Detection of Oil Release in Unsaturated Soil and Estimation of Oil Infiltration Rate Using Hydraulic Control System and Water Content Sensor

Sang Gil Lee, Bong Ju Kim, Jae Woo Choi, Soon-Jae Lee

Research output: Contribution to journalArticle

Abstract

Rapid detection of oil released from underground storage tanks and estimation of its flow rate allows for the prevention of further contamination or the limitation of the spread of contaminants. In this research, we developed a method for oil release detection by sensing volumetric water contents (VWC) in a hydraulic control system. Oil release detection tests were conducted at bench and pilot scales. In the bench-scale test, oil and water were released directly on top of the oil release detection system. In the pilot-scale test, the release detection system was installed in the soil and the oil was spilled on the soil surface. The new oil release monitoring system was capable of detecting the oil release using the VWC decrease (0.42 → 0.11 m3/m3). The infiltration of water did not affect the value of VWC. Sequential injection or mixture of oil and water also showed a decrease in VWC (0.42 → 0.12 m3/m3). The rate of VWC decrease was directly proportional (− 0.003 ml/min) to the rate of oil infiltration. A conceptual model was suggested to delineate the mechanism of oil release detection and to estimate the rate of oil infiltration. The detectability of the oil release in soil was also verified in the pilot-scale test (0.45 → 0.12 m3/m3). The rate of oil infiltration could be estimated using the slope of the measured VWC. The amount of time for oil infiltration through the soil and dispersion during the migration should be considered to analyze the VWC curve properly. These results showed that the oil release detection system can be used to monitor oil release and to determine the rate of oil infiltration by installation in the soil near an underground storage tank.

Original languageEnglish
Article number92
JournalWater, Air, and Soil Pollution
Volume230
Issue number4
DOIs
Publication statusPublished - 2019 Apr 1

Fingerprint

Infiltration
Water content
control system
Oils
infiltration
water content
Hydraulics
sensor
hydraulics
Soils
Control systems
oil
Sensors
soil
detection
rate
underground storage
storage tank
Water
monitoring system

Keywords

  • Hydraulic control system
  • Infiltration rate
  • Oil release detection
  • Underground storage tank
  • Unsaturated soil
  • Volumetric water content

ASJC Scopus subject areas

  • Environmental Engineering
  • Environmental Chemistry
  • Ecological Modelling
  • Water Science and Technology
  • Pollution

Cite this

Detection of Oil Release in Unsaturated Soil and Estimation of Oil Infiltration Rate Using Hydraulic Control System and Water Content Sensor. / Lee, Sang Gil; Kim, Bong Ju; Choi, Jae Woo; Lee, Soon-Jae.

In: Water, Air, and Soil Pollution, Vol. 230, No. 4, 92, 01.04.2019.

Research output: Contribution to journalArticle

@article{7c6acfc00d0640b9ae33fecf082d6308,
title = "Detection of Oil Release in Unsaturated Soil and Estimation of Oil Infiltration Rate Using Hydraulic Control System and Water Content Sensor",
abstract = "Rapid detection of oil released from underground storage tanks and estimation of its flow rate allows for the prevention of further contamination or the limitation of the spread of contaminants. In this research, we developed a method for oil release detection by sensing volumetric water contents (VWC) in a hydraulic control system. Oil release detection tests were conducted at bench and pilot scales. In the bench-scale test, oil and water were released directly on top of the oil release detection system. In the pilot-scale test, the release detection system was installed in the soil and the oil was spilled on the soil surface. The new oil release monitoring system was capable of detecting the oil release using the VWC decrease (0.42 → 0.11 m3/m3). The infiltration of water did not affect the value of VWC. Sequential injection or mixture of oil and water also showed a decrease in VWC (0.42 → 0.12 m3/m3). The rate of VWC decrease was directly proportional (− 0.003 ml/min) to the rate of oil infiltration. A conceptual model was suggested to delineate the mechanism of oil release detection and to estimate the rate of oil infiltration. The detectability of the oil release in soil was also verified in the pilot-scale test (0.45 → 0.12 m3/m3). The rate of oil infiltration could be estimated using the slope of the measured VWC. The amount of time for oil infiltration through the soil and dispersion during the migration should be considered to analyze the VWC curve properly. These results showed that the oil release detection system can be used to monitor oil release and to determine the rate of oil infiltration by installation in the soil near an underground storage tank.",
keywords = "Hydraulic control system, Infiltration rate, Oil release detection, Underground storage tank, Unsaturated soil, Volumetric water content",
author = "Lee, {Sang Gil} and Kim, {Bong Ju} and Choi, {Jae Woo} and Soon-Jae Lee",
year = "2019",
month = "4",
day = "1",
doi = "10.1007/s11270-019-4147-4",
language = "English",
volume = "230",
journal = "Water, Air, and Soil Pollution",
issn = "0049-6979",
publisher = "Springer Netherlands",
number = "4",

}

TY - JOUR

T1 - Detection of Oil Release in Unsaturated Soil and Estimation of Oil Infiltration Rate Using Hydraulic Control System and Water Content Sensor

AU - Lee, Sang Gil

AU - Kim, Bong Ju

AU - Choi, Jae Woo

AU - Lee, Soon-Jae

PY - 2019/4/1

Y1 - 2019/4/1

N2 - Rapid detection of oil released from underground storage tanks and estimation of its flow rate allows for the prevention of further contamination or the limitation of the spread of contaminants. In this research, we developed a method for oil release detection by sensing volumetric water contents (VWC) in a hydraulic control system. Oil release detection tests were conducted at bench and pilot scales. In the bench-scale test, oil and water were released directly on top of the oil release detection system. In the pilot-scale test, the release detection system was installed in the soil and the oil was spilled on the soil surface. The new oil release monitoring system was capable of detecting the oil release using the VWC decrease (0.42 → 0.11 m3/m3). The infiltration of water did not affect the value of VWC. Sequential injection or mixture of oil and water also showed a decrease in VWC (0.42 → 0.12 m3/m3). The rate of VWC decrease was directly proportional (− 0.003 ml/min) to the rate of oil infiltration. A conceptual model was suggested to delineate the mechanism of oil release detection and to estimate the rate of oil infiltration. The detectability of the oil release in soil was also verified in the pilot-scale test (0.45 → 0.12 m3/m3). The rate of oil infiltration could be estimated using the slope of the measured VWC. The amount of time for oil infiltration through the soil and dispersion during the migration should be considered to analyze the VWC curve properly. These results showed that the oil release detection system can be used to monitor oil release and to determine the rate of oil infiltration by installation in the soil near an underground storage tank.

AB - Rapid detection of oil released from underground storage tanks and estimation of its flow rate allows for the prevention of further contamination or the limitation of the spread of contaminants. In this research, we developed a method for oil release detection by sensing volumetric water contents (VWC) in a hydraulic control system. Oil release detection tests were conducted at bench and pilot scales. In the bench-scale test, oil and water were released directly on top of the oil release detection system. In the pilot-scale test, the release detection system was installed in the soil and the oil was spilled on the soil surface. The new oil release monitoring system was capable of detecting the oil release using the VWC decrease (0.42 → 0.11 m3/m3). The infiltration of water did not affect the value of VWC. Sequential injection or mixture of oil and water also showed a decrease in VWC (0.42 → 0.12 m3/m3). The rate of VWC decrease was directly proportional (− 0.003 ml/min) to the rate of oil infiltration. A conceptual model was suggested to delineate the mechanism of oil release detection and to estimate the rate of oil infiltration. The detectability of the oil release in soil was also verified in the pilot-scale test (0.45 → 0.12 m3/m3). The rate of oil infiltration could be estimated using the slope of the measured VWC. The amount of time for oil infiltration through the soil and dispersion during the migration should be considered to analyze the VWC curve properly. These results showed that the oil release detection system can be used to monitor oil release and to determine the rate of oil infiltration by installation in the soil near an underground storage tank.

KW - Hydraulic control system

KW - Infiltration rate

KW - Oil release detection

KW - Underground storage tank

KW - Unsaturated soil

KW - Volumetric water content

UR - http://www.scopus.com/inward/record.url?scp=85063995119&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85063995119&partnerID=8YFLogxK

U2 - 10.1007/s11270-019-4147-4

DO - 10.1007/s11270-019-4147-4

M3 - Article

AN - SCOPUS:85063995119

VL - 230

JO - Water, Air, and Soil Pollution

JF - Water, Air, and Soil Pollution

SN - 0049-6979

IS - 4

M1 - 92

ER -