TY - JOUR
T1 - Changes in the Matrix Metalloproteinase 9 Point-of-Care Test Positivity According to MMP-9 Concentration and Loading Volume
AU - Huh, Jungah
AU - Choi, Soo Youn
AU - Eom, Youngsub
AU - Kim, Hyo Myung
AU - Song, Jong Suk
N1 - Publisher Copyright:
© 2020 Lippincott Williams and Wilkins. All rights reserved.
PY - 2020/2/1
Y1 - 2020/2/1
N2 - Purpose: To measure changes in the matrix metalloproteinase 9 (MMP-9) point-of-care test, InflammaDry (Rapid Pathogen Screening, Inc, Sarasota, FL) positivity, based on ocular surface MMP-9 concentrations and loading volume. Methods: Two different MMP-9 products, preform and active, were analyzed using the InflammaDry test, detecting MMP-9 levels of more than 40 ng/mL of both preform and active MMP-9. Preform MMP-9 (Natural human MMP-9 protein; Abcam, Cambridge, UK) was analyzed at different concentrations (50, 100, 500, 1000, and 1500 ng/mL) and loading volumes (5, 10, and 20 mL). Active MMP-9 (Human MMP-9 protein; Novus Biologicals, Littleton, CO) was also analyzed using the InflammaDry test at different concentrations (50 and 100 ng/mL) and loading volumes (10, 20, and 40 mL). Results: Natural human MMP-9 protein (preform) of 50, 100, and 500 ng/mL exhibited negative results for every loading volume. At 1000 ng/mL, the 20 mL volume was positive, whereas the 5 and 10 mL volumes were negative. At 1500 ng/mL, all loading volumes were positive, but the density of positive bands varied depending on the loading volume; larger loading volumes had higher band density. Human MMP-9 protein (active) of 50 ng/mL was negative for every loading volume. In 100 ng/mL, the 20 and 40 mL volumes showed positive results with similar positive band densities. Conclusions: The InflammaDry test had a different detection range depending on MMP-9 formulas; higher concentrations of preform MMP-9 protein were needed to yield positive results. In addition, InflammaDry positivity varied based on the loading volumes. Clinicians should be aware of the possibility of false negatives with low tear volumes despite elevated MMP-9 concentrations.
AB - Purpose: To measure changes in the matrix metalloproteinase 9 (MMP-9) point-of-care test, InflammaDry (Rapid Pathogen Screening, Inc, Sarasota, FL) positivity, based on ocular surface MMP-9 concentrations and loading volume. Methods: Two different MMP-9 products, preform and active, were analyzed using the InflammaDry test, detecting MMP-9 levels of more than 40 ng/mL of both preform and active MMP-9. Preform MMP-9 (Natural human MMP-9 protein; Abcam, Cambridge, UK) was analyzed at different concentrations (50, 100, 500, 1000, and 1500 ng/mL) and loading volumes (5, 10, and 20 mL). Active MMP-9 (Human MMP-9 protein; Novus Biologicals, Littleton, CO) was also analyzed using the InflammaDry test at different concentrations (50 and 100 ng/mL) and loading volumes (10, 20, and 40 mL). Results: Natural human MMP-9 protein (preform) of 50, 100, and 500 ng/mL exhibited negative results for every loading volume. At 1000 ng/mL, the 20 mL volume was positive, whereas the 5 and 10 mL volumes were negative. At 1500 ng/mL, all loading volumes were positive, but the density of positive bands varied depending on the loading volume; larger loading volumes had higher band density. Human MMP-9 protein (active) of 50 ng/mL was negative for every loading volume. In 100 ng/mL, the 20 and 40 mL volumes showed positive results with similar positive band densities. Conclusions: The InflammaDry test had a different detection range depending on MMP-9 formulas; higher concentrations of preform MMP-9 protein were needed to yield positive results. In addition, InflammaDry positivity varied based on the loading volumes. Clinicians should be aware of the possibility of false negatives with low tear volumes despite elevated MMP-9 concentrations.
KW - InflammaDry
KW - MMP-9
KW - point-of-care test
KW - tear concentration
UR - http://www.scopus.com/inward/record.url?scp=85077402606&partnerID=8YFLogxK
U2 - 10.1097/ICO.0000000000002096
DO - 10.1097/ICO.0000000000002096
M3 - Article
C2 - 31369458
AN - SCOPUS:85077402606
VL - 39
SP - 234
JO - Cornea
JF - Cornea
SN - 0277-3740
IS - 2
ER -