TY - JOUR
T1 - Accuracy and Efficiency of Right-Lobe Graft Weight Estimation Using Deep-Learning-Assisted CT Volumetry for Living-Donor Liver Transplantation
AU - Park, Rohee
AU - Lee, Seungsoo
AU - Sung, Yusub
AU - Yoon, Jeeseok
AU - Suk, Heung Il
AU - Kim, Hyoungjung
AU - Choi, Sanghyun
N1 - Funding Information:
Funding: This research was supported by a National Research Foundation of Korea (NRF) grant, funded by the Korean government (MSIT) (2020R1F1A1048826).
Publisher Copyright:
© 2022 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2022/3
Y1 - 2022/3
N2 - CT volumetry (CTV) has been widely used for pre-operative graft weight (GW) estimation in living-donor liver transplantation (LDLT), and the use of a deep-learning algorithm (DLA) may further improve its efficiency. However, its accuracy has not been well determined. To evaluate the efficiency and accuracy of DLA-assisted CTV in GW estimation, we performed a retrospective study including 581 consecutive LDLT donors who donated a right-lobe graft. Right-lobe graft volume (GV) was measured on CT using the software implemented with the DLA for automated liver segmentation. In the development group (n = 207), a volume-to-weight conversion formula was constructed by linear regression analysis between the CTV-measured GV and the intraoperative GW. In the validation group (n = 374), the agreement between the estimated and measured GWs was assessed using the Bland–Altman 95% limit-of-agreement (LOA). The mean process time for GV measurement was 1.8 ± 0.6 min (range, 1.3–8.0 min). In the validation group, the GW was estimated using the volume-to-weight conversion formula (estimated GW [g] = 206.3 + 0.653 × CTV-measured GV [mL]), and the Bland–Altman 95% LOA between the estimated and measured GWs was −1.7% ± 17.1%. The DLA-assisted CT volumetry allows for time-efficient and accurate estimation of GW in LDLT.
AB - CT volumetry (CTV) has been widely used for pre-operative graft weight (GW) estimation in living-donor liver transplantation (LDLT), and the use of a deep-learning algorithm (DLA) may further improve its efficiency. However, its accuracy has not been well determined. To evaluate the efficiency and accuracy of DLA-assisted CTV in GW estimation, we performed a retrospective study including 581 consecutive LDLT donors who donated a right-lobe graft. Right-lobe graft volume (GV) was measured on CT using the software implemented with the DLA for automated liver segmentation. In the development group (n = 207), a volume-to-weight conversion formula was constructed by linear regression analysis between the CTV-measured GV and the intraoperative GW. In the validation group (n = 374), the agreement between the estimated and measured GWs was assessed using the Bland–Altman 95% limit-of-agreement (LOA). The mean process time for GV measurement was 1.8 ± 0.6 min (range, 1.3–8.0 min). In the validation group, the GW was estimated using the volume-to-weight conversion formula (estimated GW [g] = 206.3 + 0.653 × CTV-measured GV [mL]), and the Bland–Altman 95% LOA between the estimated and measured GWs was −1.7% ± 17.1%. The DLA-assisted CT volumetry allows for time-efficient and accurate estimation of GW in LDLT.
KW - CT volumetry
KW - Deep learning
KW - Living right liver donors
KW - Segmentation
UR - http://www.scopus.com/inward/record.url?scp=85125616198&partnerID=8YFLogxK
U2 - 10.3390/diagnostics12030590
DO - 10.3390/diagnostics12030590
M3 - Article
AN - SCOPUS:85125616198
SN - 2075-4418
VL - 12
JO - Diagnostics
JF - Diagnostics
IS - 3
M1 - 590
ER -