Abstract

A wavelet Electrocardiogram (ECG) detector for low-power implantable cardiac pacemakers is presented in this paper. The proposed wavelet-based ECG detector consists of a wavelet decomposer with wavelet filter banks, a QRS complex detector of hypothesis testing with wavelet-demodulated ECG signals, and a noise detector with zero-crossing points. In order to achieve high detection accuracy with low power consumption, a multi-scaled product algorithm and soft-threshold algorithm are efficiently exploited in our ECG detector implementation. Our algorithmic and architectural level approaches have been implemented and fabricated in a standard 0.35 \mu{\rm m} CMOS technology. The testchip including a low-power analog-to-digital converter (ADC) shows a low detection error-rate of 0.196% and low power consumption of 19.02 \mu{\rm W} with a 3 V supply voltage.

Original languageEnglish
Article number2229463
Pages (from-to)426-436
Number of pages11
JournalIEEE Transactions on Biomedical Circuits and Systems
Volume7
Issue number4
DOIs
Publication statusPublished - 2013 Mar 11

Fingerprint

Pacemakers
Electrocardiography
Detectors
Electric power utilization
Filter banks
Error detection
Digital to analog conversion
Testing
Electric potential

Keywords

  • Implantable cardiac pacemaker
  • multi-scaled product
  • soft-threshold algorithm
  • wavelet ECG detector

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Biomedical Engineering

Cite this

Design of wavelet-based ECG detector for implantable cardiac pacemakers. / Min, Young Jae; Kim, Hoon Ki; Kang, Yu Ri; Kim, Gil Su; Park, Jongsun; Kim, Soo-Won.

In: IEEE Transactions on Biomedical Circuits and Systems, Vol. 7, No. 4, 2229463, 11.03.2013, p. 426-436.

Research output: Contribution to journalArticle

Min, Young Jae ; Kim, Hoon Ki ; Kang, Yu Ri ; Kim, Gil Su ; Park, Jongsun ; Kim, Soo-Won. / Design of wavelet-based ECG detector for implantable cardiac pacemakers. In: IEEE Transactions on Biomedical Circuits and Systems. 2013 ; Vol. 7, No. 4. pp. 426-436.
@article{b9d2d95fc34d4e85a749e452713b4413,
title = "Design of wavelet-based ECG detector for implantable cardiac pacemakers",
abstract = "A wavelet Electrocardiogram (ECG) detector for low-power implantable cardiac pacemakers is presented in this paper. The proposed wavelet-based ECG detector consists of a wavelet decomposer with wavelet filter banks, a QRS complex detector of hypothesis testing with wavelet-demodulated ECG signals, and a noise detector with zero-crossing points. In order to achieve high detection accuracy with low power consumption, a multi-scaled product algorithm and soft-threshold algorithm are efficiently exploited in our ECG detector implementation. Our algorithmic and architectural level approaches have been implemented and fabricated in a standard 0.35 \mu{\rm m} CMOS technology. The testchip including a low-power analog-to-digital converter (ADC) shows a low detection error-rate of 0.196{\%} and low power consumption of 19.02 \mu{\rm W} with a 3 V supply voltage.",
keywords = "Implantable cardiac pacemaker, multi-scaled product, soft-threshold algorithm, wavelet ECG detector",
author = "Min, {Young Jae} and Kim, {Hoon Ki} and Kang, {Yu Ri} and Kim, {Gil Su} and Jongsun Park and Soo-Won Kim",
year = "2013",
month = "3",
day = "11",
doi = "10.1109/TBCAS.2012.2229463",
language = "English",
volume = "7",
pages = "426--436",
journal = "IEEE Transactions on Biomedical Circuits and Systems",
issn = "1932-4545",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "4",

}

TY - JOUR

T1 - Design of wavelet-based ECG detector for implantable cardiac pacemakers

AU - Min, Young Jae

AU - Kim, Hoon Ki

AU - Kang, Yu Ri

AU - Kim, Gil Su

AU - Park, Jongsun

AU - Kim, Soo-Won

PY - 2013/3/11

Y1 - 2013/3/11

N2 - A wavelet Electrocardiogram (ECG) detector for low-power implantable cardiac pacemakers is presented in this paper. The proposed wavelet-based ECG detector consists of a wavelet decomposer with wavelet filter banks, a QRS complex detector of hypothesis testing with wavelet-demodulated ECG signals, and a noise detector with zero-crossing points. In order to achieve high detection accuracy with low power consumption, a multi-scaled product algorithm and soft-threshold algorithm are efficiently exploited in our ECG detector implementation. Our algorithmic and architectural level approaches have been implemented and fabricated in a standard 0.35 \mu{\rm m} CMOS technology. The testchip including a low-power analog-to-digital converter (ADC) shows a low detection error-rate of 0.196% and low power consumption of 19.02 \mu{\rm W} with a 3 V supply voltage.

AB - A wavelet Electrocardiogram (ECG) detector for low-power implantable cardiac pacemakers is presented in this paper. The proposed wavelet-based ECG detector consists of a wavelet decomposer with wavelet filter banks, a QRS complex detector of hypothesis testing with wavelet-demodulated ECG signals, and a noise detector with zero-crossing points. In order to achieve high detection accuracy with low power consumption, a multi-scaled product algorithm and soft-threshold algorithm are efficiently exploited in our ECG detector implementation. Our algorithmic and architectural level approaches have been implemented and fabricated in a standard 0.35 \mu{\rm m} CMOS technology. The testchip including a low-power analog-to-digital converter (ADC) shows a low detection error-rate of 0.196% and low power consumption of 19.02 \mu{\rm W} with a 3 V supply voltage.

KW - Implantable cardiac pacemaker

KW - multi-scaled product

KW - soft-threshold algorithm

KW - wavelet ECG detector

UR - http://www.scopus.com/inward/record.url?scp=84881067400&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84881067400&partnerID=8YFLogxK