Contrast-enhanced, three-dimensional, whole-brain, black-blood imaging: Application to small brain metastases

Jaeseok Park, Eung Yeop Kim

Research output: Contribution to journalArticle

34 Citations (Scopus)

Abstract

Contrast-enhanced three-dimensional T 1-weighted imaging based on magnetization-prepared rapid-gradient recalled echo is widely used for detecting small brain metastases. However, since contrast materials remain in both blood and the tumor parenchyma and thus increase the signal intensity of both regions, it is often challenging to distinguish brain tumors from blood. In this work, we develop a T 1-weighted, black-blood version of single-slab three-dimensional turbo/fast spin echo whole-brain imaging, in which the signal intensity of the brain tumor is selectively enhanced while that of blood is suppressed. For blood suppression, variable refocusing flip angles with flow-sensitizing gradients are employed. To avoid a signal loss resulting from the flow-sensitizing scheme, the first refocusing flip angle is forced to 180°. Composite restore pulses at the end of refocusing pulse train are applied to achieve partial inversion recovery for the T 1-weighted contrast. Simulations and in vivo volunteer and patient experiments are performed, demonstrating that this approach is highly efficient in detecting small brain metastases.

Original languageEnglish
Pages (from-to)553-561
Number of pages9
JournalMagnetic Resonance in Medicine
Volume63
Issue number3
DOIs
Publication statusPublished - 2010 Mar 1
Externally publishedYes

Fingerprint

Neoplasm Metastasis
Brain
Brain Neoplasms
Neuroimaging
Contrast Media
Volunteers
Neoplasms

Keywords

  • Black blood
  • Contrast-enhanced
  • Magnetic resonance imaging
  • Metastatic tumor
  • MRI
  • Three dimensional
  • Variable flip angle

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Contrast-enhanced, three-dimensional, whole-brain, black-blood imaging : Application to small brain metastases. / Park, Jaeseok; Kim, Eung Yeop.

In: Magnetic Resonance in Medicine, Vol. 63, No. 3, 01.03.2010, p. 553-561.

Research output: Contribution to journalArticle

@article{6828df0c4c764e84a540fc54ce280a76,
title = "Contrast-enhanced, three-dimensional, whole-brain, black-blood imaging: Application to small brain metastases",
abstract = "Contrast-enhanced three-dimensional T 1-weighted imaging based on magnetization-prepared rapid-gradient recalled echo is widely used for detecting small brain metastases. However, since contrast materials remain in both blood and the tumor parenchyma and thus increase the signal intensity of both regions, it is often challenging to distinguish brain tumors from blood. In this work, we develop a T 1-weighted, black-blood version of single-slab three-dimensional turbo/fast spin echo whole-brain imaging, in which the signal intensity of the brain tumor is selectively enhanced while that of blood is suppressed. For blood suppression, variable refocusing flip angles with flow-sensitizing gradients are employed. To avoid a signal loss resulting from the flow-sensitizing scheme, the first refocusing flip angle is forced to 180°. Composite restore pulses at the end of refocusing pulse train are applied to achieve partial inversion recovery for the T 1-weighted contrast. Simulations and in vivo volunteer and patient experiments are performed, demonstrating that this approach is highly efficient in detecting small brain metastases.",
keywords = "Black blood, Contrast-enhanced, Magnetic resonance imaging, Metastatic tumor, MRI, Three dimensional, Variable flip angle",
author = "Jaeseok Park and Kim, {Eung Yeop}",
year = "2010",
month = "3",
day = "1",
doi = "10.1002/mrm.22261",
language = "English",
volume = "63",
pages = "553--561",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "3",

}

TY - JOUR

T1 - Contrast-enhanced, three-dimensional, whole-brain, black-blood imaging

T2 - Application to small brain metastases

AU - Park, Jaeseok

AU - Kim, Eung Yeop

PY - 2010/3/1

Y1 - 2010/3/1

N2 - Contrast-enhanced three-dimensional T 1-weighted imaging based on magnetization-prepared rapid-gradient recalled echo is widely used for detecting small brain metastases. However, since contrast materials remain in both blood and the tumor parenchyma and thus increase the signal intensity of both regions, it is often challenging to distinguish brain tumors from blood. In this work, we develop a T 1-weighted, black-blood version of single-slab three-dimensional turbo/fast spin echo whole-brain imaging, in which the signal intensity of the brain tumor is selectively enhanced while that of blood is suppressed. For blood suppression, variable refocusing flip angles with flow-sensitizing gradients are employed. To avoid a signal loss resulting from the flow-sensitizing scheme, the first refocusing flip angle is forced to 180°. Composite restore pulses at the end of refocusing pulse train are applied to achieve partial inversion recovery for the T 1-weighted contrast. Simulations and in vivo volunteer and patient experiments are performed, demonstrating that this approach is highly efficient in detecting small brain metastases.

AB - Contrast-enhanced three-dimensional T 1-weighted imaging based on magnetization-prepared rapid-gradient recalled echo is widely used for detecting small brain metastases. However, since contrast materials remain in both blood and the tumor parenchyma and thus increase the signal intensity of both regions, it is often challenging to distinguish brain tumors from blood. In this work, we develop a T 1-weighted, black-blood version of single-slab three-dimensional turbo/fast spin echo whole-brain imaging, in which the signal intensity of the brain tumor is selectively enhanced while that of blood is suppressed. For blood suppression, variable refocusing flip angles with flow-sensitizing gradients are employed. To avoid a signal loss resulting from the flow-sensitizing scheme, the first refocusing flip angle is forced to 180°. Composite restore pulses at the end of refocusing pulse train are applied to achieve partial inversion recovery for the T 1-weighted contrast. Simulations and in vivo volunteer and patient experiments are performed, demonstrating that this approach is highly efficient in detecting small brain metastases.

KW - Black blood

KW - Contrast-enhanced

KW - Magnetic resonance imaging

KW - Metastatic tumor

KW - MRI

KW - Three dimensional

KW - Variable flip angle

UR - http://www.scopus.com/inward/record.url?scp=77649084063&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77649084063&partnerID=8YFLogxK

U2 - 10.1002/mrm.22261

DO - 10.1002/mrm.22261

M3 - Article

C2 - 20187162

AN - SCOPUS:77649084063

VL - 63

SP - 553

EP - 561

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 3

ER -