Comparative performance evaluation of conventional and condenser outlet split ejector-based domestic refrigerator-freezers using R600a

Yongseok Jeon, Dongwoo Kim, Jongho Jung, Dong Soo Jang, Yong Chan Kim

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

The objective of this study is to investigate the performance characteristics of an R600a domestic refrigerator-freezer (RF) adopting a condenser outlet split (COS) ejector cycle. Experiments are conducted to measure the performances of conventional and COS ejector-based domestic RFs using R600a. A test bench is used to analyze the pressure lifting effect, mass flow rate variation, and coefficient of performance (COP) improvement with respect to the entrainment ratio (ER). For entire cycle operation at similar cooling capacity condition, the overall COP improvement of the test bench adopting COS ejector cycle over the baseline cycle is 11.4% at the ER of 0.18. Moreover, the COS ejector-based domestic RF is tested to examine its feasibility in actual applications. The COS ejector-based domestic RF with a compressor speed of 1450 rpm exhibits a temperature profile in the freezer compartment that is similar to that of the baseline domestic RF. At similar cooling capacity condition, the energy consumption of the COS ejector-based domestic RF with the compressor speed of 1450 rpm is 10.9% lower than that of the baseline domestic RF, owing to the pressure lifting effect.

Original languageEnglish
Pages (from-to)1085-1095
Number of pages11
JournalEnergy
Volume161
DOIs
Publication statusPublished - 2018 Oct 15

Fingerprint

Condensers (liquefiers)
Refrigerators
Ejectors (pumps)
Compressors
Cooling
Energy utilization
Flow rate

Keywords

  • Coefficient of performance
  • Condenser outlet split
  • Domestic refrigerator-freezer
  • Ejector

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Building and Construction
  • Pollution
  • Mechanical Engineering
  • Industrial and Manufacturing Engineering
  • Electrical and Electronic Engineering

Cite this

Comparative performance evaluation of conventional and condenser outlet split ejector-based domestic refrigerator-freezers using R600a. / Jeon, Yongseok; Kim, Dongwoo; Jung, Jongho; Jang, Dong Soo; Kim, Yong Chan.

In: Energy, Vol. 161, 15.10.2018, p. 1085-1095.

Research output: Contribution to journalArticle

@article{d126a9b643534b759ca593664ecb22fe,
title = "Comparative performance evaluation of conventional and condenser outlet split ejector-based domestic refrigerator-freezers using R600a",
abstract = "The objective of this study is to investigate the performance characteristics of an R600a domestic refrigerator-freezer (RF) adopting a condenser outlet split (COS) ejector cycle. Experiments are conducted to measure the performances of conventional and COS ejector-based domestic RFs using R600a. A test bench is used to analyze the pressure lifting effect, mass flow rate variation, and coefficient of performance (COP) improvement with respect to the entrainment ratio (ER). For entire cycle operation at similar cooling capacity condition, the overall COP improvement of the test bench adopting COS ejector cycle over the baseline cycle is 11.4{\%} at the ER of 0.18. Moreover, the COS ejector-based domestic RF is tested to examine its feasibility in actual applications. The COS ejector-based domestic RF with a compressor speed of 1450 rpm exhibits a temperature profile in the freezer compartment that is similar to that of the baseline domestic RF. At similar cooling capacity condition, the energy consumption of the COS ejector-based domestic RF with the compressor speed of 1450 rpm is 10.9{\%} lower than that of the baseline domestic RF, owing to the pressure lifting effect.",
keywords = "Coefficient of performance, Condenser outlet split, Domestic refrigerator-freezer, Ejector",
author = "Yongseok Jeon and Dongwoo Kim and Jongho Jung and Jang, {Dong Soo} and Kim, {Yong Chan}",
year = "2018",
month = "10",
day = "15",
doi = "10.1016/j.energy.2018.08.007",
language = "English",
volume = "161",
pages = "1085--1095",
journal = "Energy",
issn = "0360-5442",
publisher = "Elsevier Limited",

}

TY - JOUR

T1 - Comparative performance evaluation of conventional and condenser outlet split ejector-based domestic refrigerator-freezers using R600a

AU - Jeon, Yongseok

AU - Kim, Dongwoo

AU - Jung, Jongho

AU - Jang, Dong Soo

AU - Kim, Yong Chan

PY - 2018/10/15

Y1 - 2018/10/15

N2 - The objective of this study is to investigate the performance characteristics of an R600a domestic refrigerator-freezer (RF) adopting a condenser outlet split (COS) ejector cycle. Experiments are conducted to measure the performances of conventional and COS ejector-based domestic RFs using R600a. A test bench is used to analyze the pressure lifting effect, mass flow rate variation, and coefficient of performance (COP) improvement with respect to the entrainment ratio (ER). For entire cycle operation at similar cooling capacity condition, the overall COP improvement of the test bench adopting COS ejector cycle over the baseline cycle is 11.4% at the ER of 0.18. Moreover, the COS ejector-based domestic RF is tested to examine its feasibility in actual applications. The COS ejector-based domestic RF with a compressor speed of 1450 rpm exhibits a temperature profile in the freezer compartment that is similar to that of the baseline domestic RF. At similar cooling capacity condition, the energy consumption of the COS ejector-based domestic RF with the compressor speed of 1450 rpm is 10.9% lower than that of the baseline domestic RF, owing to the pressure lifting effect.

AB - The objective of this study is to investigate the performance characteristics of an R600a domestic refrigerator-freezer (RF) adopting a condenser outlet split (COS) ejector cycle. Experiments are conducted to measure the performances of conventional and COS ejector-based domestic RFs using R600a. A test bench is used to analyze the pressure lifting effect, mass flow rate variation, and coefficient of performance (COP) improvement with respect to the entrainment ratio (ER). For entire cycle operation at similar cooling capacity condition, the overall COP improvement of the test bench adopting COS ejector cycle over the baseline cycle is 11.4% at the ER of 0.18. Moreover, the COS ejector-based domestic RF is tested to examine its feasibility in actual applications. The COS ejector-based domestic RF with a compressor speed of 1450 rpm exhibits a temperature profile in the freezer compartment that is similar to that of the baseline domestic RF. At similar cooling capacity condition, the energy consumption of the COS ejector-based domestic RF with the compressor speed of 1450 rpm is 10.9% lower than that of the baseline domestic RF, owing to the pressure lifting effect.

KW - Coefficient of performance

KW - Condenser outlet split

KW - Domestic refrigerator-freezer

KW - Ejector

UR - http://www.scopus.com/inward/record.url?scp=85053123732&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85053123732&partnerID=8YFLogxK

U2 - 10.1016/j.energy.2018.08.007

DO - 10.1016/j.energy.2018.08.007

M3 - Article

VL - 161

SP - 1085

EP - 1095

JO - Energy

JF - Energy

SN - 0360-5442

ER -