This paper reports the pre-concentration of C-reactive protein (CRP) antigen with packed beads in a microfluidic chamber to enhance the sensitivity of the miniaturized fluorescence detection system for portable point-of-care testing devices. Although integrated optical systems in microfluidic chips have been demonstrated by many groups to replace bulky optical systems, the problem of low sensitivity is a hurdle for on-site clinical applications. Hence we integrated the pre-concentration module with miniaturized detection in microfluidic chips (MDMC) to improve analytical sensitivity. Cheap silicon-based photodiodes with optical filter were packaged in PDMS microfluidic chips and beads were packed by a frit structure for pre-concentration. The beads were coated with CRP antibodies to capture antigens and the concentrated antigens were eluted by an acid buffer. The pre-concentration amplified the fluorescence intensity by about 20-fold and the fluorescence signal was linearly proportional to the concentration of antigens. Then the CRP antigen was analyzed by competitive immunoassay with an MDMC. The experimental result demonstrated that the analytical sensitivity was enhanced up to 1.4 nM owing to the higher signal-to-noise ratio. The amplification of fluorescence by pre-concentration of bead-based immunoassay is expected to be one of the methods for portable fluorescence detection system.

Original languageEnglish
Pages (from-to)2261-2267
Number of pages7
JournalBiosensors and Bioelectronics
Volume22
Issue number9-10
DOIs
Publication statusPublished - 2007 Apr 15

Fingerprint

Microfluidics
Antigens
Amplification
Fluorescence
C-Reactive Protein
Optical Devices
Proteins
Immunoassay
Optical systems
Optical filters
Signal-To-Noise Ratio
Silicon
Photodiodes
Antibodies
Signal to noise ratio
Buffers
Equipment and Supplies
Acids
Testing

Keywords

  • Beads
  • Fluorescence detection
  • Immunoassay
  • Photodiode
  • Pre-concentration

ASJC Scopus subject areas

  • Biotechnology
  • Analytical Chemistry
  • Electrochemistry

Cite this

Amplification of fluorescence with packed beads to enhance the sensitivity of miniaturized detection in microfluidic chip. / Shin, Kyeong S.; Lee, Sung Woo; Han, Ki Cheol; Kim, Sang Kyung; Yang, Eun Kyung; Park, Jung ho; Ju, Byeong Kwon; Kang, Ji Yoon; Kim, Tae Song.

In: Biosensors and Bioelectronics, Vol. 22, No. 9-10, 15.04.2007, p. 2261-2267.

Research output: Contribution to journalArticle

Shin, Kyeong S. ; Lee, Sung Woo ; Han, Ki Cheol ; Kim, Sang Kyung ; Yang, Eun Kyung ; Park, Jung ho ; Ju, Byeong Kwon ; Kang, Ji Yoon ; Kim, Tae Song. / Amplification of fluorescence with packed beads to enhance the sensitivity of miniaturized detection in microfluidic chip. In: Biosensors and Bioelectronics. 2007 ; Vol. 22, No. 9-10. pp. 2261-2267.
@article{101d26e48c6d4bc98ed03769e7deb9ec,
title = "Amplification of fluorescence with packed beads to enhance the sensitivity of miniaturized detection in microfluidic chip",
abstract = "This paper reports the pre-concentration of C-reactive protein (CRP) antigen with packed beads in a microfluidic chamber to enhance the sensitivity of the miniaturized fluorescence detection system for portable point-of-care testing devices. Although integrated optical systems in microfluidic chips have been demonstrated by many groups to replace bulky optical systems, the problem of low sensitivity is a hurdle for on-site clinical applications. Hence we integrated the pre-concentration module with miniaturized detection in microfluidic chips (MDMC) to improve analytical sensitivity. Cheap silicon-based photodiodes with optical filter were packaged in PDMS microfluidic chips and beads were packed by a frit structure for pre-concentration. The beads were coated with CRP antibodies to capture antigens and the concentrated antigens were eluted by an acid buffer. The pre-concentration amplified the fluorescence intensity by about 20-fold and the fluorescence signal was linearly proportional to the concentration of antigens. Then the CRP antigen was analyzed by competitive immunoassay with an MDMC. The experimental result demonstrated that the analytical sensitivity was enhanced up to 1.4 nM owing to the higher signal-to-noise ratio. The amplification of fluorescence by pre-concentration of bead-based immunoassay is expected to be one of the methods for portable fluorescence detection system.",
keywords = "Beads, Fluorescence detection, Immunoassay, Photodiode, Pre-concentration",
author = "Shin, {Kyeong S.} and Lee, {Sung Woo} and Han, {Ki Cheol} and Kim, {Sang Kyung} and Yang, {Eun Kyung} and Park, {Jung ho} and Ju, {Byeong Kwon} and Kang, {Ji Yoon} and Kim, {Tae Song}",
year = "2007",
month = "4",
day = "15",
doi = "10.1016/j.bios.2006.11.011",
language = "English",
volume = "22",
pages = "2261--2267",
journal = "Biosensors",
issn = "0956-5663",
publisher = "Elsevier Limited",
number = "9-10",

}

TY - JOUR

T1 - Amplification of fluorescence with packed beads to enhance the sensitivity of miniaturized detection in microfluidic chip

AU - Shin, Kyeong S.

AU - Lee, Sung Woo

AU - Han, Ki Cheol

AU - Kim, Sang Kyung

AU - Yang, Eun Kyung

AU - Park, Jung ho

AU - Ju, Byeong Kwon

AU - Kang, Ji Yoon

AU - Kim, Tae Song

PY - 2007/4/15

Y1 - 2007/4/15

N2 - This paper reports the pre-concentration of C-reactive protein (CRP) antigen with packed beads in a microfluidic chamber to enhance the sensitivity of the miniaturized fluorescence detection system for portable point-of-care testing devices. Although integrated optical systems in microfluidic chips have been demonstrated by many groups to replace bulky optical systems, the problem of low sensitivity is a hurdle for on-site clinical applications. Hence we integrated the pre-concentration module with miniaturized detection in microfluidic chips (MDMC) to improve analytical sensitivity. Cheap silicon-based photodiodes with optical filter were packaged in PDMS microfluidic chips and beads were packed by a frit structure for pre-concentration. The beads were coated with CRP antibodies to capture antigens and the concentrated antigens were eluted by an acid buffer. The pre-concentration amplified the fluorescence intensity by about 20-fold and the fluorescence signal was linearly proportional to the concentration of antigens. Then the CRP antigen was analyzed by competitive immunoassay with an MDMC. The experimental result demonstrated that the analytical sensitivity was enhanced up to 1.4 nM owing to the higher signal-to-noise ratio. The amplification of fluorescence by pre-concentration of bead-based immunoassay is expected to be one of the methods for portable fluorescence detection system.

AB - This paper reports the pre-concentration of C-reactive protein (CRP) antigen with packed beads in a microfluidic chamber to enhance the sensitivity of the miniaturized fluorescence detection system for portable point-of-care testing devices. Although integrated optical systems in microfluidic chips have been demonstrated by many groups to replace bulky optical systems, the problem of low sensitivity is a hurdle for on-site clinical applications. Hence we integrated the pre-concentration module with miniaturized detection in microfluidic chips (MDMC) to improve analytical sensitivity. Cheap silicon-based photodiodes with optical filter were packaged in PDMS microfluidic chips and beads were packed by a frit structure for pre-concentration. The beads were coated with CRP antibodies to capture antigens and the concentrated antigens were eluted by an acid buffer. The pre-concentration amplified the fluorescence intensity by about 20-fold and the fluorescence signal was linearly proportional to the concentration of antigens. Then the CRP antigen was analyzed by competitive immunoassay with an MDMC. The experimental result demonstrated that the analytical sensitivity was enhanced up to 1.4 nM owing to the higher signal-to-noise ratio. The amplification of fluorescence by pre-concentration of bead-based immunoassay is expected to be one of the methods for portable fluorescence detection system.

KW - Beads

KW - Fluorescence detection

KW - Immunoassay

KW - Photodiode

KW - Pre-concentration

UR - http://www.scopus.com/inward/record.url?scp=33847370217&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33847370217&partnerID=8YFLogxK

U2 - 10.1016/j.bios.2006.11.011

DO - 10.1016/j.bios.2006.11.011

M3 - Article

VL - 22

SP - 2261

EP - 2267

JO - Biosensors

JF - Biosensors

SN - 0956-5663

IS - 9-10

ER -