An approach to improve the penetration of sustainable energy using optimal transformer tap control

Moonsung Bae, Hwanik Lee, Byong Jun Lee

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

A method to secure the generator reactive power reserve by adjusting the transformer tap to improve the power system penetration of renewable energy has been proposed in this study. The tap is adjusted based on the voltage and reactive power sensitivity in the power system network. That is, the transformer tap sensitivity is calculated and analyzed to adjust the tap variation to gain sufficient or the least necessary amount of reactive power reserve. This method can be effective for generators without any margins in the reserves. The optimization problem based on the calculated sensitivities and effectiveness are presented. The optimum solution derived from such a problem provides the minimum control amount necessary to maintain the system voltage and dynamic reactive power reserve at their pre-specified levels to improve the power system acceptability of renewable energy. To demonstrate the effectiveness of the method proposed, a simulation has been performed for an IEEE-25 bus system. The results from simulations prove that the voltage has been well maintained while securing a dynamic reactive power reserve through optimal control based on the sensitivity analysis.

Original languageEnglish
Article number1536
JournalSustainability (Switzerland)
Volume9
Issue number9
DOIs
Publication statusPublished - 2017 Aug 30

Fingerprint

Reactive power
penetration
energy
renewable energy
Electric potential
simulation
Sensitivity analysis
sensitivity analysis
method

Keywords

  • On-load tap-changers
  • Reactive power reserve
  • Sensitivity analysis
  • Sustainable energy penetration

ASJC Scopus subject areas

  • Geography, Planning and Development
  • Renewable Energy, Sustainability and the Environment
  • Management, Monitoring, Policy and Law

Cite this

An approach to improve the penetration of sustainable energy using optimal transformer tap control. / Bae, Moonsung; Lee, Hwanik; Lee, Byong Jun.

In: Sustainability (Switzerland), Vol. 9, No. 9, 1536, 30.08.2017.

Research output: Contribution to journalArticle

@article{6f9111f266b0415d9059a86de6e6f081,
title = "An approach to improve the penetration of sustainable energy using optimal transformer tap control",
abstract = "A method to secure the generator reactive power reserve by adjusting the transformer tap to improve the power system penetration of renewable energy has been proposed in this study. The tap is adjusted based on the voltage and reactive power sensitivity in the power system network. That is, the transformer tap sensitivity is calculated and analyzed to adjust the tap variation to gain sufficient or the least necessary amount of reactive power reserve. This method can be effective for generators without any margins in the reserves. The optimization problem based on the calculated sensitivities and effectiveness are presented. The optimum solution derived from such a problem provides the minimum control amount necessary to maintain the system voltage and dynamic reactive power reserve at their pre-specified levels to improve the power system acceptability of renewable energy. To demonstrate the effectiveness of the method proposed, a simulation has been performed for an IEEE-25 bus system. The results from simulations prove that the voltage has been well maintained while securing a dynamic reactive power reserve through optimal control based on the sensitivity analysis.",
keywords = "On-load tap-changers, Reactive power reserve, Sensitivity analysis, Sustainable energy penetration",
author = "Moonsung Bae and Hwanik Lee and Lee, {Byong Jun}",
year = "2017",
month = "8",
day = "30",
doi = "10.3390/su9091536",
language = "English",
volume = "9",
journal = "Sustainability",
issn = "2071-1050",
publisher = "MDPI AG",
number = "9",

}

TY - JOUR

T1 - An approach to improve the penetration of sustainable energy using optimal transformer tap control

AU - Bae, Moonsung

AU - Lee, Hwanik

AU - Lee, Byong Jun

PY - 2017/8/30

Y1 - 2017/8/30

N2 - A method to secure the generator reactive power reserve by adjusting the transformer tap to improve the power system penetration of renewable energy has been proposed in this study. The tap is adjusted based on the voltage and reactive power sensitivity in the power system network. That is, the transformer tap sensitivity is calculated and analyzed to adjust the tap variation to gain sufficient or the least necessary amount of reactive power reserve. This method can be effective for generators without any margins in the reserves. The optimization problem based on the calculated sensitivities and effectiveness are presented. The optimum solution derived from such a problem provides the minimum control amount necessary to maintain the system voltage and dynamic reactive power reserve at their pre-specified levels to improve the power system acceptability of renewable energy. To demonstrate the effectiveness of the method proposed, a simulation has been performed for an IEEE-25 bus system. The results from simulations prove that the voltage has been well maintained while securing a dynamic reactive power reserve through optimal control based on the sensitivity analysis.

AB - A method to secure the generator reactive power reserve by adjusting the transformer tap to improve the power system penetration of renewable energy has been proposed in this study. The tap is adjusted based on the voltage and reactive power sensitivity in the power system network. That is, the transformer tap sensitivity is calculated and analyzed to adjust the tap variation to gain sufficient or the least necessary amount of reactive power reserve. This method can be effective for generators without any margins in the reserves. The optimization problem based on the calculated sensitivities and effectiveness are presented. The optimum solution derived from such a problem provides the minimum control amount necessary to maintain the system voltage and dynamic reactive power reserve at their pre-specified levels to improve the power system acceptability of renewable energy. To demonstrate the effectiveness of the method proposed, a simulation has been performed for an IEEE-25 bus system. The results from simulations prove that the voltage has been well maintained while securing a dynamic reactive power reserve through optimal control based on the sensitivity analysis.

KW - On-load tap-changers

KW - Reactive power reserve

KW - Sensitivity analysis

KW - Sustainable energy penetration

UR - http://www.scopus.com/inward/record.url?scp=85028697172&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85028697172&partnerID=8YFLogxK

U2 - 10.3390/su9091536

DO - 10.3390/su9091536

M3 - Article

AN - SCOPUS:85028697172

VL - 9

JO - Sustainability

JF - Sustainability

SN - 2071-1050

IS - 9

M1 - 1536

ER -