Effect of air handler supply air temperature in VAV system on building energy consumption under Korean climatic condition

Kwang Ho Lee, Kyung Chin, Jin Woo Moon

Research output: Chapter in Book/Report/Conference proceedingChapter

Abstract

Variable Air Volume (VAV) unit system is one of the commonly used forced-air heating and cooling systems in typical office buildings. Literally, it adjusts the supply airflow from the central Air Handling Unit (AHU) to meet the heating and cooling load of the building, while the AHU Supply Air Temperature (SAT) is usually fixed. This AHU SAT has significant impacts on the overall VAV system energy performance. In this study, the detailed analysis of the impact of AHU SAT in the conventional VAV system was performed in the typical office building prototype under Korean climatic condition using the whole-building energy simulation software platform, EnergyPlus version 7.1. Three different AHU SATs were investigated in this study: AHU SAT set-point of 13.9C, 15.6C and 17.2C. It was observed that increasing AHU SAT raised the fan energy, while reducing the heating and cooling energy. Due to the fact that the amount of heating and cooling energy reduction was larger than that of the fan energy increase, the total HVAC energy consumption slight decreased with the higher SAT.

Original languageEnglish
Title of host publicationAdvances in Civil Engineering and Building Materials
PublisherCRC Press
Pages395-398
Number of pages4
ISBN (Electronic)9780203388075
ISBN (Print)9780415643429
DOIs
Publication statusPublished - 2012 Jan 1
Externally publishedYes

Fingerprint

Energy utilization
Air
Temperature
Heating
Office buildings
Cooling
Fans
Cooling systems

Keywords

  • Building energy consumption
  • Damage Supply air temperature
  • Energy plus
  • VAV system

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Lee, K. H., Chin, K., & Moon, J. W. (2012). Effect of air handler supply air temperature in VAV system on building energy consumption under Korean climatic condition. In Advances in Civil Engineering and Building Materials (pp. 395-398). CRC Press. https://doi.org/10.1201/b13165

Effect of air handler supply air temperature in VAV system on building energy consumption under Korean climatic condition. / Lee, Kwang Ho; Chin, Kyung; Moon, Jin Woo.

Advances in Civil Engineering and Building Materials. CRC Press, 2012. p. 395-398.

Research output: Chapter in Book/Report/Conference proceedingChapter

Lee, KH, Chin, K & Moon, JW 2012, Effect of air handler supply air temperature in VAV system on building energy consumption under Korean climatic condition. in Advances in Civil Engineering and Building Materials. CRC Press, pp. 395-398. https://doi.org/10.1201/b13165
Lee KH, Chin K, Moon JW. Effect of air handler supply air temperature in VAV system on building energy consumption under Korean climatic condition. In Advances in Civil Engineering and Building Materials. CRC Press. 2012. p. 395-398 https://doi.org/10.1201/b13165
Lee, Kwang Ho ; Chin, Kyung ; Moon, Jin Woo. / Effect of air handler supply air temperature in VAV system on building energy consumption under Korean climatic condition. Advances in Civil Engineering and Building Materials. CRC Press, 2012. pp. 395-398
@inbook{028dff01836d4e6595e2837402fd4b4a,
title = "Effect of air handler supply air temperature in VAV system on building energy consumption under Korean climatic condition",
abstract = "Variable Air Volume (VAV) unit system is one of the commonly used forced-air heating and cooling systems in typical office buildings. Literally, it adjusts the supply airflow from the central Air Handling Unit (AHU) to meet the heating and cooling load of the building, while the AHU Supply Air Temperature (SAT) is usually fixed. This AHU SAT has significant impacts on the overall VAV system energy performance. In this study, the detailed analysis of the impact of AHU SAT in the conventional VAV system was performed in the typical office building prototype under Korean climatic condition using the whole-building energy simulation software platform, EnergyPlus version 7.1. Three different AHU SATs were investigated in this study: AHU SAT set-point of 13.9◦C, 15.6◦C and 17.2◦C. It was observed that increasing AHU SAT raised the fan energy, while reducing the heating and cooling energy. Due to the fact that the amount of heating and cooling energy reduction was larger than that of the fan energy increase, the total HVAC energy consumption slight decreased with the higher SAT.",
keywords = "Building energy consumption, Damage Supply air temperature, Energy plus, VAV system",
author = "Lee, {Kwang Ho} and Kyung Chin and Moon, {Jin Woo}",
year = "2012",
month = "1",
day = "1",
doi = "10.1201/b13165",
language = "English",
isbn = "9780415643429",
pages = "395--398",
booktitle = "Advances in Civil Engineering and Building Materials",
publisher = "CRC Press",

}

TY - CHAP

T1 - Effect of air handler supply air temperature in VAV system on building energy consumption under Korean climatic condition

AU - Lee, Kwang Ho

AU - Chin, Kyung

AU - Moon, Jin Woo

PY - 2012/1/1

Y1 - 2012/1/1

N2 - Variable Air Volume (VAV) unit system is one of the commonly used forced-air heating and cooling systems in typical office buildings. Literally, it adjusts the supply airflow from the central Air Handling Unit (AHU) to meet the heating and cooling load of the building, while the AHU Supply Air Temperature (SAT) is usually fixed. This AHU SAT has significant impacts on the overall VAV system energy performance. In this study, the detailed analysis of the impact of AHU SAT in the conventional VAV system was performed in the typical office building prototype under Korean climatic condition using the whole-building energy simulation software platform, EnergyPlus version 7.1. Three different AHU SATs were investigated in this study: AHU SAT set-point of 13.9◦C, 15.6◦C and 17.2◦C. It was observed that increasing AHU SAT raised the fan energy, while reducing the heating and cooling energy. Due to the fact that the amount of heating and cooling energy reduction was larger than that of the fan energy increase, the total HVAC energy consumption slight decreased with the higher SAT.

AB - Variable Air Volume (VAV) unit system is one of the commonly used forced-air heating and cooling systems in typical office buildings. Literally, it adjusts the supply airflow from the central Air Handling Unit (AHU) to meet the heating and cooling load of the building, while the AHU Supply Air Temperature (SAT) is usually fixed. This AHU SAT has significant impacts on the overall VAV system energy performance. In this study, the detailed analysis of the impact of AHU SAT in the conventional VAV system was performed in the typical office building prototype under Korean climatic condition using the whole-building energy simulation software platform, EnergyPlus version 7.1. Three different AHU SATs were investigated in this study: AHU SAT set-point of 13.9◦C, 15.6◦C and 17.2◦C. It was observed that increasing AHU SAT raised the fan energy, while reducing the heating and cooling energy. Due to the fact that the amount of heating and cooling energy reduction was larger than that of the fan energy increase, the total HVAC energy consumption slight decreased with the higher SAT.

KW - Building energy consumption

KW - Damage Supply air temperature

KW - Energy plus

KW - VAV system

UR - http://www.scopus.com/inward/record.url?scp=85055806379&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85055806379&partnerID=8YFLogxK

U2 - 10.1201/b13165

DO - 10.1201/b13165

M3 - Chapter

AN - SCOPUS:85055806379

SN - 9780415643429

SP - 395

EP - 398

BT - Advances in Civil Engineering and Building Materials

PB - CRC Press

ER -