be disassembled or operated under no-load conditions. In this paper, a new method for monitoring the quality of the stator core for inverter-fed machines without motor disassembly or operation is proposed. The main concept is to use the inverter to apply a set of test signals to assess the quality of the core whenever the motor is at standstill. A set of high-frequency pulsating magnetic fields is produced using the inverter, and the power loss is observed as a function of field circumferential position to detect core problems. An experimental study on a 10-hp induction motor verifies that local interlaminar core faults can be detected with high sensitivity. The proposed technique is expected to provide a simple solution for frequent stator-core quality assessment without motor disassembly, motor operation, or additional hardware for reliable and efficient operation of inverter-fed induction machines.

KW - AC machine

KW - Condition monitoring

KW - Core loss

KW - Diagnostics

KW - Eddy-current loss

KW - Hysteresis loss

KW - Induction motor

KW - Interlaminar-insulation failure

KW - Inverter

KW - Stator core

UR - http://www.scopus.com/inward/record.url?scp=76249121151&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=76249121151&partnerID=8YFLogxK

U2 - 10.1109/TIA.2009.2036527

DO - 10.1109/TIA.2009.2036527

M3 - Article

AN - SCOPUS:76249121151

VL - 46

SP - 213

EP - 221

JO - IEEE Transactions on Industry Applications

JF - IEEE Transactions on Industry Applications

SN - 0093-9994

IS - 1

M1 - 5339137

ER -