Detailed analysis on part load ratio characteristics and cooling energy saving of chiller staging in an office building

Byeong Mo Seo, Kwang Ho Lee

Research output: Contribution to journalArticle

17 Citations (Scopus)

Abstract

Commercial buildings account for significant portions of the total building energy in Korea and thus a variety of research on the chiller operation was carried out thus far. However, most of the researches were carried out on the chiller itself, i.e., the part load ratio characteristics and the corresponding electricity energy consumption patterns were not analyzed in the existing studies. In this study, the part load ratio and the operating characteristics of vapor compression chiller were analyzed within an office building equipped with the conventional variable air volume system. In addition, the energy consumption among different chiller staging schemes was comparatively analyzed. As a result, significant portions of total operating hours, cooling load and energy consumption turned out to be in the part load ratio range of 0 through 50% and thus the energy consumption was significantly affected by the chiller COP (Coefficient of Performance) at low part load conditions, indicating that the chiller operation at the part load is an important factor in commercial buildings. In addition, utilizing sequential chiller staging scheme can save annual cooling energy usage by more than 10.3% compared to operating a single chiller. For further reduction in cooling energy, applying the sequential control chiller staging during the intermediate season and applying the uniform control chiller staging algorithm during the cooling season is considered to be the optimal control algorithm for maximum efficiency of chillers.

Original languageEnglish
Pages (from-to)309-322
Number of pages14
JournalEnergy and Buildings
Volume119
DOIs
Publication statusPublished - 2016 May 1
Externally publishedYes

Fingerprint

Office buildings
Energy conservation
Energy utilization
Cooling
Loads (forces)
Electricity
Vapors
Air

Keywords

  • Chiller staging
  • Coefficient of performance
  • Commercial building
  • EnergyPlus
  • Part load ratio

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Building and Construction
  • Mechanical Engineering
  • Electrical and Electronic Engineering

Cite this

Detailed analysis on part load ratio characteristics and cooling energy saving of chiller staging in an office building. / Seo, Byeong Mo; Lee, Kwang Ho.

In: Energy and Buildings, Vol. 119, 01.05.2016, p. 309-322.

Research output: Contribution to journalArticle

@article{b754e6ef447445b4a6ac6e2300d05a9c,
title = "Detailed analysis on part load ratio characteristics and cooling energy saving of chiller staging in an office building",
abstract = "Commercial buildings account for significant portions of the total building energy in Korea and thus a variety of research on the chiller operation was carried out thus far. However, most of the researches were carried out on the chiller itself, i.e., the part load ratio characteristics and the corresponding electricity energy consumption patterns were not analyzed in the existing studies. In this study, the part load ratio and the operating characteristics of vapor compression chiller were analyzed within an office building equipped with the conventional variable air volume system. In addition, the energy consumption among different chiller staging schemes was comparatively analyzed. As a result, significant portions of total operating hours, cooling load and energy consumption turned out to be in the part load ratio range of 0 through 50{\%} and thus the energy consumption was significantly affected by the chiller COP (Coefficient of Performance) at low part load conditions, indicating that the chiller operation at the part load is an important factor in commercial buildings. In addition, utilizing sequential chiller staging scheme can save annual cooling energy usage by more than 10.3{\%} compared to operating a single chiller. For further reduction in cooling energy, applying the sequential control chiller staging during the intermediate season and applying the uniform control chiller staging algorithm during the cooling season is considered to be the optimal control algorithm for maximum efficiency of chillers.",
keywords = "Chiller staging, Coefficient of performance, Commercial building, EnergyPlus, Part load ratio",
author = "Seo, {Byeong Mo} and Lee, {Kwang Ho}",
year = "2016",
month = "5",
day = "1",
doi = "10.1016/j.enbuild.2016.03.067",
language = "English",
volume = "119",
pages = "309--322",
journal = "Energy and Buildings",
issn = "0378-7788",
publisher = "Elsevier BV",

}

TY - JOUR

T1 - Detailed analysis on part load ratio characteristics and cooling energy saving of chiller staging in an office building

AU - Seo, Byeong Mo

AU - Lee, Kwang Ho

PY - 2016/5/1

Y1 - 2016/5/1

N2 - Commercial buildings account for significant portions of the total building energy in Korea and thus a variety of research on the chiller operation was carried out thus far. However, most of the researches were carried out on the chiller itself, i.e., the part load ratio characteristics and the corresponding electricity energy consumption patterns were not analyzed in the existing studies. In this study, the part load ratio and the operating characteristics of vapor compression chiller were analyzed within an office building equipped with the conventional variable air volume system. In addition, the energy consumption among different chiller staging schemes was comparatively analyzed. As a result, significant portions of total operating hours, cooling load and energy consumption turned out to be in the part load ratio range of 0 through 50% and thus the energy consumption was significantly affected by the chiller COP (Coefficient of Performance) at low part load conditions, indicating that the chiller operation at the part load is an important factor in commercial buildings. In addition, utilizing sequential chiller staging scheme can save annual cooling energy usage by more than 10.3% compared to operating a single chiller. For further reduction in cooling energy, applying the sequential control chiller staging during the intermediate season and applying the uniform control chiller staging algorithm during the cooling season is considered to be the optimal control algorithm for maximum efficiency of chillers.

AB - Commercial buildings account for significant portions of the total building energy in Korea and thus a variety of research on the chiller operation was carried out thus far. However, most of the researches were carried out on the chiller itself, i.e., the part load ratio characteristics and the corresponding electricity energy consumption patterns were not analyzed in the existing studies. In this study, the part load ratio and the operating characteristics of vapor compression chiller were analyzed within an office building equipped with the conventional variable air volume system. In addition, the energy consumption among different chiller staging schemes was comparatively analyzed. As a result, significant portions of total operating hours, cooling load and energy consumption turned out to be in the part load ratio range of 0 through 50% and thus the energy consumption was significantly affected by the chiller COP (Coefficient of Performance) at low part load conditions, indicating that the chiller operation at the part load is an important factor in commercial buildings. In addition, utilizing sequential chiller staging scheme can save annual cooling energy usage by more than 10.3% compared to operating a single chiller. For further reduction in cooling energy, applying the sequential control chiller staging during the intermediate season and applying the uniform control chiller staging algorithm during the cooling season is considered to be the optimal control algorithm for maximum efficiency of chillers.

KW - Chiller staging

KW - Coefficient of performance

KW - Commercial building

KW - EnergyPlus

KW - Part load ratio

UR - http://www.scopus.com/inward/record.url?scp=84962665540&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84962665540&partnerID=8YFLogxK

U2 - 10.1016/j.enbuild.2016.03.067

DO - 10.1016/j.enbuild.2016.03.067

M3 - Article

AN - SCOPUS:84962665540

VL - 119

SP - 309

EP - 322

JO - Energy and Buildings

JF - Energy and Buildings

SN - 0378-7788

ER -