A photometric immunosensor that can be used for on-site diagnosis has been constructed. The sensor system was assembled by partially superimposing a nitrocellulose membrane strip (the lower) containing an immobilized antigen on the surface with a glass fiber membrane strip (the upper) including two electrodes on the opposite surfaces. To amplify the signal, we introduced a liposome, containing ruthenium molecules trapped in the core, chemically coupled to an antibody specific to the analyte (e.g. Legionella antigen). In the presence of the analyte, immune complexes were formed by antigen-antibody reactions upon addition of the immuno-liposome into a sample. This mixture was then absorbed by the capillary action from the bottom of the membrane strip. The liposome particles in the complexes were carried by a medium through the antigen pad without interaction, while free immuno-liposome was trapped by immune reactions on the pad surfaces. The aqueous medium influx into the glass pad dissolved a detergent pre-located within the compartment and the liposome rupture thereby released ruthenium molecules into the solution. The molecules were oxidized on the electrode surfaces and produced an electro- chemiluminescence (ECL) in proportion to the analyte concentration. The signal generation based on ECL resulted in an exponential dose-response pattern and the analyte detection limit of 2 ng/ml was approximately 10-fold more sensitive than that obtained from a conventional system.

Original languageEnglish
Pages (from-to)289-296
Number of pages8
JournalBiosensors and Bioelectronics
Volume19
Issue number4
DOIs
Publication statusPublished - 2003 Dec 15

Fingerprint

Immunosensors
Signal generators
Ruthenium
Liposomes
Membranes
Antigens
Antigen-antibody reactions
Chemiluminescence
Luminescence
Molecules
Electrodes
Capillary Action
Antigen-Antibody Reactions
Nitrocellulose
Legionella
Collodion
Detergents
Surface Antigens
Antigen-Antibody Complex
Antibodies

Keywords

  • Electro-chemiluminescence
  • Immuno-chromatographic assay
  • Immuno-liposome
  • Point-of-care device
  • Screen-printed electrodes

ASJC Scopus subject areas

  • Biotechnology
  • Analytical Chemistry
  • Electrochemistry

Cite this

Development of a membrane strip immunosensor utilizing ruthenium as an electro-chemiluminescent signal generator. / Yoon, Chae H.; Cho, Joung Hwan; Oh, Heung I.; Min, Ja Kim; Lee, Chi W.; Choi, Jeong W.; Paek, Se Hwan.

In: Biosensors and Bioelectronics, Vol. 19, No. 4, 15.12.2003, p. 289-296.

Research output: Contribution to journalArticle

Yoon, Chae H. ; Cho, Joung Hwan ; Oh, Heung I. ; Min, Ja Kim ; Lee, Chi W. ; Choi, Jeong W. ; Paek, Se Hwan. / Development of a membrane strip immunosensor utilizing ruthenium as an electro-chemiluminescent signal generator. In: Biosensors and Bioelectronics. 2003 ; Vol. 19, No. 4. pp. 289-296.
@article{57fbf33bb3d14089aa1232dc735d98e7,
title = "Development of a membrane strip immunosensor utilizing ruthenium as an electro-chemiluminescent signal generator",
abstract = "A photometric immunosensor that can be used for on-site diagnosis has been constructed. The sensor system was assembled by partially superimposing a nitrocellulose membrane strip (the lower) containing an immobilized antigen on the surface with a glass fiber membrane strip (the upper) including two electrodes on the opposite surfaces. To amplify the signal, we introduced a liposome, containing ruthenium molecules trapped in the core, chemically coupled to an antibody specific to the analyte (e.g. Legionella antigen). In the presence of the analyte, immune complexes were formed by antigen-antibody reactions upon addition of the immuno-liposome into a sample. This mixture was then absorbed by the capillary action from the bottom of the membrane strip. The liposome particles in the complexes were carried by a medium through the antigen pad without interaction, while free immuno-liposome was trapped by immune reactions on the pad surfaces. The aqueous medium influx into the glass pad dissolved a detergent pre-located within the compartment and the liposome rupture thereby released ruthenium molecules into the solution. The molecules were oxidized on the electrode surfaces and produced an electro- chemiluminescence (ECL) in proportion to the analyte concentration. The signal generation based on ECL resulted in an exponential dose-response pattern and the analyte detection limit of 2 ng/ml was approximately 10-fold more sensitive than that obtained from a conventional system.",
keywords = "Electro-chemiluminescence, Immuno-chromatographic assay, Immuno-liposome, Point-of-care device, Screen-printed electrodes",
author = "Yoon, {Chae H.} and Cho, {Joung Hwan} and Oh, {Heung I.} and Min, {Ja Kim} and Lee, {Chi W.} and Choi, {Jeong W.} and Paek, {Se Hwan}",
year = "2003",
month = "12",
day = "15",
doi = "10.1016/S0956-5663(03)00207-0",
language = "English",
volume = "19",
pages = "289--296",
journal = "Biosensors",
issn = "0956-5663",
publisher = "Elsevier Limited",
number = "4",

}

TY - JOUR

T1 - Development of a membrane strip immunosensor utilizing ruthenium as an electro-chemiluminescent signal generator

AU - Yoon, Chae H.

AU - Cho, Joung Hwan

AU - Oh, Heung I.

AU - Min, Ja Kim

AU - Lee, Chi W.

AU - Choi, Jeong W.

AU - Paek, Se Hwan

PY - 2003/12/15

Y1 - 2003/12/15

N2 - A photometric immunosensor that can be used for on-site diagnosis has been constructed. The sensor system was assembled by partially superimposing a nitrocellulose membrane strip (the lower) containing an immobilized antigen on the surface with a glass fiber membrane strip (the upper) including two electrodes on the opposite surfaces. To amplify the signal, we introduced a liposome, containing ruthenium molecules trapped in the core, chemically coupled to an antibody specific to the analyte (e.g. Legionella antigen). In the presence of the analyte, immune complexes were formed by antigen-antibody reactions upon addition of the immuno-liposome into a sample. This mixture was then absorbed by the capillary action from the bottom of the membrane strip. The liposome particles in the complexes were carried by a medium through the antigen pad without interaction, while free immuno-liposome was trapped by immune reactions on the pad surfaces. The aqueous medium influx into the glass pad dissolved a detergent pre-located within the compartment and the liposome rupture thereby released ruthenium molecules into the solution. The molecules were oxidized on the electrode surfaces and produced an electro- chemiluminescence (ECL) in proportion to the analyte concentration. The signal generation based on ECL resulted in an exponential dose-response pattern and the analyte detection limit of 2 ng/ml was approximately 10-fold more sensitive than that obtained from a conventional system.

AB - A photometric immunosensor that can be used for on-site diagnosis has been constructed. The sensor system was assembled by partially superimposing a nitrocellulose membrane strip (the lower) containing an immobilized antigen on the surface with a glass fiber membrane strip (the upper) including two electrodes on the opposite surfaces. To amplify the signal, we introduced a liposome, containing ruthenium molecules trapped in the core, chemically coupled to an antibody specific to the analyte (e.g. Legionella antigen). In the presence of the analyte, immune complexes were formed by antigen-antibody reactions upon addition of the immuno-liposome into a sample. This mixture was then absorbed by the capillary action from the bottom of the membrane strip. The liposome particles in the complexes were carried by a medium through the antigen pad without interaction, while free immuno-liposome was trapped by immune reactions on the pad surfaces. The aqueous medium influx into the glass pad dissolved a detergent pre-located within the compartment and the liposome rupture thereby released ruthenium molecules into the solution. The molecules were oxidized on the electrode surfaces and produced an electro- chemiluminescence (ECL) in proportion to the analyte concentration. The signal generation based on ECL resulted in an exponential dose-response pattern and the analyte detection limit of 2 ng/ml was approximately 10-fold more sensitive than that obtained from a conventional system.

KW - Electro-chemiluminescence

KW - Immuno-chromatographic assay

KW - Immuno-liposome

KW - Point-of-care device

KW - Screen-printed electrodes

UR - http://www.scopus.com/inward/record.url?scp=0242570447&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0242570447&partnerID=8YFLogxK

U2 - 10.1016/S0956-5663(03)00207-0

DO - 10.1016/S0956-5663(03)00207-0

M3 - Article

VL - 19

SP - 289

EP - 296

JO - Biosensors

JF - Biosensors

SN - 0956-5663

IS - 4

ER -