Automated detection of rotor faults for inverter-fed induction machines under standstill conditions

Byunghwan Kim, Kwanghwan Lee, Jinkyu Yang, Sang Bin Lee, Ernesto J. Wiedenbrug, Manoj R. Shah

Research output: Contribution to journalArticle

46 Citations (Scopus)

Abstract

It is difficult to apply conventional online motor current signature analysis techniques for diagnosis of rotor faults for closed-loop induction motor drives for many applications due to the masking effect of the feedback current controller and/or variable frequency or load operation. Relying solely on traditional offline inspection techniques during regular maintenance does not allow frequent monitoring of rotor problems and is inconvenient since it requires rotor disassembly and/or manual rotor rotation. In this paper, a new automated technique for testing voltage source inverter-fed squirrel-cage induction machines at a standstill for rotor faults is proposed. The main concept is to use the inverter to excite the machine with a pulsating field at a number of angular positions to observe the variation in the impedance pattern due to broken rotor bars, whenever the motor is stopped. An experimental study on a 7.5-hp induction motor verifies that broken bars can be detected with high sensitivity and reliability. It will be shown that the proposed method can provide automated and reliable assessment of rotor condition frequently without motor disassembly, manual rotation, or additional instrumentation. The proposed test can also provide rotor quality assessment independent of variations in motor or load operating conditions since it is a standstill test.

Original languageEnglish
Article number5621894
Pages (from-to)55-64
Number of pages10
JournalIEEE Transactions on Industry Applications
Volume47
Issue number1
DOIs
Publication statusPublished - 2011 Jan 1

Fingerprint

Rotors
Induction motors
Inspection
Feedback
Controllers
Monitoring
Testing
Electric potential

Keywords

  • AC machine
  • broken rotor bar
  • condition monitoring
  • diagnostics
  • induction motor
  • inverter
  • offline testing
  • pulsating magnetic field
  • squirrel-cage rotor

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Control and Systems Engineering
  • Industrial and Manufacturing Engineering

Cite this

Automated detection of rotor faults for inverter-fed induction machines under standstill conditions. / Kim, Byunghwan; Lee, Kwanghwan; Yang, Jinkyu; Lee, Sang Bin; Wiedenbrug, Ernesto J.; Shah, Manoj R.

In: IEEE Transactions on Industry Applications, Vol. 47, No. 1, 5621894, 01.01.2011, p. 55-64.

Research output: Contribution to journalArticle

Kim, Byunghwan ; Lee, Kwanghwan ; Yang, Jinkyu ; Lee, Sang Bin ; Wiedenbrug, Ernesto J. ; Shah, Manoj R. / Automated detection of rotor faults for inverter-fed induction machines under standstill conditions. In: IEEE Transactions on Industry Applications. 2011 ; Vol. 47, No. 1. pp. 55-64.
@article{4b40e332266247e0a4ac2ed91b2a2fce,
title = "Automated detection of rotor faults for inverter-fed induction machines under standstill conditions",
abstract = "It is difficult to apply conventional online motor current signature analysis techniques for diagnosis of rotor faults for closed-loop induction motor drives for many applications due to the masking effect of the feedback current controller and/or variable frequency or load operation. Relying solely on traditional offline inspection techniques during regular maintenance does not allow frequent monitoring of rotor problems and is inconvenient since it requires rotor disassembly and/or manual rotor rotation. In this paper, a new automated technique for testing voltage source inverter-fed squirrel-cage induction machines at a standstill for rotor faults is proposed. The main concept is to use the inverter to excite the machine with a pulsating field at a number of angular positions to observe the variation in the impedance pattern due to broken rotor bars, whenever the motor is stopped. An experimental study on a 7.5-hp induction motor verifies that broken bars can be detected with high sensitivity and reliability. It will be shown that the proposed method can provide automated and reliable assessment of rotor condition frequently without motor disassembly, manual rotation, or additional instrumentation. The proposed test can also provide rotor quality assessment independent of variations in motor or load operating conditions since it is a standstill test.",
keywords = "AC machine, broken rotor bar, condition monitoring, diagnostics, induction motor, inverter, offline testing, pulsating magnetic field, squirrel-cage rotor",
author = "Byunghwan Kim and Kwanghwan Lee and Jinkyu Yang and Lee, {Sang Bin} and Wiedenbrug, {Ernesto J.} and Shah, {Manoj R.}",
year = "2011",
month = "1",
day = "1",
doi = "10.1109/TIA.2010.2090931",
language = "English",
volume = "47",
pages = "55--64",
journal = "IEEE Transactions on Industry Applications",
issn = "0093-9994",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "1",

}

TY - JOUR

T1 - Automated detection of rotor faults for inverter-fed induction machines under standstill conditions

AU - Kim, Byunghwan

AU - Lee, Kwanghwan

AU - Yang, Jinkyu

AU - Lee, Sang Bin

AU - Wiedenbrug, Ernesto J.

AU - Shah, Manoj R.

PY - 2011/1/1

Y1 - 2011/1/1

N2 - It is difficult to apply conventional online motor current signature analysis techniques for diagnosis of rotor faults for closed-loop induction motor drives for many applications due to the masking effect of the feedback current controller and/or variable frequency or load operation. Relying solely on traditional offline inspection techniques during regular maintenance does not allow frequent monitoring of rotor problems and is inconvenient since it requires rotor disassembly and/or manual rotor rotation. In this paper, a new automated technique for testing voltage source inverter-fed squirrel-cage induction machines at a standstill for rotor faults is proposed. The main concept is to use the inverter to excite the machine with a pulsating field at a number of angular positions to observe the variation in the impedance pattern due to broken rotor bars, whenever the motor is stopped. An experimental study on a 7.5-hp induction motor verifies that broken bars can be detected with high sensitivity and reliability. It will be shown that the proposed method can provide automated and reliable assessment of rotor condition frequently without motor disassembly, manual rotation, or additional instrumentation. The proposed test can also provide rotor quality assessment independent of variations in motor or load operating conditions since it is a standstill test.

AB - It is difficult to apply conventional online motor current signature analysis techniques for diagnosis of rotor faults for closed-loop induction motor drives for many applications due to the masking effect of the feedback current controller and/or variable frequency or load operation. Relying solely on traditional offline inspection techniques during regular maintenance does not allow frequent monitoring of rotor problems and is inconvenient since it requires rotor disassembly and/or manual rotor rotation. In this paper, a new automated technique for testing voltage source inverter-fed squirrel-cage induction machines at a standstill for rotor faults is proposed. The main concept is to use the inverter to excite the machine with a pulsating field at a number of angular positions to observe the variation in the impedance pattern due to broken rotor bars, whenever the motor is stopped. An experimental study on a 7.5-hp induction motor verifies that broken bars can be detected with high sensitivity and reliability. It will be shown that the proposed method can provide automated and reliable assessment of rotor condition frequently without motor disassembly, manual rotation, or additional instrumentation. The proposed test can also provide rotor quality assessment independent of variations in motor or load operating conditions since it is a standstill test.

KW - AC machine

KW - broken rotor bar

KW - condition monitoring

KW - diagnostics

KW - induction motor

KW - inverter

KW - offline testing

KW - pulsating magnetic field

KW - squirrel-cage rotor

UR - http://www.scopus.com/inward/record.url?scp=78751676315&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=78751676315&partnerID=8YFLogxK

U2 - 10.1109/TIA.2010.2090931

DO - 10.1109/TIA.2010.2090931

M3 - Article

AN - SCOPUS:78751676315

VL - 47

SP - 55

EP - 64

JO - IEEE Transactions on Industry Applications

JF - IEEE Transactions on Industry Applications

SN - 0093-9994

IS - 1

M1 - 5621894

ER -