Effect of flow rate variation on the frequency response in slot coating process with different upstream sloped die geometries

Won Gi Ahn, Si Hyung Lee, Jaewook Nam, Hyun Wook Jung

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

The sensitivity of slot coating process with different sloped upstream die configurations has been investigated using the viscocapillary model for a coating liquid with constant viscosity (Newtonian) through frequency response technique. Amplitude ratios of coating thickness with respect to a sinusoidal disturbance at flow rate are compared under different input frequency and upstream die lip angle conditions. Amplitude ratio values decrease as the upstream die lip angle increases, implying that the coating system is less sensitive to the given disturbance due to the larger space condition in the upstream die region. Amplitude ratio curves obtained from various conditions can be usefully unified in a single one with the help of new dimensionless time between fluid time scale in upstream region and perturbed time scale by input frequency.

Original languageEnglish
Article numberA020
Pages (from-to)1218-1221
Number of pages4
JournalKorean Journal of Chemical Engineering
Volume32
Issue number7
DOIs
Publication statusPublished - 2015 Jun 1

Fingerprint

Frequency response
Flow rate
Coatings
Geometry
Viscosity
Fluids
Liquids

Keywords

  • Frequency Response
  • Operability Coating Window
  • REFERENCES
  • Sensitivity
  • Sloped Slot Die
  • Slot Coating

ASJC Scopus subject areas

  • Chemistry(all)
  • Chemical Engineering(all)

Cite this

Effect of flow rate variation on the frequency response in slot coating process with different upstream sloped die geometries. / Ahn, Won Gi; Lee, Si Hyung; Nam, Jaewook; Jung, Hyun Wook.

In: Korean Journal of Chemical Engineering, Vol. 32, No. 7, A020, 01.06.2015, p. 1218-1221.

Research output: Contribution to journalArticle

@article{f0b722c3959a481282200c2119f225fd,
title = "Effect of flow rate variation on the frequency response in slot coating process with different upstream sloped die geometries",
abstract = "The sensitivity of slot coating process with different sloped upstream die configurations has been investigated using the viscocapillary model for a coating liquid with constant viscosity (Newtonian) through frequency response technique. Amplitude ratios of coating thickness with respect to a sinusoidal disturbance at flow rate are compared under different input frequency and upstream die lip angle conditions. Amplitude ratio values decrease as the upstream die lip angle increases, implying that the coating system is less sensitive to the given disturbance due to the larger space condition in the upstream die region. Amplitude ratio curves obtained from various conditions can be usefully unified in a single one with the help of new dimensionless time between fluid time scale in upstream region and perturbed time scale by input frequency.",
keywords = "Frequency Response, Operability Coating Window, REFERENCES, Sensitivity, Sloped Slot Die, Slot Coating",
author = "Ahn, {Won Gi} and Lee, {Si Hyung} and Jaewook Nam and Jung, {Hyun Wook}",
year = "2015",
month = "6",
day = "1",
doi = "10.1007/s11814-015-0079-x",
language = "English",
volume = "32",
pages = "1218--1221",
journal = "Korean Journal of Chemical Engineering",
issn = "0256-1115",
publisher = "Springer New York",
number = "7",

}

TY - JOUR

T1 - Effect of flow rate variation on the frequency response in slot coating process with different upstream sloped die geometries

AU - Ahn, Won Gi

AU - Lee, Si Hyung

AU - Nam, Jaewook

AU - Jung, Hyun Wook

PY - 2015/6/1

Y1 - 2015/6/1

N2 - The sensitivity of slot coating process with different sloped upstream die configurations has been investigated using the viscocapillary model for a coating liquid with constant viscosity (Newtonian) through frequency response technique. Amplitude ratios of coating thickness with respect to a sinusoidal disturbance at flow rate are compared under different input frequency and upstream die lip angle conditions. Amplitude ratio values decrease as the upstream die lip angle increases, implying that the coating system is less sensitive to the given disturbance due to the larger space condition in the upstream die region. Amplitude ratio curves obtained from various conditions can be usefully unified in a single one with the help of new dimensionless time between fluid time scale in upstream region and perturbed time scale by input frequency.

AB - The sensitivity of slot coating process with different sloped upstream die configurations has been investigated using the viscocapillary model for a coating liquid with constant viscosity (Newtonian) through frequency response technique. Amplitude ratios of coating thickness with respect to a sinusoidal disturbance at flow rate are compared under different input frequency and upstream die lip angle conditions. Amplitude ratio values decrease as the upstream die lip angle increases, implying that the coating system is less sensitive to the given disturbance due to the larger space condition in the upstream die region. Amplitude ratio curves obtained from various conditions can be usefully unified in a single one with the help of new dimensionless time between fluid time scale in upstream region and perturbed time scale by input frequency.

KW - Frequency Response

KW - Operability Coating Window

KW - REFERENCES

KW - Sensitivity

KW - Sloped Slot Die

KW - Slot Coating

UR - http://www.scopus.com/inward/record.url?scp=84943348543&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84943348543&partnerID=8YFLogxK

U2 - 10.1007/s11814-015-0079-x

DO - 10.1007/s11814-015-0079-x

M3 - Article

AN - SCOPUS:84943348543

VL - 32

SP - 1218

EP - 1221

JO - Korean Journal of Chemical Engineering

JF - Korean Journal of Chemical Engineering

SN - 0256-1115

IS - 7

M1 - A020

ER -