TY - JOUR
T1 - Applicability of cement-based grout for ground heat exchanger considering heating-cooling cycles
AU - Park, Moonseo
AU - Min, Sunhong
AU - Lim, Jeehee
AU - Choi, Jong Min
AU - Choi, Hangseok
N1 - Funding Information:
This work was supported by the Fundamental Research and Development Program of the Center of New and Renewable Energy of the Ministry of Knowledge and Economy (Grant No. 2008-N-GE08-R-01) and the National Research Foundation of Korea Grant funded by the Korean Government (Grant No. 2010-0011159).
PY - 2011/7
Y1 - 2011/7
N2 - The applicability of cement grout (or cement-based grout) has been considered as an alternative to bentonite grout commonly used to backfill closed-loop vertical ground heat exchangers. In a geothermal heat pump system, repeated heating-cooling cycles may cause adverse effects on the integrity of cement grout in the ground heat exchanger. To account for the temperature cycling effect, the strength degradation of cement grout due to temperature cycling has been examined by measuring the unconfined compression strength of cured specimens in a humidity-temperature controlling chamber with applying temperature cycles between -5°C and 50°C. There is a tendency that the unconfined compression strength decreases with an increase in the number of temperature cycles. On the other hand, an equivalent hydraulic conductivity of a pipe-embedded cement grout specimen was evaluated by carrying out a modified flexible wall permeameter test equipped with a water circulating system to control temperature inside the pipe section. The applied operating temperature range was from 5 to 35°C. After three cycles of heating-cooling circulation, the equivalent hydraulic conductivity becomes asymptotic to a constant value, which implies there is no severe detachment of the pipe from the cement grout.
AB - The applicability of cement grout (or cement-based grout) has been considered as an alternative to bentonite grout commonly used to backfill closed-loop vertical ground heat exchangers. In a geothermal heat pump system, repeated heating-cooling cycles may cause adverse effects on the integrity of cement grout in the ground heat exchanger. To account for the temperature cycling effect, the strength degradation of cement grout due to temperature cycling has been examined by measuring the unconfined compression strength of cured specimens in a humidity-temperature controlling chamber with applying temperature cycles between -5°C and 50°C. There is a tendency that the unconfined compression strength decreases with an increase in the number of temperature cycles. On the other hand, an equivalent hydraulic conductivity of a pipe-embedded cement grout specimen was evaluated by carrying out a modified flexible wall permeameter test equipped with a water circulating system to control temperature inside the pipe section. The applied operating temperature range was from 5 to 35°C. After three cycles of heating-cooling circulation, the equivalent hydraulic conductivity becomes asymptotic to a constant value, which implies there is no severe detachment of the pipe from the cement grout.
KW - bentonite grout
KW - cement grout
KW - equivalent permeability coefficient
KW - thermal conductivity
KW - workability
UR - http://www.scopus.com/inward/record.url?scp=80051579205&partnerID=8YFLogxK
U2 - 10.1007/s11431-011-4388-y
DO - 10.1007/s11431-011-4388-y
M3 - Article
AN - SCOPUS:80051579205
SN - 1674-7321
VL - 54
SP - 1661
EP - 1667
JO - Science China Technological Sciences
JF - Science China Technological Sciences
IS - 7
ER -