Abstract
The article by In J, et al. entitled, “Tips for troublesome sample-size calculation.” contained an error in the Equation 12. Before correction: (Formula Presented) The value for dropout rate was incorrectly printed as 0.9. The value for dropout rate should be corrected to 0.1. The authors apologize for any inconvenience this mistake may have caused.
Original language | English |
---|---|
Pages (from-to) | 268 |
Number of pages | 1 |
Journal | Korean journal of anesthesiology |
Volume | 73 |
Issue number | 3 |
DOIs |
|
Publication status | Published - 2020 Jun |
ASJC Scopus subject areas
- Anesthesiology and Pain Medicine