Certified reference materials (CRMs) which can be used to analyze anions in aqueous solution were prepared. Using ion chromatography, highly concentrated CRM solutions containing seven different anions (F-, Cl-, NO2 -, NO3 -, Br-, PO4 3-, and SO4 2-, 100 mgkg-1 each) could be directly separated without making any diluted solutions. To obtain optimized separation conditions in this highly concentrated sample solution, a number of experiments including change of eluent composition and flow-rate of the eluents and injection volumes were attempted. The best results were observed when a mixture of 2.0 mM Na2CO3 and 2.5 mM NaHCO3 as an eluent was used with conditions of 0.5 mlmin-1 as flow-rate and a 5 μl sample loop. The resolution value reached to 1.5, which is sufficient for quantitative analysis and all of seven different anions were perfectly separated within 15 min. Copyright (C) 1998 Elsevier Science B.V.

Original languageEnglish
Pages (from-to)85-90
Number of pages6
JournalJournal of Chromatography A
Volume813
Issue number1
DOIs
Publication statusPublished - 1998 Jul 10
Externally publishedYes

Fingerprint

Ion chromatography
Anions
Chromatography
Ions
Flow rate
Chemical analysis
Injections
Experiments

Keywords

  • Inorganic anions

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

Determination of anions in certified reference materials by ion chromatography. / Lee, Joung Hae; Kim, Jong Seung; Min, Byung Hoon; Kim, Sun Tae; Kim, Jong Hun.

In: Journal of Chromatography A, Vol. 813, No. 1, 10.07.1998, p. 85-90.

Research output: Contribution to journalArticle

Lee, Joung Hae ; Kim, Jong Seung ; Min, Byung Hoon ; Kim, Sun Tae ; Kim, Jong Hun. / Determination of anions in certified reference materials by ion chromatography. In: Journal of Chromatography A. 1998 ; Vol. 813, No. 1. pp. 85-90.
@article{bfcb55b252ae4c0d89bc61b528cf8811,
title = "Determination of anions in certified reference materials by ion chromatography",
abstract = "Certified reference materials (CRMs) which can be used to analyze anions in aqueous solution were prepared. Using ion chromatography, highly concentrated CRM solutions containing seven different anions (F-, Cl-, NO2 -, NO3 -, Br-, PO4 3-, and SO4 2-, 100 mgkg-1 each) could be directly separated without making any diluted solutions. To obtain optimized separation conditions in this highly concentrated sample solution, a number of experiments including change of eluent composition and flow-rate of the eluents and injection volumes were attempted. The best results were observed when a mixture of 2.0 mM Na2CO3 and 2.5 mM NaHCO3 as an eluent was used with conditions of 0.5 mlmin-1 as flow-rate and a 5 μl sample loop. The resolution value reached to 1.5, which is sufficient for quantitative analysis and all of seven different anions were perfectly separated within 15 min. Copyright (C) 1998 Elsevier Science B.V.",
keywords = "Inorganic anions",
author = "Lee, {Joung Hae} and Kim, {Jong Seung} and Min, {Byung Hoon} and Kim, {Sun Tae} and Kim, {Jong Hun}",
year = "1998",
month = "7",
day = "10",
doi = "10.1016/S0021-9673(98)00267-2",
language = "English",
volume = "813",
pages = "85--90",
journal = "Journal of Chromatography",
issn = "0021-9673",
publisher = "Elsevier",
number = "1",

}

TY - JOUR

T1 - Determination of anions in certified reference materials by ion chromatography

AU - Lee, Joung Hae

AU - Kim, Jong Seung

AU - Min, Byung Hoon

AU - Kim, Sun Tae

AU - Kim, Jong Hun

PY - 1998/7/10

Y1 - 1998/7/10

N2 - Certified reference materials (CRMs) which can be used to analyze anions in aqueous solution were prepared. Using ion chromatography, highly concentrated CRM solutions containing seven different anions (F-, Cl-, NO2 -, NO3 -, Br-, PO4 3-, and SO4 2-, 100 mgkg-1 each) could be directly separated without making any diluted solutions. To obtain optimized separation conditions in this highly concentrated sample solution, a number of experiments including change of eluent composition and flow-rate of the eluents and injection volumes were attempted. The best results were observed when a mixture of 2.0 mM Na2CO3 and 2.5 mM NaHCO3 as an eluent was used with conditions of 0.5 mlmin-1 as flow-rate and a 5 μl sample loop. The resolution value reached to 1.5, which is sufficient for quantitative analysis and all of seven different anions were perfectly separated within 15 min. Copyright (C) 1998 Elsevier Science B.V.

AB - Certified reference materials (CRMs) which can be used to analyze anions in aqueous solution were prepared. Using ion chromatography, highly concentrated CRM solutions containing seven different anions (F-, Cl-, NO2 -, NO3 -, Br-, PO4 3-, and SO4 2-, 100 mgkg-1 each) could be directly separated without making any diluted solutions. To obtain optimized separation conditions in this highly concentrated sample solution, a number of experiments including change of eluent composition and flow-rate of the eluents and injection volumes were attempted. The best results were observed when a mixture of 2.0 mM Na2CO3 and 2.5 mM NaHCO3 as an eluent was used with conditions of 0.5 mlmin-1 as flow-rate and a 5 μl sample loop. The resolution value reached to 1.5, which is sufficient for quantitative analysis and all of seven different anions were perfectly separated within 15 min. Copyright (C) 1998 Elsevier Science B.V.

KW - Inorganic anions

UR - http://www.scopus.com/inward/record.url?scp=0031661387&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031661387&partnerID=8YFLogxK

U2 - 10.1016/S0021-9673(98)00267-2

DO - 10.1016/S0021-9673(98)00267-2

M3 - Article

VL - 813

SP - 85

EP - 90

JO - Journal of Chromatography

JF - Journal of Chromatography

SN - 0021-9673

IS - 1

ER -