Abstract

This study describes the development of a beam monitoring system for the verification of entrance dose map in pencil beam scanning (PBS) proton therapy based on fiber optic radiation sensors (FORS) and the validation of this system through a feasibility study. The beam monitoring system consisted of 128 optical fibers optically coupled to photo-multiplier tubes. The performance of the beam monitoring system based on FORS was verified by comparing 2D dose maps of square-shaped fields of various sizes, which were obtained using conventional dosimeters such as MatriXX and EBT3 film, with those measured using FORS. The resulting full-width at half maximum and penumbra were compared for PBS proton beams, with a ≤2% difference between each value, indicating that measurements using the conventional dosimetric tool corresponded to measurements based on FORS. For irregularly-shaped fields, a comparison based on the gamma index between 2D dose maps obtained using MatriXX and EBT3 film and the 2D dose map measured by the FORS showed passing rates of 96.9 ± 1.3% and 96.2 ± 1.9%, respectively, confirming that FORS-based measurements for PBS proton therapy agreed well with those measured using the conventional dosimetric tools. These results demonstrate that the developed beam monitoring system based on FORS is good candidate for monitoring the entrance dose map in PBS proton therapy.

Original languageEnglish
Article number227
JournalSensors (Switzerland)
Volume18
Issue number1
DOIs
Publication statusPublished - 2018 Jan 15

Fingerprint

Optical Fibers
pencil beams
Proton beams
proton beams
entrances
Fiber optics
Protons
Optical fibers
fiber optics
optical fibers
Radiation
Scanning
dosage
Proton Therapy
scanning
sensors
Sensors
radiation
Dosimetry
Monitoring

Keywords

  • Beam monitoring system
  • Fiber-optic
  • Pencil beam scanning
  • Proton therapy

ASJC Scopus subject areas

  • Analytical Chemistry
  • Atomic and Molecular Physics, and Optics
  • Biochemistry
  • Instrumentation
  • Electrical and Electronic Engineering

Cite this

Development of optical fiber based measurement system for the verification of entrance dose map in pencil beam scanning proton beam. / Son, Jaeman; Lee, Se Byeong; Lim, Youngkyung; Park, Sung Yong; Cho, Kwanho; Yoon, Myonggeun; Shin, Dongho.

In: Sensors (Switzerland), Vol. 18, No. 1, 227, 15.01.2018.

Research output: Contribution to journalArticle

Son, Jaeman ; Lee, Se Byeong ; Lim, Youngkyung ; Park, Sung Yong ; Cho, Kwanho ; Yoon, Myonggeun ; Shin, Dongho. / Development of optical fiber based measurement system for the verification of entrance dose map in pencil beam scanning proton beam. In: Sensors (Switzerland). 2018 ; Vol. 18, No. 1.
@article{53381eb4bc8f4e8185e53eccf2d63f1d,
title = "Development of optical fiber based measurement system for the verification of entrance dose map in pencil beam scanning proton beam",
abstract = "This study describes the development of a beam monitoring system for the verification of entrance dose map in pencil beam scanning (PBS) proton therapy based on fiber optic radiation sensors (FORS) and the validation of this system through a feasibility study. The beam monitoring system consisted of 128 optical fibers optically coupled to photo-multiplier tubes. The performance of the beam monitoring system based on FORS was verified by comparing 2D dose maps of square-shaped fields of various sizes, which were obtained using conventional dosimeters such as MatriXX and EBT3 film, with those measured using FORS. The resulting full-width at half maximum and penumbra were compared for PBS proton beams, with a ≤2{\%} difference between each value, indicating that measurements using the conventional dosimetric tool corresponded to measurements based on FORS. For irregularly-shaped fields, a comparison based on the gamma index between 2D dose maps obtained using MatriXX and EBT3 film and the 2D dose map measured by the FORS showed passing rates of 96.9 ± 1.3{\%} and 96.2 ± 1.9{\%}, respectively, confirming that FORS-based measurements for PBS proton therapy agreed well with those measured using the conventional dosimetric tools. These results demonstrate that the developed beam monitoring system based on FORS is good candidate for monitoring the entrance dose map in PBS proton therapy.",
keywords = "Beam monitoring system, Fiber-optic, Pencil beam scanning, Proton therapy",
author = "Jaeman Son and Lee, {Se Byeong} and Youngkyung Lim and Park, {Sung Yong} and Kwanho Cho and Myonggeun Yoon and Dongho Shin",
year = "2018",
month = "1",
day = "15",
doi = "10.3390/s18010227",
language = "English",
volume = "18",
journal = "Sensors (Switzerland)",
issn = "1424-8220",
publisher = "Multidisciplinary Digital Publishing Institute (MDPI)",
number = "1",

}

TY - JOUR

T1 - Development of optical fiber based measurement system for the verification of entrance dose map in pencil beam scanning proton beam

AU - Son, Jaeman

AU - Lee, Se Byeong

AU - Lim, Youngkyung

AU - Park, Sung Yong

AU - Cho, Kwanho

AU - Yoon, Myonggeun

AU - Shin, Dongho

PY - 2018/1/15

Y1 - 2018/1/15

N2 - This study describes the development of a beam monitoring system for the verification of entrance dose map in pencil beam scanning (PBS) proton therapy based on fiber optic radiation sensors (FORS) and the validation of this system through a feasibility study. The beam monitoring system consisted of 128 optical fibers optically coupled to photo-multiplier tubes. The performance of the beam monitoring system based on FORS was verified by comparing 2D dose maps of square-shaped fields of various sizes, which were obtained using conventional dosimeters such as MatriXX and EBT3 film, with those measured using FORS. The resulting full-width at half maximum and penumbra were compared for PBS proton beams, with a ≤2% difference between each value, indicating that measurements using the conventional dosimetric tool corresponded to measurements based on FORS. For irregularly-shaped fields, a comparison based on the gamma index between 2D dose maps obtained using MatriXX and EBT3 film and the 2D dose map measured by the FORS showed passing rates of 96.9 ± 1.3% and 96.2 ± 1.9%, respectively, confirming that FORS-based measurements for PBS proton therapy agreed well with those measured using the conventional dosimetric tools. These results demonstrate that the developed beam monitoring system based on FORS is good candidate for monitoring the entrance dose map in PBS proton therapy.

AB - This study describes the development of a beam monitoring system for the verification of entrance dose map in pencil beam scanning (PBS) proton therapy based on fiber optic radiation sensors (FORS) and the validation of this system through a feasibility study. The beam monitoring system consisted of 128 optical fibers optically coupled to photo-multiplier tubes. The performance of the beam monitoring system based on FORS was verified by comparing 2D dose maps of square-shaped fields of various sizes, which were obtained using conventional dosimeters such as MatriXX and EBT3 film, with those measured using FORS. The resulting full-width at half maximum and penumbra were compared for PBS proton beams, with a ≤2% difference between each value, indicating that measurements using the conventional dosimetric tool corresponded to measurements based on FORS. For irregularly-shaped fields, a comparison based on the gamma index between 2D dose maps obtained using MatriXX and EBT3 film and the 2D dose map measured by the FORS showed passing rates of 96.9 ± 1.3% and 96.2 ± 1.9%, respectively, confirming that FORS-based measurements for PBS proton therapy agreed well with those measured using the conventional dosimetric tools. These results demonstrate that the developed beam monitoring system based on FORS is good candidate for monitoring the entrance dose map in PBS proton therapy.

KW - Beam monitoring system

KW - Fiber-optic

KW - Pencil beam scanning

KW - Proton therapy

UR - http://www.scopus.com/inward/record.url?scp=85040934152&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85040934152&partnerID=8YFLogxK

U2 - 10.3390/s18010227

DO - 10.3390/s18010227

M3 - Article

AN - SCOPUS:85040934152

VL - 18

JO - Sensors (Switzerland)

JF - Sensors (Switzerland)

SN - 1424-8220

IS - 1

M1 - 227

ER -