Abstract

Side-readout of scintillation light from crystal elements in PET is an alternative to conventional end-readout configurations, with the benefit of being able to provide fine depth-of-interaction (DOI) information and good energy resolution while achieving excellent timing resolution required for time-of-flight PET. In this study, the performance of discrete LYSO scintillation elements read out from the end/side with digital silicon photomultipliers (dSiPM) has been assessed. Compared to 3 × 3 × 20 mm3 LYSO crystals read out from their ends that gave a coincidence resolving time (CRT) of 162 ± 7 ps FWHM and saturated energy spectra, a side-readout configuration achieved an excellent CRT of 144 ± 2 ps FWHM after correcting for timing skews within the dSiPM and an energy resolution of 11.8 ± 0.2% without requiring energy saturation correction. On the other hand, with smaller 3 × 3 × 5 mm3 LYSO crystals that can also be tiled/stacked to provide DOI information, a timing resolution of 134 ± 6 ps was attained but produced highly saturated energy spectra.

Original languageEnglish
Title of host publication2013 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013
PublisherInstitute of Electrical and Electronics Engineers Inc.
ISBN (Print)9781479905348
DOIs
Publication statusPublished - 2013 Jan 1
Externally publishedYes
Event2013 60th IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013 - Seoul, Korea, Republic of
Duration: 2013 Oct 272013 Nov 2

Publication series

NameIEEE Nuclear Science Symposium Conference Record
ISSN (Print)1095-7863

Other

Other2013 60th IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013
CountryKorea, Republic of
CitySeoul
Period13/10/2713/11/2

Fingerprint

Silicon
scintillation counters
readout
time measurement
scintillation
energy spectra
crystals
Light
silicon
configurations
energy
interactions
saturation

Keywords

  • depth-of-interaction (DOI)
  • Digital silicon photomultipliers
  • positron emission tomography (PET)
  • time-of-flight

ASJC Scopus subject areas

  • Radiation
  • Nuclear and High Energy Physics
  • Radiology Nuclear Medicine and imaging

Cite this

Yeom, J., Vinke, R., Bieniosek, M. F., & Levin, C. S. (2013). Comparison of end/side scintillator readout with digital-SiPM for ToF PET. In 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013 [6829322] (IEEE Nuclear Science Symposium Conference Record). Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/NSSMIC.2013.6829322

Comparison of end/side scintillator readout with digital-SiPM for ToF PET. / Yeom, Jungyeol; Vinke, Ruud; Bieniosek, Matthew F.; Levin, Craig S.

2013 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013. Institute of Electrical and Electronics Engineers Inc., 2013. 6829322 (IEEE Nuclear Science Symposium Conference Record).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Yeom, J, Vinke, R, Bieniosek, MF & Levin, CS 2013, Comparison of end/side scintillator readout with digital-SiPM for ToF PET. in 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013., 6829322, IEEE Nuclear Science Symposium Conference Record, Institute of Electrical and Electronics Engineers Inc., 2013 60th IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013, Seoul, Korea, Republic of, 13/10/27. https://doi.org/10.1109/NSSMIC.2013.6829322
Yeom J, Vinke R, Bieniosek MF, Levin CS. Comparison of end/side scintillator readout with digital-SiPM for ToF PET. In 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013. Institute of Electrical and Electronics Engineers Inc. 2013. 6829322. (IEEE Nuclear Science Symposium Conference Record). https://doi.org/10.1109/NSSMIC.2013.6829322
Yeom, Jungyeol ; Vinke, Ruud ; Bieniosek, Matthew F. ; Levin, Craig S. / Comparison of end/side scintillator readout with digital-SiPM for ToF PET. 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013. Institute of Electrical and Electronics Engineers Inc., 2013. (IEEE Nuclear Science Symposium Conference Record).
@inproceedings{9f1ba9520b0d4280bfb2a3a6e06e2f9e,
title = "Comparison of end/side scintillator readout with digital-SiPM for ToF PET",
abstract = "Side-readout of scintillation light from crystal elements in PET is an alternative to conventional end-readout configurations, with the benefit of being able to provide fine depth-of-interaction (DOI) information and good energy resolution while achieving excellent timing resolution required for time-of-flight PET. In this study, the performance of discrete LYSO scintillation elements read out from the end/side with digital silicon photomultipliers (dSiPM) has been assessed. Compared to 3 × 3 × 20 mm3 LYSO crystals read out from their ends that gave a coincidence resolving time (CRT) of 162 ± 7 ps FWHM and saturated energy spectra, a side-readout configuration achieved an excellent CRT of 144 ± 2 ps FWHM after correcting for timing skews within the dSiPM and an energy resolution of 11.8 ± 0.2{\%} without requiring energy saturation correction. On the other hand, with smaller 3 × 3 × 5 mm3 LYSO crystals that can also be tiled/stacked to provide DOI information, a timing resolution of 134 ± 6 ps was attained but produced highly saturated energy spectra.",
keywords = "depth-of-interaction (DOI), Digital silicon photomultipliers, positron emission tomography (PET), time-of-flight",
author = "Jungyeol Yeom and Ruud Vinke and Bieniosek, {Matthew F.} and Levin, {Craig S.}",
year = "2013",
month = "1",
day = "1",
doi = "10.1109/NSSMIC.2013.6829322",
language = "English",
isbn = "9781479905348",
series = "IEEE Nuclear Science Symposium Conference Record",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
booktitle = "2013 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013",

}

TY - GEN

T1 - Comparison of end/side scintillator readout with digital-SiPM for ToF PET

AU - Yeom, Jungyeol

AU - Vinke, Ruud

AU - Bieniosek, Matthew F.

AU - Levin, Craig S.

PY - 2013/1/1

Y1 - 2013/1/1

N2 - Side-readout of scintillation light from crystal elements in PET is an alternative to conventional end-readout configurations, with the benefit of being able to provide fine depth-of-interaction (DOI) information and good energy resolution while achieving excellent timing resolution required for time-of-flight PET. In this study, the performance of discrete LYSO scintillation elements read out from the end/side with digital silicon photomultipliers (dSiPM) has been assessed. Compared to 3 × 3 × 20 mm3 LYSO crystals read out from their ends that gave a coincidence resolving time (CRT) of 162 ± 7 ps FWHM and saturated energy spectra, a side-readout configuration achieved an excellent CRT of 144 ± 2 ps FWHM after correcting for timing skews within the dSiPM and an energy resolution of 11.8 ± 0.2% without requiring energy saturation correction. On the other hand, with smaller 3 × 3 × 5 mm3 LYSO crystals that can also be tiled/stacked to provide DOI information, a timing resolution of 134 ± 6 ps was attained but produced highly saturated energy spectra.

AB - Side-readout of scintillation light from crystal elements in PET is an alternative to conventional end-readout configurations, with the benefit of being able to provide fine depth-of-interaction (DOI) information and good energy resolution while achieving excellent timing resolution required for time-of-flight PET. In this study, the performance of discrete LYSO scintillation elements read out from the end/side with digital silicon photomultipliers (dSiPM) has been assessed. Compared to 3 × 3 × 20 mm3 LYSO crystals read out from their ends that gave a coincidence resolving time (CRT) of 162 ± 7 ps FWHM and saturated energy spectra, a side-readout configuration achieved an excellent CRT of 144 ± 2 ps FWHM after correcting for timing skews within the dSiPM and an energy resolution of 11.8 ± 0.2% without requiring energy saturation correction. On the other hand, with smaller 3 × 3 × 5 mm3 LYSO crystals that can also be tiled/stacked to provide DOI information, a timing resolution of 134 ± 6 ps was attained but produced highly saturated energy spectra.

KW - depth-of-interaction (DOI)

KW - Digital silicon photomultipliers

KW - positron emission tomography (PET)

KW - time-of-flight

UR - http://www.scopus.com/inward/record.url?scp=84904194041&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84904194041&partnerID=8YFLogxK

U2 - 10.1109/NSSMIC.2013.6829322

DO - 10.1109/NSSMIC.2013.6829322

M3 - Conference contribution

AN - SCOPUS:84904194041

SN - 9781479905348

T3 - IEEE Nuclear Science Symposium Conference Record

BT - 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013

PB - Institute of Electrical and Electronics Engineers Inc.

ER -