Abstract

Control strategies as countermeasures against voltage collapse considering undesired relay operations are mainly discussed here. In the experiences of blackouts, undesired relay operations have played a very important role in cascading events leading to a voltage collapse. An algorithm for quick identification of critical relays is first depicted, the operations of which may significantly deteriorate the systems in terms of voltage stability. Then, the proposed approach determines a control strategy satisfying a relay margin criterion. For this purpose, a combinatorial optimisation formulation with a utility function evaluated by a quasi-steady-state simulation is used, and a local search algorithm to deal with binary control variables in the formulation is employed. The methodology is demonstrated with the modified New England 39-bus system.

Original languageEnglish
Pages (from-to)164-172
Number of pages9
JournalIET Generation, Transmission and Distribution
Volume3
Issue number2
DOIs
Publication statusPublished - 2009 Feb 26

Fingerprint

Electric potential
Combinatorial optimization
Voltage control

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Energy Engineering and Power Technology
  • Control and Systems Engineering

Cite this

Control strategies against voltage collapse considering undesired relay operations. / Song, H.; Lee, Byong Jun; Ajjarapu, V.

In: IET Generation, Transmission and Distribution, Vol. 3, No. 2, 26.02.2009, p. 164-172.

Research output: Contribution to journalArticle

@article{4cdc40b912bd4847b09b4f8d20ee4cf5,
title = "Control strategies against voltage collapse considering undesired relay operations",
abstract = "Control strategies as countermeasures against voltage collapse considering undesired relay operations are mainly discussed here. In the experiences of blackouts, undesired relay operations have played a very important role in cascading events leading to a voltage collapse. An algorithm for quick identification of critical relays is first depicted, the operations of which may significantly deteriorate the systems in terms of voltage stability. Then, the proposed approach determines a control strategy satisfying a relay margin criterion. For this purpose, a combinatorial optimisation formulation with a utility function evaluated by a quasi-steady-state simulation is used, and a local search algorithm to deal with binary control variables in the formulation is employed. The methodology is demonstrated with the modified New England 39-bus system.",
author = "H. Song and Lee, {Byong Jun} and V. Ajjarapu",
year = "2009",
month = "2",
day = "26",
doi = "10.1049/iet-gtd:20080055",
language = "English",
volume = "3",
pages = "164--172",
journal = "IET Generation, Transmission and Distribution",
issn = "1751-8687",
publisher = "Institution of Engineering and Technology",
number = "2",

}

TY - JOUR

T1 - Control strategies against voltage collapse considering undesired relay operations

AU - Song, H.

AU - Lee, Byong Jun

AU - Ajjarapu, V.

PY - 2009/2/26

Y1 - 2009/2/26

N2 - Control strategies as countermeasures against voltage collapse considering undesired relay operations are mainly discussed here. In the experiences of blackouts, undesired relay operations have played a very important role in cascading events leading to a voltage collapse. An algorithm for quick identification of critical relays is first depicted, the operations of which may significantly deteriorate the systems in terms of voltage stability. Then, the proposed approach determines a control strategy satisfying a relay margin criterion. For this purpose, a combinatorial optimisation formulation with a utility function evaluated by a quasi-steady-state simulation is used, and a local search algorithm to deal with binary control variables in the formulation is employed. The methodology is demonstrated with the modified New England 39-bus system.

AB - Control strategies as countermeasures against voltage collapse considering undesired relay operations are mainly discussed here. In the experiences of blackouts, undesired relay operations have played a very important role in cascading events leading to a voltage collapse. An algorithm for quick identification of critical relays is first depicted, the operations of which may significantly deteriorate the systems in terms of voltage stability. Then, the proposed approach determines a control strategy satisfying a relay margin criterion. For this purpose, a combinatorial optimisation formulation with a utility function evaluated by a quasi-steady-state simulation is used, and a local search algorithm to deal with binary control variables in the formulation is employed. The methodology is demonstrated with the modified New England 39-bus system.

UR - http://www.scopus.com/inward/record.url?scp=60649100867&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=60649100867&partnerID=8YFLogxK

U2 - 10.1049/iet-gtd:20080055

DO - 10.1049/iet-gtd:20080055

M3 - Article

AN - SCOPUS:60649100867

VL - 3

SP - 164

EP - 172

JO - IET Generation, Transmission and Distribution

JF - IET Generation, Transmission and Distribution

SN - 1751-8687

IS - 2

ER -