Characteristics of a gas type X-ray detector based on plasma display technology

Hanho Park, Sangheum Eom, Jungwon Kang, Hakjae Lee, Kisung Lee

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

A gas type detector based on plasma display technology was investigated as a candidate for the flat-panel radiation detector. Considering the simulation results with the Garfield code, prototype detectors were fabricated. The sensitivity of Xe 100% detector was 0.20 nC/mR•cm2 at the electric field of 0.36 V/um and it is about a tenth lower compared to that of a-Se detector at 10 V/um.

Original languageEnglish
Title of host publicationProceedings of the International Display Workshops
Pages712-715
Number of pages4
Volume2
Publication statusPublished - 2012 Dec 1
Event19th International Display Workshops in Conjunction with Asia Display 2012, IDW/AD 2012 - Kyoto, Japan
Duration: 2012 Dec 42012 Dec 7

Other

Other19th International Display Workshops in Conjunction with Asia Display 2012, IDW/AD 2012
CountryJapan
CityKyoto
Period12/12/412/12/7

Fingerprint

Gases
Display devices
X-Rays
Radiation
Technology
Detectors
Plasmas
X rays
Radiation detectors
Electric fields

Keywords

  • Gas-filled detectors
  • PDP
  • Radiation detectors
  • X-ray

ASJC Scopus subject areas

  • Computer Vision and Pattern Recognition
  • Human-Computer Interaction
  • Electrical and Electronic Engineering
  • Electronic, Optical and Magnetic Materials
  • Radiology Nuclear Medicine and imaging

Cite this

Park, H., Eom, S., Kang, J., Lee, H., & Lee, K. (2012). Characteristics of a gas type X-ray detector based on plasma display technology. In Proceedings of the International Display Workshops (Vol. 2, pp. 712-715)

Characteristics of a gas type X-ray detector based on plasma display technology. / Park, Hanho; Eom, Sangheum; Kang, Jungwon; Lee, Hakjae; Lee, Kisung.

Proceedings of the International Display Workshops. Vol. 2 2012. p. 712-715.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Park, H, Eom, S, Kang, J, Lee, H & Lee, K 2012, Characteristics of a gas type X-ray detector based on plasma display technology. in Proceedings of the International Display Workshops. vol. 2, pp. 712-715, 19th International Display Workshops in Conjunction with Asia Display 2012, IDW/AD 2012, Kyoto, Japan, 12/12/4.
Park H, Eom S, Kang J, Lee H, Lee K. Characteristics of a gas type X-ray detector based on plasma display technology. In Proceedings of the International Display Workshops. Vol. 2. 2012. p. 712-715
Park, Hanho ; Eom, Sangheum ; Kang, Jungwon ; Lee, Hakjae ; Lee, Kisung. / Characteristics of a gas type X-ray detector based on plasma display technology. Proceedings of the International Display Workshops. Vol. 2 2012. pp. 712-715
@inproceedings{62b0b21b4d0148968f011fed738b6a95,
title = "Characteristics of a gas type X-ray detector based on plasma display technology",
abstract = "A gas type detector based on plasma display technology was investigated as a candidate for the flat-panel radiation detector. Considering the simulation results with the Garfield code, prototype detectors were fabricated. The sensitivity of Xe 100{\%} detector was 0.20 nC/mR•cm2 at the electric field of 0.36 V/um and it is about a tenth lower compared to that of a-Se detector at 10 V/um.",
keywords = "Gas-filled detectors, PDP, Radiation detectors, X-ray",
author = "Hanho Park and Sangheum Eom and Jungwon Kang and Hakjae Lee and Kisung Lee",
year = "2012",
month = "12",
day = "1",
language = "English",
isbn = "9781627486521",
volume = "2",
pages = "712--715",
booktitle = "Proceedings of the International Display Workshops",

}

TY - GEN

T1 - Characteristics of a gas type X-ray detector based on plasma display technology

AU - Park, Hanho

AU - Eom, Sangheum

AU - Kang, Jungwon

AU - Lee, Hakjae

AU - Lee, Kisung

PY - 2012/12/1

Y1 - 2012/12/1

N2 - A gas type detector based on plasma display technology was investigated as a candidate for the flat-panel radiation detector. Considering the simulation results with the Garfield code, prototype detectors were fabricated. The sensitivity of Xe 100% detector was 0.20 nC/mR•cm2 at the electric field of 0.36 V/um and it is about a tenth lower compared to that of a-Se detector at 10 V/um.

AB - A gas type detector based on plasma display technology was investigated as a candidate for the flat-panel radiation detector. Considering the simulation results with the Garfield code, prototype detectors were fabricated. The sensitivity of Xe 100% detector was 0.20 nC/mR•cm2 at the electric field of 0.36 V/um and it is about a tenth lower compared to that of a-Se detector at 10 V/um.

KW - Gas-filled detectors

KW - PDP

KW - Radiation detectors

KW - X-ray

UR - http://www.scopus.com/inward/record.url?scp=84885918684&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84885918684&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:84885918684

SN - 9781627486521

VL - 2

SP - 712

EP - 715

BT - Proceedings of the International Display Workshops

ER -