TY - JOUR
T1 - Comparison of SRK/T and Haigis formulas for predicting corneal astigmatism correction with toric intraocular lenses
AU - Eom, Youngsub
AU - Song, Jong-Suk
AU - Kim, Yong Yeon
AU - Kim, Hyo Myung
PY - 2015/1/1
Y1 - 2015/1/1
N2 - Purpose To compare the accuracy of the SRK/T and Haigis formulas for predicting corneal astigmatism correction with a toric intraocular lens (IOL). Setting Department of Ophthalmology, Korea University College of Medicine, Seoul, South Korea. Design Retrospective cross-sectional study. Methods Eyes with an Acrysof toric IOL were enrolled in the study. The corneal plane effective cylinder power of toric IOLs (target induced astigmatism vector [TIA]) predicted by the SRK/T and Haigis formulas were compared with the cylindrical correction achieved postoperatively (surgically induced astigmatism vector [SIA]). The magnitude of error was defined as the difference between the magnitudes of the SIA and TIA. The median absolute magnitudes of error predicted by the SRK/T and Haigis formulas were compared. The median absolute errors predicted by the 2 formulas were also compared. Results The mean postoperative SIA was 1.80 diopters (D) ± 0.55 (SD). The magnitude of error predicted by the SRK/T and Haigis formulas was 0.31 ± 0.40 D and 0.23 ± 0.40 D, respectively. The median absolute magnitude of error predicted by the Haigis formula was statistically significantly smaller than that predicted by the SRK/T formula (P <.001). The median absolute error predicted by the Haigis formula (0.35 D) was also statistically significantly smaller than that predicted by the SRK/T formula (0.43 D) (P =.003). Conclusion The Haigis formula was more accurate than the SRK/T formula not only in predicting the refractive outcome but also in predicting corneal astigmatism correction by toric IOLs. Financial Disclosure No author has a financial or proprietary interest in any material or method mentioned.
AB - Purpose To compare the accuracy of the SRK/T and Haigis formulas for predicting corneal astigmatism correction with a toric intraocular lens (IOL). Setting Department of Ophthalmology, Korea University College of Medicine, Seoul, South Korea. Design Retrospective cross-sectional study. Methods Eyes with an Acrysof toric IOL were enrolled in the study. The corneal plane effective cylinder power of toric IOLs (target induced astigmatism vector [TIA]) predicted by the SRK/T and Haigis formulas were compared with the cylindrical correction achieved postoperatively (surgically induced astigmatism vector [SIA]). The magnitude of error was defined as the difference between the magnitudes of the SIA and TIA. The median absolute magnitudes of error predicted by the SRK/T and Haigis formulas were compared. The median absolute errors predicted by the 2 formulas were also compared. Results The mean postoperative SIA was 1.80 diopters (D) ± 0.55 (SD). The magnitude of error predicted by the SRK/T and Haigis formulas was 0.31 ± 0.40 D and 0.23 ± 0.40 D, respectively. The median absolute magnitude of error predicted by the Haigis formula was statistically significantly smaller than that predicted by the SRK/T formula (P <.001). The median absolute error predicted by the Haigis formula (0.35 D) was also statistically significantly smaller than that predicted by the SRK/T formula (0.43 D) (P =.003). Conclusion The Haigis formula was more accurate than the SRK/T formula not only in predicting the refractive outcome but also in predicting corneal astigmatism correction by toric IOLs. Financial Disclosure No author has a financial or proprietary interest in any material or method mentioned.
UR - http://www.scopus.com/inward/record.url?scp=84942869823&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84942869823&partnerID=8YFLogxK
U2 - 10.1016/j.jcrs.2014.12.053
DO - 10.1016/j.jcrs.2014.12.053
M3 - Article
C2 - 26432122
AN - SCOPUS:84942869823
VL - 41
SP - 1650
EP - 1657
JO - Journal of Cataract and Refractive Surgery
JF - Journal of Cataract and Refractive Surgery
SN - 0886-3350
IS - 8
ER -