Comparison of robot-assisted and conventional total knee arthroplasty: A controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment

Young Wan Moon, Chul Won Ha, Kwan Hong Do, Chang Young Kim, Jeong Hoon Han, Sang Eun Na, Choong Hee Lee, Jae Gyoon Kim, Youn Soo Park

Research output: Contribution to journalArticle

21 Citations (Scopus)

Abstract

A functional total knee replacement has to be well aligned, which implies that it should lie along the mechanical axis and in the correct axial and rotational planes. Incorrect alignment will lead to abnormal wear, early mechanical loosening, and patellofemoral problems. There has been increased interest of late in total knee arthroplasty with robotic assistance. This study was conducted to determine whether robot-assisted total knee arthroplasty is superior to the conventional surgical method with regard to the precision of implant positioning. Materials and Methods: Twenty knee replacements, comprising ten robot-assisted procedures and ten conventional operations, were performed on ten cadavers. Two experienced surgeons performed the surgeries. Both procedures on each cadaver were performed by the same surgeon. The choice of which procedure was to be performed first was randomized. Following implantation of the prosthesis, the mechanical axis deviation, femoral coronal angle, tibial coronal angle, femoral sagittal angle, tibial sagittal angle, and femoral rotational alignment were measured via 3D CT scanning. These variables were then compared with the preoperatively planned values. Results: In the knees that underwent robot-assisted surgery, the mechanical axis deviation ranged from -1.94° to 2.13° (mean: -0.21°), the femoral coronal angle from 88.08° to 90.99° (mean: 89.81°), the tibial coronal angle from 89.01° to 92.36° (mean: 90.42°), the tibial sagittal angle from 81.72° to 86.24° (mean: 83.20°), and the femoral rotational alignment from 0.02° to 1.15° (mean: 0.52°) in relation to the transepicondylar axis. In the knees that underwent conventional surgery, the mechanical axis deviation ranged from -3.19° to 3.84° (mean: -0.48°), the femoral coronal angle from 88.36° to 92.29° (mean: 90.50°), the tibial coronal angle from 88.15° to 91.51° (mean: 89.83°), the tibial sagittal angle from 80.06° to 87.34° (mean: 84.50°), and the femoral rotational alignment from 0.32° to 4.13° (mean: 2.76°) in relation to the transepicondylar axis. In the conventional knee replacement group, there were two instances of outliers outside the range of 3° varus/valgus for the mechanical axis deviation. The robot-assisted knee replacements showed significantly superior femoral rotational alignment results compared with conventional surgery (p=0.006). There was no statistically significant difference between robot-assisted and conventional total knee arthroplasty with regard to the other variables. All the measurements showed high intra-observer and inter-observer reliability. Conclusion: Robot-assisted total knee arthroplasty showed excellent precision in the sagittal and coronal planes of the 3D CT scan. In particular, the robot-assisted technique showed better accuracy in femoral rotational alignment compared to the conventional surgery, despite the fact that the surgeons who performed the operations were more experienced and familiar with the conventional method than with robot-assisted surgery. It can thus be concluded that robot-assisted total knee arthroplasty is superior to conventional total knee arthroplasty.

Original languageEnglish
Pages (from-to)86-95
Number of pages10
JournalComputer Aided Surgery
Volume17
Issue number2
DOIs
Publication statusPublished - 2012 Mar 1
Externally publishedYes

Fingerprint

Arthroplasty
Knee Replacement Arthroplasties
Thigh
Cadaver
Robots
Surgery
Knee prostheses
Knee
Prosthesis Implantation
Computerized tomography
Robotics
Wear of materials
Scanning

Keywords

  • conventional surgery
  • mechanical axis
  • robot-assisted surgery
  • Total knee arthroplasty

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Surgery
  • Medicine(all)

Cite this

Comparison of robot-assisted and conventional total knee arthroplasty : A controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment. / Moon, Young Wan; Ha, Chul Won; Do, Kwan Hong; Kim, Chang Young; Han, Jeong Hoon; Na, Sang Eun; Lee, Choong Hee; Kim, Jae Gyoon; Park, Youn Soo.

In: Computer Aided Surgery, Vol. 17, No. 2, 01.03.2012, p. 86-95.

Research output: Contribution to journalArticle

Moon, Young Wan ; Ha, Chul Won ; Do, Kwan Hong ; Kim, Chang Young ; Han, Jeong Hoon ; Na, Sang Eun ; Lee, Choong Hee ; Kim, Jae Gyoon ; Park, Youn Soo. / Comparison of robot-assisted and conventional total knee arthroplasty : A controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment. In: Computer Aided Surgery. 2012 ; Vol. 17, No. 2. pp. 86-95.
@article{683b882d604b414a835347190753f735,
title = "Comparison of robot-assisted and conventional total knee arthroplasty: A controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment",
abstract = "A functional total knee replacement has to be well aligned, which implies that it should lie along the mechanical axis and in the correct axial and rotational planes. Incorrect alignment will lead to abnormal wear, early mechanical loosening, and patellofemoral problems. There has been increased interest of late in total knee arthroplasty with robotic assistance. This study was conducted to determine whether robot-assisted total knee arthroplasty is superior to the conventional surgical method with regard to the precision of implant positioning. Materials and Methods: Twenty knee replacements, comprising ten robot-assisted procedures and ten conventional operations, were performed on ten cadavers. Two experienced surgeons performed the surgeries. Both procedures on each cadaver were performed by the same surgeon. The choice of which procedure was to be performed first was randomized. Following implantation of the prosthesis, the mechanical axis deviation, femoral coronal angle, tibial coronal angle, femoral sagittal angle, tibial sagittal angle, and femoral rotational alignment were measured via 3D CT scanning. These variables were then compared with the preoperatively planned values. Results: In the knees that underwent robot-assisted surgery, the mechanical axis deviation ranged from -1.94° to 2.13° (mean: -0.21°), the femoral coronal angle from 88.08° to 90.99° (mean: 89.81°), the tibial coronal angle from 89.01° to 92.36° (mean: 90.42°), the tibial sagittal angle from 81.72° to 86.24° (mean: 83.20°), and the femoral rotational alignment from 0.02° to 1.15° (mean: 0.52°) in relation to the transepicondylar axis. In the knees that underwent conventional surgery, the mechanical axis deviation ranged from -3.19° to 3.84° (mean: -0.48°), the femoral coronal angle from 88.36° to 92.29° (mean: 90.50°), the tibial coronal angle from 88.15° to 91.51° (mean: 89.83°), the tibial sagittal angle from 80.06° to 87.34° (mean: 84.50°), and the femoral rotational alignment from 0.32° to 4.13° (mean: 2.76°) in relation to the transepicondylar axis. In the conventional knee replacement group, there were two instances of outliers outside the range of 3° varus/valgus for the mechanical axis deviation. The robot-assisted knee replacements showed significantly superior femoral rotational alignment results compared with conventional surgery (p=0.006). There was no statistically significant difference between robot-assisted and conventional total knee arthroplasty with regard to the other variables. All the measurements showed high intra-observer and inter-observer reliability. Conclusion: Robot-assisted total knee arthroplasty showed excellent precision in the sagittal and coronal planes of the 3D CT scan. In particular, the robot-assisted technique showed better accuracy in femoral rotational alignment compared to the conventional surgery, despite the fact that the surgeons who performed the operations were more experienced and familiar with the conventional method than with robot-assisted surgery. It can thus be concluded that robot-assisted total knee arthroplasty is superior to conventional total knee arthroplasty.",
keywords = "conventional surgery, mechanical axis, robot-assisted surgery, Total knee arthroplasty",
author = "Moon, {Young Wan} and Ha, {Chul Won} and Do, {Kwan Hong} and Kim, {Chang Young} and Han, {Jeong Hoon} and Na, {Sang Eun} and Lee, {Choong Hee} and Kim, {Jae Gyoon} and Park, {Youn Soo}",
year = "2012",
month = "3",
day = "1",
doi = "10.3109/10929088.2012.654408",
language = "English",
volume = "17",
pages = "86--95",
journal = "Computer Assisted Surgery",
issn = "1092-9088",
publisher = "Taylor and Francis Ltd.",
number = "2",

}

TY - JOUR

T1 - Comparison of robot-assisted and conventional total knee arthroplasty

T2 - A controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment

AU - Moon, Young Wan

AU - Ha, Chul Won

AU - Do, Kwan Hong

AU - Kim, Chang Young

AU - Han, Jeong Hoon

AU - Na, Sang Eun

AU - Lee, Choong Hee

AU - Kim, Jae Gyoon

AU - Park, Youn Soo

PY - 2012/3/1

Y1 - 2012/3/1

N2 - A functional total knee replacement has to be well aligned, which implies that it should lie along the mechanical axis and in the correct axial and rotational planes. Incorrect alignment will lead to abnormal wear, early mechanical loosening, and patellofemoral problems. There has been increased interest of late in total knee arthroplasty with robotic assistance. This study was conducted to determine whether robot-assisted total knee arthroplasty is superior to the conventional surgical method with regard to the precision of implant positioning. Materials and Methods: Twenty knee replacements, comprising ten robot-assisted procedures and ten conventional operations, were performed on ten cadavers. Two experienced surgeons performed the surgeries. Both procedures on each cadaver were performed by the same surgeon. The choice of which procedure was to be performed first was randomized. Following implantation of the prosthesis, the mechanical axis deviation, femoral coronal angle, tibial coronal angle, femoral sagittal angle, tibial sagittal angle, and femoral rotational alignment were measured via 3D CT scanning. These variables were then compared with the preoperatively planned values. Results: In the knees that underwent robot-assisted surgery, the mechanical axis deviation ranged from -1.94° to 2.13° (mean: -0.21°), the femoral coronal angle from 88.08° to 90.99° (mean: 89.81°), the tibial coronal angle from 89.01° to 92.36° (mean: 90.42°), the tibial sagittal angle from 81.72° to 86.24° (mean: 83.20°), and the femoral rotational alignment from 0.02° to 1.15° (mean: 0.52°) in relation to the transepicondylar axis. In the knees that underwent conventional surgery, the mechanical axis deviation ranged from -3.19° to 3.84° (mean: -0.48°), the femoral coronal angle from 88.36° to 92.29° (mean: 90.50°), the tibial coronal angle from 88.15° to 91.51° (mean: 89.83°), the tibial sagittal angle from 80.06° to 87.34° (mean: 84.50°), and the femoral rotational alignment from 0.32° to 4.13° (mean: 2.76°) in relation to the transepicondylar axis. In the conventional knee replacement group, there were two instances of outliers outside the range of 3° varus/valgus for the mechanical axis deviation. The robot-assisted knee replacements showed significantly superior femoral rotational alignment results compared with conventional surgery (p=0.006). There was no statistically significant difference between robot-assisted and conventional total knee arthroplasty with regard to the other variables. All the measurements showed high intra-observer and inter-observer reliability. Conclusion: Robot-assisted total knee arthroplasty showed excellent precision in the sagittal and coronal planes of the 3D CT scan. In particular, the robot-assisted technique showed better accuracy in femoral rotational alignment compared to the conventional surgery, despite the fact that the surgeons who performed the operations were more experienced and familiar with the conventional method than with robot-assisted surgery. It can thus be concluded that robot-assisted total knee arthroplasty is superior to conventional total knee arthroplasty.

AB - A functional total knee replacement has to be well aligned, which implies that it should lie along the mechanical axis and in the correct axial and rotational planes. Incorrect alignment will lead to abnormal wear, early mechanical loosening, and patellofemoral problems. There has been increased interest of late in total knee arthroplasty with robotic assistance. This study was conducted to determine whether robot-assisted total knee arthroplasty is superior to the conventional surgical method with regard to the precision of implant positioning. Materials and Methods: Twenty knee replacements, comprising ten robot-assisted procedures and ten conventional operations, were performed on ten cadavers. Two experienced surgeons performed the surgeries. Both procedures on each cadaver were performed by the same surgeon. The choice of which procedure was to be performed first was randomized. Following implantation of the prosthesis, the mechanical axis deviation, femoral coronal angle, tibial coronal angle, femoral sagittal angle, tibial sagittal angle, and femoral rotational alignment were measured via 3D CT scanning. These variables were then compared with the preoperatively planned values. Results: In the knees that underwent robot-assisted surgery, the mechanical axis deviation ranged from -1.94° to 2.13° (mean: -0.21°), the femoral coronal angle from 88.08° to 90.99° (mean: 89.81°), the tibial coronal angle from 89.01° to 92.36° (mean: 90.42°), the tibial sagittal angle from 81.72° to 86.24° (mean: 83.20°), and the femoral rotational alignment from 0.02° to 1.15° (mean: 0.52°) in relation to the transepicondylar axis. In the knees that underwent conventional surgery, the mechanical axis deviation ranged from -3.19° to 3.84° (mean: -0.48°), the femoral coronal angle from 88.36° to 92.29° (mean: 90.50°), the tibial coronal angle from 88.15° to 91.51° (mean: 89.83°), the tibial sagittal angle from 80.06° to 87.34° (mean: 84.50°), and the femoral rotational alignment from 0.32° to 4.13° (mean: 2.76°) in relation to the transepicondylar axis. In the conventional knee replacement group, there were two instances of outliers outside the range of 3° varus/valgus for the mechanical axis deviation. The robot-assisted knee replacements showed significantly superior femoral rotational alignment results compared with conventional surgery (p=0.006). There was no statistically significant difference between robot-assisted and conventional total knee arthroplasty with regard to the other variables. All the measurements showed high intra-observer and inter-observer reliability. Conclusion: Robot-assisted total knee arthroplasty showed excellent precision in the sagittal and coronal planes of the 3D CT scan. In particular, the robot-assisted technique showed better accuracy in femoral rotational alignment compared to the conventional surgery, despite the fact that the surgeons who performed the operations were more experienced and familiar with the conventional method than with robot-assisted surgery. It can thus be concluded that robot-assisted total knee arthroplasty is superior to conventional total knee arthroplasty.

KW - conventional surgery

KW - mechanical axis

KW - robot-assisted surgery

KW - Total knee arthroplasty

UR - http://www.scopus.com/inward/record.url?scp=84857282759&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84857282759&partnerID=8YFLogxK

U2 - 10.3109/10929088.2012.654408

DO - 10.3109/10929088.2012.654408

M3 - Article

C2 - 22348661

AN - SCOPUS:84857282759

VL - 17

SP - 86

EP - 95

JO - Computer Assisted Surgery

JF - Computer Assisted Surgery

SN - 1092-9088

IS - 2

ER -