TY - JOUR
T1 - Anatomically precontoured locked plates in pilon fractures
T2 - A computed tomography based and cadaveric study
AU - Sohn, Hoon Sang
AU - Oh, Jong Keon
AU - Yang, Ha
AU - Kim, Hyeong
N1 - Publisher Copyright:
© 2018 Medknow Publications. All rights reserved.
Copyright:
Copyright 2018 Elsevier B.V., All rights reserved.
PY - 2018/11/1
Y1 - 2018/11/1
N2 - Background: The treatment of comminuted tibia plafond fractures remains clinically challenging due to the complexity of the articular fracture pattern despite using the anatomically precontoured locked plates. This study describes the morphologic characteristics of the anterolateral fragment and to evaluate the fixability of the anterolateral fragment with the anatomically precontoured locked plate in the pilon fracture. Materials and Methods: One hundred and twenty five cases of AO 43-B and C fracture were evaluated using the computed tomography (CT) scan. The anterior-posterior distance in CT (APDc), medial-lateral distance in CT (MLDc), coronal and sagittal height, and articular surface area of the anterolateral fragment were measured in CT. Four types of anatomically precontoured locked plates were used for cadaveric measurement. Four cadaveric parameters were also evaluated; anteroposterior distance in plate (APDp), height of the screw in the medial plate, medial-lateral distance in plate (MLDp), and height of the screw in the anterolateral plate. Results: The anterolateral fragment was described with a mean surface area of 167.13 mm2 (APDc: 10.89 ± 4.64 mm, MLDc: 15.02 ± 6.56 mm, sagittal height: 14.85 ± 6.25 mm, and coronal height: 17.27 ± 6.88 mm). The cadaveric measurement showed that the juxta-articular screw of the medial distal tibia plate was placed away from the anterolateral fragment. The anterolateral distal tibia plate did not purchase the anterolateral fragment due to the higher position of the most distal-lateral screw (Synthes 18.37 ± 1.86 mm and Zimmer 17.78 ± 2.37 mm of the height of screw in the anterolateral plate). Conclusion: Anatomical distal tibial locked plates did not take purchase on the anterolateral fragment in pilon fracture in the best anatomical fit. Preoperative CT measurement can be used for determining a fixation strategy for the anterolateral fragment. In addition, a newly designed anterolateral distal tibia plate can be another solution when the usual anatomically precontoured distal tibia locked plate fails to cover the anterolateral fragment.
AB - Background: The treatment of comminuted tibia plafond fractures remains clinically challenging due to the complexity of the articular fracture pattern despite using the anatomically precontoured locked plates. This study describes the morphologic characteristics of the anterolateral fragment and to evaluate the fixability of the anterolateral fragment with the anatomically precontoured locked plate in the pilon fracture. Materials and Methods: One hundred and twenty five cases of AO 43-B and C fracture were evaluated using the computed tomography (CT) scan. The anterior-posterior distance in CT (APDc), medial-lateral distance in CT (MLDc), coronal and sagittal height, and articular surface area of the anterolateral fragment were measured in CT. Four types of anatomically precontoured locked plates were used for cadaveric measurement. Four cadaveric parameters were also evaluated; anteroposterior distance in plate (APDp), height of the screw in the medial plate, medial-lateral distance in plate (MLDp), and height of the screw in the anterolateral plate. Results: The anterolateral fragment was described with a mean surface area of 167.13 mm2 (APDc: 10.89 ± 4.64 mm, MLDc: 15.02 ± 6.56 mm, sagittal height: 14.85 ± 6.25 mm, and coronal height: 17.27 ± 6.88 mm). The cadaveric measurement showed that the juxta-articular screw of the medial distal tibia plate was placed away from the anterolateral fragment. The anterolateral distal tibia plate did not purchase the anterolateral fragment due to the higher position of the most distal-lateral screw (Synthes 18.37 ± 1.86 mm and Zimmer 17.78 ± 2.37 mm of the height of screw in the anterolateral plate). Conclusion: Anatomical distal tibial locked plates did not take purchase on the anterolateral fragment in pilon fracture in the best anatomical fit. Preoperative CT measurement can be used for determining a fixation strategy for the anterolateral fragment. In addition, a newly designed anterolateral distal tibia plate can be another solution when the usual anatomically precontoured distal tibia locked plate fails to cover the anterolateral fragment.
KW - Anatomically precontoured locked plate
KW - CT scan
KW - anterolateral fragment
KW - cadaver
KW - computed tomography scanners
KW - distal tibial fracture MeSH terms: Tibial fractures
KW - pilon fracture
KW - x-ray
UR - http://www.scopus.com/inward/record.url?scp=85056154768&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85056154768&partnerID=8YFLogxK
U2 - 10.4103/ortho.IJOrtho_602_16
DO - 10.4103/ortho.IJOrtho_602_16
M3 - Article
AN - SCOPUS:85056154768
VL - 52
SP - 665
EP - 671
JO - Indian Journal of Orthopaedics
JF - Indian Journal of Orthopaedics
SN - 0019-5413
IS - 6
ER -