Dimensional accuracy of ceramic self-ligating brackets and estimates of theoretical torsional play

Youngran Lee, Dong-Yul Lee, Yoon Ji R. Kim

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Objective: To ascertain the dimensional accuracies of some commonly used ceramic self-ligation brackets and the amount of torsional play in various bracket-archwire combinations. Materials and Methods: Four types of 0.022-inch slot ceramic self-ligating brackets (upper right central incisor), three types of 0.018-inch ceramic self-ligating brackets (upper right central incisor), and three types of rectangular archwires (0.016 × 0.022-inch beta-Titanium [TMA] (Ormco, Orange, Calif), 0.016 × 0.022-inch stainless steel [SS] (Ortho Technology, Tampa, Fla), and 0.019 × 0.025-inch SS (Ortho Technology)) were measured using a stereomicroscope to determine slot widths and wire cross-sectional dimensions. The mean acquired dimensions of the brackets and wires were applied to an equation devised by Meling to estimate torsional play angle (γ). Results: In all bracket systems, the slot tops were significantly wider than the slot bases (P <.001), yielding a divergent slot profile. Clarity-SLs (3M Unitek, Monrovia, Calif) showed the greatest divergence among the 0.022-inch brackets, and Clippy-Cs (Tomy, Futaba, Fukushima, Japan) among the 0.018-inch brackets. The Damon Clear (Ormco) bracket had the smallest dimensional error (0.542%), whereas the 0.022-inch Empower Clear (American Orthodontics, Sheboygan, Wis) bracket had the largest (3.585%). Conclusions: The largest amount of theoretical play is observed using the Empower Clear (American Orthodontics) 0.022-inch bracket combined with the 0.016 3 0.022-inch TMA wire (Ormco), whereas the least amount occurs using the 0.018 Clippy-C (Tomy) combined with 0.016 3 0.022-inch SS wire (Ortho Technology).

Original languageEnglish
Pages (from-to)804-809
Number of pages6
JournalAngle Orthodontist
Volume86
Issue number5
DOIs
Publication statusPublished - 2016 Sep 1

Fingerprint

Stainless Steel
Ceramics
Incisor
Orthodontics
Technology
Ligation
Japan

Keywords

  • Ceramic self-ligating brackets
  • Slot dimensions
  • Torsional play

ASJC Scopus subject areas

  • Orthodontics

Cite this

Dimensional accuracy of ceramic self-ligating brackets and estimates of theoretical torsional play. / Lee, Youngran; Lee, Dong-Yul; Kim, Yoon Ji R.

In: Angle Orthodontist, Vol. 86, No. 5, 01.09.2016, p. 804-809.

Research output: Contribution to journalArticle

@article{1ea475346769402cba75d46287ea80b2,
title = "Dimensional accuracy of ceramic self-ligating brackets and estimates of theoretical torsional play",
abstract = "Objective: To ascertain the dimensional accuracies of some commonly used ceramic self-ligation brackets and the amount of torsional play in various bracket-archwire combinations. Materials and Methods: Four types of 0.022-inch slot ceramic self-ligating brackets (upper right central incisor), three types of 0.018-inch ceramic self-ligating brackets (upper right central incisor), and three types of rectangular archwires (0.016 × 0.022-inch beta-Titanium [TMA] (Ormco, Orange, Calif), 0.016 × 0.022-inch stainless steel [SS] (Ortho Technology, Tampa, Fla), and 0.019 × 0.025-inch SS (Ortho Technology)) were measured using a stereomicroscope to determine slot widths and wire cross-sectional dimensions. The mean acquired dimensions of the brackets and wires were applied to an equation devised by Meling to estimate torsional play angle (γ). Results: In all bracket systems, the slot tops were significantly wider than the slot bases (P <.001), yielding a divergent slot profile. Clarity-SLs (3M Unitek, Monrovia, Calif) showed the greatest divergence among the 0.022-inch brackets, and Clippy-Cs (Tomy, Futaba, Fukushima, Japan) among the 0.018-inch brackets. The Damon Clear (Ormco) bracket had the smallest dimensional error (0.542{\%}), whereas the 0.022-inch Empower Clear (American Orthodontics, Sheboygan, Wis) bracket had the largest (3.585{\%}). Conclusions: The largest amount of theoretical play is observed using the Empower Clear (American Orthodontics) 0.022-inch bracket combined with the 0.016 3 0.022-inch TMA wire (Ormco), whereas the least amount occurs using the 0.018 Clippy-C (Tomy) combined with 0.016 3 0.022-inch SS wire (Ortho Technology).",
keywords = "Ceramic self-ligating brackets, Slot dimensions, Torsional play",
author = "Youngran Lee and Dong-Yul Lee and Kim, {Yoon Ji R.}",
year = "2016",
month = "9",
day = "1",
doi = "10.2319/092415-647.1",
language = "English",
volume = "86",
pages = "804--809",
journal = "Angle Orthodontist",
issn = "0003-3219",
publisher = "E H Angle Orthodontists Research & Education Foundation, Inc.",
number = "5",

}

TY - JOUR

T1 - Dimensional accuracy of ceramic self-ligating brackets and estimates of theoretical torsional play

AU - Lee, Youngran

AU - Lee, Dong-Yul

AU - Kim, Yoon Ji R.

PY - 2016/9/1

Y1 - 2016/9/1

N2 - Objective: To ascertain the dimensional accuracies of some commonly used ceramic self-ligation brackets and the amount of torsional play in various bracket-archwire combinations. Materials and Methods: Four types of 0.022-inch slot ceramic self-ligating brackets (upper right central incisor), three types of 0.018-inch ceramic self-ligating brackets (upper right central incisor), and three types of rectangular archwires (0.016 × 0.022-inch beta-Titanium [TMA] (Ormco, Orange, Calif), 0.016 × 0.022-inch stainless steel [SS] (Ortho Technology, Tampa, Fla), and 0.019 × 0.025-inch SS (Ortho Technology)) were measured using a stereomicroscope to determine slot widths and wire cross-sectional dimensions. The mean acquired dimensions of the brackets and wires were applied to an equation devised by Meling to estimate torsional play angle (γ). Results: In all bracket systems, the slot tops were significantly wider than the slot bases (P <.001), yielding a divergent slot profile. Clarity-SLs (3M Unitek, Monrovia, Calif) showed the greatest divergence among the 0.022-inch brackets, and Clippy-Cs (Tomy, Futaba, Fukushima, Japan) among the 0.018-inch brackets. The Damon Clear (Ormco) bracket had the smallest dimensional error (0.542%), whereas the 0.022-inch Empower Clear (American Orthodontics, Sheboygan, Wis) bracket had the largest (3.585%). Conclusions: The largest amount of theoretical play is observed using the Empower Clear (American Orthodontics) 0.022-inch bracket combined with the 0.016 3 0.022-inch TMA wire (Ormco), whereas the least amount occurs using the 0.018 Clippy-C (Tomy) combined with 0.016 3 0.022-inch SS wire (Ortho Technology).

AB - Objective: To ascertain the dimensional accuracies of some commonly used ceramic self-ligation brackets and the amount of torsional play in various bracket-archwire combinations. Materials and Methods: Four types of 0.022-inch slot ceramic self-ligating brackets (upper right central incisor), three types of 0.018-inch ceramic self-ligating brackets (upper right central incisor), and three types of rectangular archwires (0.016 × 0.022-inch beta-Titanium [TMA] (Ormco, Orange, Calif), 0.016 × 0.022-inch stainless steel [SS] (Ortho Technology, Tampa, Fla), and 0.019 × 0.025-inch SS (Ortho Technology)) were measured using a stereomicroscope to determine slot widths and wire cross-sectional dimensions. The mean acquired dimensions of the brackets and wires were applied to an equation devised by Meling to estimate torsional play angle (γ). Results: In all bracket systems, the slot tops were significantly wider than the slot bases (P <.001), yielding a divergent slot profile. Clarity-SLs (3M Unitek, Monrovia, Calif) showed the greatest divergence among the 0.022-inch brackets, and Clippy-Cs (Tomy, Futaba, Fukushima, Japan) among the 0.018-inch brackets. The Damon Clear (Ormco) bracket had the smallest dimensional error (0.542%), whereas the 0.022-inch Empower Clear (American Orthodontics, Sheboygan, Wis) bracket had the largest (3.585%). Conclusions: The largest amount of theoretical play is observed using the Empower Clear (American Orthodontics) 0.022-inch bracket combined with the 0.016 3 0.022-inch TMA wire (Ormco), whereas the least amount occurs using the 0.018 Clippy-C (Tomy) combined with 0.016 3 0.022-inch SS wire (Ortho Technology).

KW - Ceramic self-ligating brackets

KW - Slot dimensions

KW - Torsional play

UR - http://www.scopus.com/inward/record.url?scp=84984687973&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84984687973&partnerID=8YFLogxK

U2 - 10.2319/092415-647.1

DO - 10.2319/092415-647.1

M3 - Article

VL - 86

SP - 804

EP - 809

JO - Angle Orthodontist

JF - Angle Orthodontist

SN - 0003-3219

IS - 5

ER -