Through the development of phasor measurement units (PMU), various aspects of power system dynamic behavior could be monitored and diagnosed. Monitoring dynamic Voltage stability becomes one of achievements we can obtain from PMUs. It is very important to select the method appropriate to the KEPCO system since there are many voltage stability indices. In the paper, we propose an advanced WAVI (Wide Area Voltage Stability) for monitoring dynamic voltage stability. It reflects the PMU installation plan of KEPCO, thus it is suitable for KEPCO system specially. The salient features of the proposed index are; i) it uses only PMU measurements without coupling with EMS data, ii) it is computationally. unburden so that it can be applied to real-time situation. The proposed index is applied to the KEPCO test system and the result shows that it successfully predicts voltage instability through the comparative studies.

Original languageEnglish
Pages (from-to)2328-2334
Number of pages7
JournalTransactions of the Korean Institute of Electrical Engineers
Volume58
Issue number12
Publication statusPublished - 2009 Dec 1

Fingerprint

Phasor measurement units
Voltage control
Monitoring
Dynamical systems
Electric potential

Keywords

  • PMU
  • Real-Time
  • Voltage Stability
  • Wide Area Voltage Stability Index(WAVI)

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Cite this

A voltage stability monitoring algorithm using a few PMUs in metropolitan area. / Han, Sangwook; Lee, Byong Jun.

In: Transactions of the Korean Institute of Electrical Engineers, Vol. 58, No. 12, 01.12.2009, p. 2328-2334.

Research output: Contribution to journalArticle

@article{448b9c39829144fb965516e6c1c636db,
title = "A voltage stability monitoring algorithm using a few PMUs in metropolitan area",
abstract = "Through the development of phasor measurement units (PMU), various aspects of power system dynamic behavior could be monitored and diagnosed. Monitoring dynamic Voltage stability becomes one of achievements we can obtain from PMUs. It is very important to select the method appropriate to the KEPCO system since there are many voltage stability indices. In the paper, we propose an advanced WAVI (Wide Area Voltage Stability) for monitoring dynamic voltage stability. It reflects the PMU installation plan of KEPCO, thus it is suitable for KEPCO system specially. The salient features of the proposed index are; i) it uses only PMU measurements without coupling with EMS data, ii) it is computationally. unburden so that it can be applied to real-time situation. The proposed index is applied to the KEPCO test system and the result shows that it successfully predicts voltage instability through the comparative studies.",
keywords = "PMU, Real-Time, Voltage Stability, Wide Area Voltage Stability Index(WAVI)",
author = "Sangwook Han and Lee, {Byong Jun}",
year = "2009",
month = "12",
day = "1",
language = "English",
volume = "58",
pages = "2328--2334",
journal = "Transactions of the Korean Institute of Electrical Engineers",
issn = "1975-8359",
publisher = "Korean Institute of Electrical Engineers",
number = "12",

}

TY - JOUR

T1 - A voltage stability monitoring algorithm using a few PMUs in metropolitan area

AU - Han, Sangwook

AU - Lee, Byong Jun

PY - 2009/12/1

Y1 - 2009/12/1

N2 - Through the development of phasor measurement units (PMU), various aspects of power system dynamic behavior could be monitored and diagnosed. Monitoring dynamic Voltage stability becomes one of achievements we can obtain from PMUs. It is very important to select the method appropriate to the KEPCO system since there are many voltage stability indices. In the paper, we propose an advanced WAVI (Wide Area Voltage Stability) for monitoring dynamic voltage stability. It reflects the PMU installation plan of KEPCO, thus it is suitable for KEPCO system specially. The salient features of the proposed index are; i) it uses only PMU measurements without coupling with EMS data, ii) it is computationally. unburden so that it can be applied to real-time situation. The proposed index is applied to the KEPCO test system and the result shows that it successfully predicts voltage instability through the comparative studies.

AB - Through the development of phasor measurement units (PMU), various aspects of power system dynamic behavior could be monitored and diagnosed. Monitoring dynamic Voltage stability becomes one of achievements we can obtain from PMUs. It is very important to select the method appropriate to the KEPCO system since there are many voltage stability indices. In the paper, we propose an advanced WAVI (Wide Area Voltage Stability) for monitoring dynamic voltage stability. It reflects the PMU installation plan of KEPCO, thus it is suitable for KEPCO system specially. The salient features of the proposed index are; i) it uses only PMU measurements without coupling with EMS data, ii) it is computationally. unburden so that it can be applied to real-time situation. The proposed index is applied to the KEPCO test system and the result shows that it successfully predicts voltage instability through the comparative studies.

KW - PMU

KW - Real-Time

KW - Voltage Stability

KW - Wide Area Voltage Stability Index(WAVI)

UR - http://www.scopus.com/inward/record.url?scp=73249119739&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=73249119739&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:73249119739

VL - 58

SP - 2328

EP - 2334

JO - Transactions of the Korean Institute of Electrical Engineers

JF - Transactions of the Korean Institute of Electrical Engineers

SN - 1975-8359

IS - 12

ER -