Detection of stator-slot magnetic wedge failures for induction motors without disassembly

Kun Wang Lee, Jongman Hong, Doosoo Hyun, Sang Bin Lee, Ernesto J. Wiedenbrug, Mike Teska, Chaewoong Lim

Research output: Contribution to journalArticle

11 Citations (Scopus)

Abstract

The recent trend in large ac machines is to employ magnetic stator-slot wedges for improving the motor efficiency, power factor, and power density. The mechanical strength of magnetic wedges is weak compared to the epoxy glass wedges, and many cases of loose and missing wedges have recently been increasingly reported. Magnetic wedge failure deteriorates the performance and reliability of the motor, but there is no method available for testing the wedge quality other than visual inspection after rotor removal. Monitoring of the overall wedge condition without motor disassembly can help reduce the cost of maintenance and risk of degradation in performance. In this paper, a new offline standstill test method for detecting magnetic wedge problems for ac machines without motor disassembly is proposed. An experimental study on 380-V 5.5-kW and 6.6-kV 3.4-MW motors with magnetic wedges is performed to verify the effectiveness of the new test method. It is shown that the new method can provide reliable monitoring of magnetic wedge problems over time, independent of other faults or motor design.

Original languageEnglish
Article number6663678
Pages (from-to)2410-2419
Number of pages10
JournalIEEE Transactions on Industry Applications
Volume50
Issue number4
DOIs
Publication statusPublished - 2014 Jan 1

Fingerprint

Induction motors
Stators
Monitoring
Strength of materials
Rotors
Inspection
Degradation
Glass
Testing
Costs

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Control and Systems Engineering
  • Industrial and Manufacturing Engineering

Cite this

Detection of stator-slot magnetic wedge failures for induction motors without disassembly. / Lee, Kun Wang; Hong, Jongman; Hyun, Doosoo; Lee, Sang Bin; Wiedenbrug, Ernesto J.; Teska, Mike; Lim, Chaewoong.

In: IEEE Transactions on Industry Applications, Vol. 50, No. 4, 6663678, 01.01.2014, p. 2410-2419.

Research output: Contribution to journalArticle

Lee, Kun Wang ; Hong, Jongman ; Hyun, Doosoo ; Lee, Sang Bin ; Wiedenbrug, Ernesto J. ; Teska, Mike ; Lim, Chaewoong. / Detection of stator-slot magnetic wedge failures for induction motors without disassembly. In: IEEE Transactions on Industry Applications. 2014 ; Vol. 50, No. 4. pp. 2410-2419.
@article{cdc600641c0e402ebd0ee6a041eb6e07,
title = "Detection of stator-slot magnetic wedge failures for induction motors without disassembly",
abstract = "The recent trend in large ac machines is to employ magnetic stator-slot wedges for improving the motor efficiency, power factor, and power density. The mechanical strength of magnetic wedges is weak compared to the epoxy glass wedges, and many cases of loose and missing wedges have recently been increasingly reported. Magnetic wedge failure deteriorates the performance and reliability of the motor, but there is no method available for testing the wedge quality other than visual inspection after rotor removal. Monitoring of the overall wedge condition without motor disassembly can help reduce the cost of maintenance and risk of degradation in performance. In this paper, a new offline standstill test method for detecting magnetic wedge problems for ac machines without motor disassembly is proposed. An experimental study on 380-V 5.5-kW and 6.6-kV 3.4-MW motors with magnetic wedges is performed to verify the effectiveness of the new test method. It is shown that the new method can provide reliable monitoring of magnetic wedge problems over time, independent of other faults or motor design.",
keywords = "AC machines, fault diagnosis, inverters, magnetic wedges, nondestructive testing, stators",
author = "Lee, {Kun Wang} and Jongman Hong and Doosoo Hyun and Lee, {Sang Bin} and Wiedenbrug, {Ernesto J.} and Mike Teska and Chaewoong Lim",
year = "2014",
month = "1",
day = "1",
doi = "10.1109/TIA.2013.2290869",
language = "English",
volume = "50",
pages = "2410--2419",
journal = "IEEE Transactions on Industry Applications",
issn = "0093-9994",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "4",

}

TY - JOUR

T1 - Detection of stator-slot magnetic wedge failures for induction motors without disassembly

AU - Lee, Kun Wang

AU - Hong, Jongman

AU - Hyun, Doosoo

AU - Lee, Sang Bin

AU - Wiedenbrug, Ernesto J.

AU - Teska, Mike

AU - Lim, Chaewoong

PY - 2014/1/1

Y1 - 2014/1/1

N2 - The recent trend in large ac machines is to employ magnetic stator-slot wedges for improving the motor efficiency, power factor, and power density. The mechanical strength of magnetic wedges is weak compared to the epoxy glass wedges, and many cases of loose and missing wedges have recently been increasingly reported. Magnetic wedge failure deteriorates the performance and reliability of the motor, but there is no method available for testing the wedge quality other than visual inspection after rotor removal. Monitoring of the overall wedge condition without motor disassembly can help reduce the cost of maintenance and risk of degradation in performance. In this paper, a new offline standstill test method for detecting magnetic wedge problems for ac machines without motor disassembly is proposed. An experimental study on 380-V 5.5-kW and 6.6-kV 3.4-MW motors with magnetic wedges is performed to verify the effectiveness of the new test method. It is shown that the new method can provide reliable monitoring of magnetic wedge problems over time, independent of other faults or motor design.

AB - The recent trend in large ac machines is to employ magnetic stator-slot wedges for improving the motor efficiency, power factor, and power density. The mechanical strength of magnetic wedges is weak compared to the epoxy glass wedges, and many cases of loose and missing wedges have recently been increasingly reported. Magnetic wedge failure deteriorates the performance and reliability of the motor, but there is no method available for testing the wedge quality other than visual inspection after rotor removal. Monitoring of the overall wedge condition without motor disassembly can help reduce the cost of maintenance and risk of degradation in performance. In this paper, a new offline standstill test method for detecting magnetic wedge problems for ac machines without motor disassembly is proposed. An experimental study on 380-V 5.5-kW and 6.6-kV 3.4-MW motors with magnetic wedges is performed to verify the effectiveness of the new test method. It is shown that the new method can provide reliable monitoring of magnetic wedge problems over time, independent of other faults or motor design.

KW - AC machines

KW - fault diagnosis

KW - inverters

KW - magnetic wedges

KW - nondestructive testing

KW - stators

UR - http://www.scopus.com/inward/record.url?scp=84904655044&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84904655044&partnerID=8YFLogxK

U2 - 10.1109/TIA.2013.2290869

DO - 10.1109/TIA.2013.2290869

M3 - Article

AN - SCOPUS:84904655044

VL - 50

SP - 2410

EP - 2419

JO - IEEE Transactions on Industry Applications

JF - IEEE Transactions on Industry Applications

SN - 0093-9994

IS - 4

M1 - 6663678

ER -