Back-analyses of in-situ thermal response test (TRT) for evaluating ground thermal conductivity

C. Lee, M. Park, S. Park, J. Won, Hangseok Choi

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

In this study, a series of computational fluid dynamics (CFD) numerical analyses was performed in order to evaluate the performance of six full-scale closed-loop vertical ground heat exchangers constructed in a test bed located in Wonju, South Korea. The high-density polyethylene pipe, borehole grouting and surrounding ground formation were modeled using FLUENT, a finite-volume method program, for analyzing the heat transfer process of the system. Two user-defined functions accounting for the difference in the temperatures of the circulating inflow and outflow fluid and the variation of the surrounding ground temperature with depth were adopted in the FLUENT model. The relevant thermal properties of materials measured in laboratory were used in the numerical analyses to compare the thermal efficiency of various types of the heat exchangers installed in the test bed. The numerical simulations provide verification for the in-situ thermal response test (TRT) results. The numerical analysis with the ground thermal conductivity of 4.0 W/m{dot operator}K yielded by the back-analysis was in better agreement with the in-situ TRT result than with the ground thermal conductivity of 3.0 W/m{dot operator}K. From the results of CFD back-analyses, the effective thermal conductivities estimated from both the in-situ TRT and numerical analysis are smaller than the ground thermal conductivity (=4.0 W/m{bullet operator}K) that is input in the numerical model because of the intrinsic limitation of the line source model that simplifies a borehole assemblage as an infinitely long line source in the homogeneous material. However, the discrepancy between the ground thermal conductivity and the effective thermal conductivity from the in-situ TRT decreases when borehole resistance decreases with a new three pipe-type heat exchanger leads to less thermal interference between the inlet and outlet pipes than the conventional U-loop type heat exchanger.

Original languageEnglish
Pages (from-to)1397-1404
Number of pages8
JournalInternational Journal of Energy Research
Volume37
Issue number11
DOIs
Publication statusPublished - 2013 Sep 1

Fingerprint

Thermal conductivity
Heat exchangers
Boreholes
Pipe
Numerical analysis
Computational fluid dynamics
Grouting
Finite volume method
High density polyethylenes
Hot Temperature
Mathematical operators
Numerical models
Thermodynamic properties
Heat transfer
Temperature
Fluids
Computer simulation

Keywords

  • Back-analysis
  • Closed-loop vertical ground heat exchanger
  • Computational fluid dynamics
  • Effective thermal conductivity
  • Thermal response test

ASJC Scopus subject areas

  • Energy Engineering and Power Technology
  • Fuel Technology
  • Nuclear Energy and Engineering
  • Renewable Energy, Sustainability and the Environment

Cite this

Back-analyses of in-situ thermal response test (TRT) for evaluating ground thermal conductivity. / Lee, C.; Park, M.; Park, S.; Won, J.; Choi, Hangseok.

In: International Journal of Energy Research, Vol. 37, No. 11, 01.09.2013, p. 1397-1404.

Research output: Contribution to journalArticle

@article{b57d6154122c43b988576f80b64960ff,
title = "Back-analyses of in-situ thermal response test (TRT) for evaluating ground thermal conductivity",
abstract = "In this study, a series of computational fluid dynamics (CFD) numerical analyses was performed in order to evaluate the performance of six full-scale closed-loop vertical ground heat exchangers constructed in a test bed located in Wonju, South Korea. The high-density polyethylene pipe, borehole grouting and surrounding ground formation were modeled using FLUENT, a finite-volume method program, for analyzing the heat transfer process of the system. Two user-defined functions accounting for the difference in the temperatures of the circulating inflow and outflow fluid and the variation of the surrounding ground temperature with depth were adopted in the FLUENT model. The relevant thermal properties of materials measured in laboratory were used in the numerical analyses to compare the thermal efficiency of various types of the heat exchangers installed in the test bed. The numerical simulations provide verification for the in-situ thermal response test (TRT) results. The numerical analysis with the ground thermal conductivity of 4.0 W/m{dot operator}K yielded by the back-analysis was in better agreement with the in-situ TRT result than with the ground thermal conductivity of 3.0 W/m{dot operator}K. From the results of CFD back-analyses, the effective thermal conductivities estimated from both the in-situ TRT and numerical analysis are smaller than the ground thermal conductivity (=4.0 W/m{bullet operator}K) that is input in the numerical model because of the intrinsic limitation of the line source model that simplifies a borehole assemblage as an infinitely long line source in the homogeneous material. However, the discrepancy between the ground thermal conductivity and the effective thermal conductivity from the in-situ TRT decreases when borehole resistance decreases with a new three pipe-type heat exchanger leads to less thermal interference between the inlet and outlet pipes than the conventional U-loop type heat exchanger.",
keywords = "Back-analysis, Closed-loop vertical ground heat exchanger, Computational fluid dynamics, Effective thermal conductivity, Thermal response test",
author = "C. Lee and M. Park and S. Park and J. Won and Hangseok Choi",
year = "2013",
month = "9",
day = "1",
doi = "10.1002/er.2929",
language = "English",
volume = "37",
pages = "1397--1404",
journal = "International Journal of Energy Research",
issn = "0363-907X",
publisher = "John Wiley and Sons Ltd",
number = "11",

}

TY - JOUR

T1 - Back-analyses of in-situ thermal response test (TRT) for evaluating ground thermal conductivity

AU - Lee, C.

AU - Park, M.

AU - Park, S.

AU - Won, J.

AU - Choi, Hangseok

PY - 2013/9/1

Y1 - 2013/9/1

N2 - In this study, a series of computational fluid dynamics (CFD) numerical analyses was performed in order to evaluate the performance of six full-scale closed-loop vertical ground heat exchangers constructed in a test bed located in Wonju, South Korea. The high-density polyethylene pipe, borehole grouting and surrounding ground formation were modeled using FLUENT, a finite-volume method program, for analyzing the heat transfer process of the system. Two user-defined functions accounting for the difference in the temperatures of the circulating inflow and outflow fluid and the variation of the surrounding ground temperature with depth were adopted in the FLUENT model. The relevant thermal properties of materials measured in laboratory were used in the numerical analyses to compare the thermal efficiency of various types of the heat exchangers installed in the test bed. The numerical simulations provide verification for the in-situ thermal response test (TRT) results. The numerical analysis with the ground thermal conductivity of 4.0 W/m{dot operator}K yielded by the back-analysis was in better agreement with the in-situ TRT result than with the ground thermal conductivity of 3.0 W/m{dot operator}K. From the results of CFD back-analyses, the effective thermal conductivities estimated from both the in-situ TRT and numerical analysis are smaller than the ground thermal conductivity (=4.0 W/m{bullet operator}K) that is input in the numerical model because of the intrinsic limitation of the line source model that simplifies a borehole assemblage as an infinitely long line source in the homogeneous material. However, the discrepancy between the ground thermal conductivity and the effective thermal conductivity from the in-situ TRT decreases when borehole resistance decreases with a new three pipe-type heat exchanger leads to less thermal interference between the inlet and outlet pipes than the conventional U-loop type heat exchanger.

AB - In this study, a series of computational fluid dynamics (CFD) numerical analyses was performed in order to evaluate the performance of six full-scale closed-loop vertical ground heat exchangers constructed in a test bed located in Wonju, South Korea. The high-density polyethylene pipe, borehole grouting and surrounding ground formation were modeled using FLUENT, a finite-volume method program, for analyzing the heat transfer process of the system. Two user-defined functions accounting for the difference in the temperatures of the circulating inflow and outflow fluid and the variation of the surrounding ground temperature with depth were adopted in the FLUENT model. The relevant thermal properties of materials measured in laboratory were used in the numerical analyses to compare the thermal efficiency of various types of the heat exchangers installed in the test bed. The numerical simulations provide verification for the in-situ thermal response test (TRT) results. The numerical analysis with the ground thermal conductivity of 4.0 W/m{dot operator}K yielded by the back-analysis was in better agreement with the in-situ TRT result than with the ground thermal conductivity of 3.0 W/m{dot operator}K. From the results of CFD back-analyses, the effective thermal conductivities estimated from both the in-situ TRT and numerical analysis are smaller than the ground thermal conductivity (=4.0 W/m{bullet operator}K) that is input in the numerical model because of the intrinsic limitation of the line source model that simplifies a borehole assemblage as an infinitely long line source in the homogeneous material. However, the discrepancy between the ground thermal conductivity and the effective thermal conductivity from the in-situ TRT decreases when borehole resistance decreases with a new three pipe-type heat exchanger leads to less thermal interference between the inlet and outlet pipes than the conventional U-loop type heat exchanger.

KW - Back-analysis

KW - Closed-loop vertical ground heat exchanger

KW - Computational fluid dynamics

KW - Effective thermal conductivity

KW - Thermal response test

UR - http://www.scopus.com/inward/record.url?scp=84880333726&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84880333726&partnerID=8YFLogxK

U2 - 10.1002/er.2929

DO - 10.1002/er.2929

M3 - Article

AN - SCOPUS:84880333726

VL - 37

SP - 1397

EP - 1404

JO - International Journal of Energy Research

JF - International Journal of Energy Research

SN - 0363-907X

IS - 11

ER -