Continuous monitoring of the recurrent laryngeal nerve in thyroid surgery: A critical appraisal

Gianlorenzo Dionigi, Gianluca Donatini, Luigi Boni, Stefano Rausei, Francesca Rovera, Maria Laura Tanda, Hoon Yub Kim, Feng Yu Chiang, Che Wei Wu, Alberto Mangano, Francesco Rulli, Piero F. Alesina, Renzo Dionigi

Research output: Contribution to journalReview article

25 Citations (Scopus)

Abstract

Background and Purpose: Intraoperative neuromonitoring (IONM) contributes in several ways to recurrent laryngeal nerve (RLN) protection. Notwithstanding these advantages, surgeons must be aware that the current, intermittent, mode of IONM (I-IONM) has relevant limitations. To overcome these I-IONM limitations, a continuous IONM (C-IONM) technology has been proposed. Methods: A PubMed indexed literature review of the current limitations of I-IONM is presented and a commentary about C-IONM is provided presenting the preliminary results of research on this topic. Main findings: I-IONM, despite the advantages it produces, presents some important limitations; to overcome these drawbacks a C-IONM technology has been introduced. Conclusions: RLN traction injury is still the most common cause of RLN injury and is difficult to avoid with the application of I-IONM in thyroid surgery. C-IONM is useful to prevent the imminent traction injury by detecting progressive decreases in electromyographic amplitude combined with progressive latency increases. C-IONM seems to be a technological improvement. Likely, C-IONM by vagal nerve stimulation should enhance the standardization process, RLN intraoperative information, documentation, protection, training, and research in modern thyroid surgery. Although C-IONM is a promising technology at the cutting edge of research in thyroid surgery, we need more studies to assess in an evidence-based way all its advantages.

Original languageEnglish
JournalInternational Journal of Surgery
Volume11
Issue numberS1
DOIs
Publication statusPublished - 2013 Dec 1

Fingerprint

Recurrent Laryngeal Nerve
Recurrent Laryngeal Nerve Injuries
Thyroid Gland
Traction
Technology
Research
Vagus Nerve Stimulation
Computer Security
PubMed
Documentation
Wounds and Injuries

Keywords

  • C-IONM
  • Continuous intraoperative neuromonitoring
  • IONM
  • Thyroid surgery

ASJC Scopus subject areas

  • Surgery

Cite this

Continuous monitoring of the recurrent laryngeal nerve in thyroid surgery : A critical appraisal. / Dionigi, Gianlorenzo; Donatini, Gianluca; Boni, Luigi; Rausei, Stefano; Rovera, Francesca; Tanda, Maria Laura; Kim, Hoon Yub; Chiang, Feng Yu; Wu, Che Wei; Mangano, Alberto; Rulli, Francesco; Alesina, Piero F.; Dionigi, Renzo.

In: International Journal of Surgery, Vol. 11, No. S1, 01.12.2013.

Research output: Contribution to journalReview article

Dionigi, G, Donatini, G, Boni, L, Rausei, S, Rovera, F, Tanda, ML, Kim, HY, Chiang, FY, Wu, CW, Mangano, A, Rulli, F, Alesina, PF & Dionigi, R 2013, 'Continuous monitoring of the recurrent laryngeal nerve in thyroid surgery: A critical appraisal', International Journal of Surgery, vol. 11, no. S1. https://doi.org/10.1016/S1743-9191(13)60014-X
Dionigi, Gianlorenzo ; Donatini, Gianluca ; Boni, Luigi ; Rausei, Stefano ; Rovera, Francesca ; Tanda, Maria Laura ; Kim, Hoon Yub ; Chiang, Feng Yu ; Wu, Che Wei ; Mangano, Alberto ; Rulli, Francesco ; Alesina, Piero F. ; Dionigi, Renzo. / Continuous monitoring of the recurrent laryngeal nerve in thyroid surgery : A critical appraisal. In: International Journal of Surgery. 2013 ; Vol. 11, No. S1.
@article{d2ce99bf10364ee4a0201e2aaad04033,
title = "Continuous monitoring of the recurrent laryngeal nerve in thyroid surgery: A critical appraisal",
abstract = "Background and Purpose: Intraoperative neuromonitoring (IONM) contributes in several ways to recurrent laryngeal nerve (RLN) protection. Notwithstanding these advantages, surgeons must be aware that the current, intermittent, mode of IONM (I-IONM) has relevant limitations. To overcome these I-IONM limitations, a continuous IONM (C-IONM) technology has been proposed. Methods: A PubMed indexed literature review of the current limitations of I-IONM is presented and a commentary about C-IONM is provided presenting the preliminary results of research on this topic. Main findings: I-IONM, despite the advantages it produces, presents some important limitations; to overcome these drawbacks a C-IONM technology has been introduced. Conclusions: RLN traction injury is still the most common cause of RLN injury and is difficult to avoid with the application of I-IONM in thyroid surgery. C-IONM is useful to prevent the imminent traction injury by detecting progressive decreases in electromyographic amplitude combined with progressive latency increases. C-IONM seems to be a technological improvement. Likely, C-IONM by vagal nerve stimulation should enhance the standardization process, RLN intraoperative information, documentation, protection, training, and research in modern thyroid surgery. Although C-IONM is a promising technology at the cutting edge of research in thyroid surgery, we need more studies to assess in an evidence-based way all its advantages.",
keywords = "C-IONM, Continuous intraoperative neuromonitoring, IONM, Thyroid surgery",
author = "Gianlorenzo Dionigi and Gianluca Donatini and Luigi Boni and Stefano Rausei and Francesca Rovera and Tanda, {Maria Laura} and Kim, {Hoon Yub} and Chiang, {Feng Yu} and Wu, {Che Wei} and Alberto Mangano and Francesco Rulli and Alesina, {Piero F.} and Renzo Dionigi",
year = "2013",
month = "12",
day = "1",
doi = "10.1016/S1743-9191(13)60014-X",
language = "English",
volume = "11",
journal = "International Journal of Surgery",
issn = "1743-9191",
publisher = "Elsevier BV",
number = "S1",

}

TY - JOUR

T1 - Continuous monitoring of the recurrent laryngeal nerve in thyroid surgery

T2 - A critical appraisal

AU - Dionigi, Gianlorenzo

AU - Donatini, Gianluca

AU - Boni, Luigi

AU - Rausei, Stefano

AU - Rovera, Francesca

AU - Tanda, Maria Laura

AU - Kim, Hoon Yub

AU - Chiang, Feng Yu

AU - Wu, Che Wei

AU - Mangano, Alberto

AU - Rulli, Francesco

AU - Alesina, Piero F.

AU - Dionigi, Renzo

PY - 2013/12/1

Y1 - 2013/12/1

N2 - Background and Purpose: Intraoperative neuromonitoring (IONM) contributes in several ways to recurrent laryngeal nerve (RLN) protection. Notwithstanding these advantages, surgeons must be aware that the current, intermittent, mode of IONM (I-IONM) has relevant limitations. To overcome these I-IONM limitations, a continuous IONM (C-IONM) technology has been proposed. Methods: A PubMed indexed literature review of the current limitations of I-IONM is presented and a commentary about C-IONM is provided presenting the preliminary results of research on this topic. Main findings: I-IONM, despite the advantages it produces, presents some important limitations; to overcome these drawbacks a C-IONM technology has been introduced. Conclusions: RLN traction injury is still the most common cause of RLN injury and is difficult to avoid with the application of I-IONM in thyroid surgery. C-IONM is useful to prevent the imminent traction injury by detecting progressive decreases in electromyographic amplitude combined with progressive latency increases. C-IONM seems to be a technological improvement. Likely, C-IONM by vagal nerve stimulation should enhance the standardization process, RLN intraoperative information, documentation, protection, training, and research in modern thyroid surgery. Although C-IONM is a promising technology at the cutting edge of research in thyroid surgery, we need more studies to assess in an evidence-based way all its advantages.

AB - Background and Purpose: Intraoperative neuromonitoring (IONM) contributes in several ways to recurrent laryngeal nerve (RLN) protection. Notwithstanding these advantages, surgeons must be aware that the current, intermittent, mode of IONM (I-IONM) has relevant limitations. To overcome these I-IONM limitations, a continuous IONM (C-IONM) technology has been proposed. Methods: A PubMed indexed literature review of the current limitations of I-IONM is presented and a commentary about C-IONM is provided presenting the preliminary results of research on this topic. Main findings: I-IONM, despite the advantages it produces, presents some important limitations; to overcome these drawbacks a C-IONM technology has been introduced. Conclusions: RLN traction injury is still the most common cause of RLN injury and is difficult to avoid with the application of I-IONM in thyroid surgery. C-IONM is useful to prevent the imminent traction injury by detecting progressive decreases in electromyographic amplitude combined with progressive latency increases. C-IONM seems to be a technological improvement. Likely, C-IONM by vagal nerve stimulation should enhance the standardization process, RLN intraoperative information, documentation, protection, training, and research in modern thyroid surgery. Although C-IONM is a promising technology at the cutting edge of research in thyroid surgery, we need more studies to assess in an evidence-based way all its advantages.

KW - C-IONM

KW - Continuous intraoperative neuromonitoring

KW - IONM

KW - Thyroid surgery

UR - http://www.scopus.com/inward/record.url?scp=84891732598&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84891732598&partnerID=8YFLogxK

U2 - 10.1016/S1743-9191(13)60014-X

DO - 10.1016/S1743-9191(13)60014-X

M3 - Review article

C2 - 24380551

AN - SCOPUS:84891732598

VL - 11

JO - International Journal of Surgery

JF - International Journal of Surgery

SN - 1743-9191

IS - S1

ER -