Abstract

In this study, we demonstrated the aptamer-based biosensor (apta-biosensor) using CNT-FET devices for label free detection of allergy diagnosis by IgE detection. In order to detect the IgE, two kinds of receptor (monoclonal IgE antibody and anti-IgE aptamer)-modified CNT-FET devices were fabricated. The binding event of the target IgE onto receptors was detected by monitoring the gating effect caused by the charges of the target proteins. Since the CNT-FET biosensors were used in buffer solution, it was crucial to use small-size receptors like aptamers than whole antibodies so that the charged target IgE could approach the CNT surface within the Debye length distance to give a large gating effect. The results show that CNT-FET biosensors using monoclonal IgE antibody had very low sensitivity (minimum detectable level ~1000 ng/mL), while those based on anti-IgE aptamer could detect 50 ng/mL. Moreover, the aptamer-modified CNT-FET herein could successfully block non-target proteins and could selectively detect the target protein in an environment similar to human serum electrolyte. Therefore, aptamer-based CNT-FET devices enable the production of label-free ultrasensitive electronic biosensors to detect clinically important biomarkers for disease diagnosis.

Original languageEnglish
Pages (from-to)4182-4187
Number of pages6
JournalJournal of Nanoscience and Nanotechnology
Volume11
Issue number5
DOIs
Publication statusPublished - 2011 May 1

Fingerprint

Carbon nanotube field effect transistors
Carbon Nanotubes
Biosensing Techniques
Field effect transistors
bioinstrumentation
Biosensors
Immunoglobulin E
field effect transistors
carbon nanotubes
IgE Receptors
antibodies
Monoclonal antibodies
Equipment and Supplies
Proteins
Monoclonal Antibodies
Labels
proteins
Allergies
Electrolytes
Biomarkers

Keywords

  • Allergy
  • Aptamer
  • Biosensor
  • Carbon nanotube
  • Field effect transistor
  • IgE

ASJC Scopus subject areas

  • Condensed Matter Physics
  • Chemistry(all)
  • Materials Science(all)
  • Bioengineering
  • Biomedical Engineering

Cite this

Apta-biosensors for nonlabeled real time detection of human IgE based on carbon nanotube field effect transistors. / Kim, Jun Pyo; Hong, Seunghun; Sim, Sang Jun.

In: Journal of Nanoscience and Nanotechnology, Vol. 11, No. 5, 01.05.2011, p. 4182-4187.

Research output: Contribution to journalArticle

@article{e96c7d70d2df48f894aec1cf709c7da7,
title = "Apta-biosensors for nonlabeled real time detection of human IgE based on carbon nanotube field effect transistors",
abstract = "In this study, we demonstrated the aptamer-based biosensor (apta-biosensor) using CNT-FET devices for label free detection of allergy diagnosis by IgE detection. In order to detect the IgE, two kinds of receptor (monoclonal IgE antibody and anti-IgE aptamer)-modified CNT-FET devices were fabricated. The binding event of the target IgE onto receptors was detected by monitoring the gating effect caused by the charges of the target proteins. Since the CNT-FET biosensors were used in buffer solution, it was crucial to use small-size receptors like aptamers than whole antibodies so that the charged target IgE could approach the CNT surface within the Debye length distance to give a large gating effect. The results show that CNT-FET biosensors using monoclonal IgE antibody had very low sensitivity (minimum detectable level ~1000 ng/mL), while those based on anti-IgE aptamer could detect 50 ng/mL. Moreover, the aptamer-modified CNT-FET herein could successfully block non-target proteins and could selectively detect the target protein in an environment similar to human serum electrolyte. Therefore, aptamer-based CNT-FET devices enable the production of label-free ultrasensitive electronic biosensors to detect clinically important biomarkers for disease diagnosis.",
keywords = "Allergy, Aptamer, Biosensor, Carbon nanotube, Field effect transistor, IgE",
author = "Kim, {Jun Pyo} and Seunghun Hong and Sim, {Sang Jun}",
year = "2011",
month = "5",
day = "1",
doi = "10.1166/jnn.2011.3692",
language = "English",
volume = "11",
pages = "4182--4187",
journal = "Journal of Nanoscience and Nanotechnology",
issn = "1533-4880",
publisher = "American Scientific Publishers",
number = "5",

}

TY - JOUR

T1 - Apta-biosensors for nonlabeled real time detection of human IgE based on carbon nanotube field effect transistors

AU - Kim, Jun Pyo

AU - Hong, Seunghun

AU - Sim, Sang Jun

PY - 2011/5/1

Y1 - 2011/5/1

N2 - In this study, we demonstrated the aptamer-based biosensor (apta-biosensor) using CNT-FET devices for label free detection of allergy diagnosis by IgE detection. In order to detect the IgE, two kinds of receptor (monoclonal IgE antibody and anti-IgE aptamer)-modified CNT-FET devices were fabricated. The binding event of the target IgE onto receptors was detected by monitoring the gating effect caused by the charges of the target proteins. Since the CNT-FET biosensors were used in buffer solution, it was crucial to use small-size receptors like aptamers than whole antibodies so that the charged target IgE could approach the CNT surface within the Debye length distance to give a large gating effect. The results show that CNT-FET biosensors using monoclonal IgE antibody had very low sensitivity (minimum detectable level ~1000 ng/mL), while those based on anti-IgE aptamer could detect 50 ng/mL. Moreover, the aptamer-modified CNT-FET herein could successfully block non-target proteins and could selectively detect the target protein in an environment similar to human serum electrolyte. Therefore, aptamer-based CNT-FET devices enable the production of label-free ultrasensitive electronic biosensors to detect clinically important biomarkers for disease diagnosis.

AB - In this study, we demonstrated the aptamer-based biosensor (apta-biosensor) using CNT-FET devices for label free detection of allergy diagnosis by IgE detection. In order to detect the IgE, two kinds of receptor (monoclonal IgE antibody and anti-IgE aptamer)-modified CNT-FET devices were fabricated. The binding event of the target IgE onto receptors was detected by monitoring the gating effect caused by the charges of the target proteins. Since the CNT-FET biosensors were used in buffer solution, it was crucial to use small-size receptors like aptamers than whole antibodies so that the charged target IgE could approach the CNT surface within the Debye length distance to give a large gating effect. The results show that CNT-FET biosensors using monoclonal IgE antibody had very low sensitivity (minimum detectable level ~1000 ng/mL), while those based on anti-IgE aptamer could detect 50 ng/mL. Moreover, the aptamer-modified CNT-FET herein could successfully block non-target proteins and could selectively detect the target protein in an environment similar to human serum electrolyte. Therefore, aptamer-based CNT-FET devices enable the production of label-free ultrasensitive electronic biosensors to detect clinically important biomarkers for disease diagnosis.

KW - Allergy

KW - Aptamer

KW - Biosensor

KW - Carbon nanotube

KW - Field effect transistor

KW - IgE

UR - http://www.scopus.com/inward/record.url?scp=80051591210&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=80051591210&partnerID=8YFLogxK

U2 - 10.1166/jnn.2011.3692

DO - 10.1166/jnn.2011.3692

M3 - Article

C2 - 21780424

AN - SCOPUS:80051591210

VL - 11

SP - 4182

EP - 4187

JO - Journal of Nanoscience and Nanotechnology

JF - Journal of Nanoscience and Nanotechnology

SN - 1533-4880

IS - 5

ER -