Effect of intervening ferromagnet on spin accumulation in Py/Au/Py spin valve device

Janghae Ku, Joonyeon Chang, Jonghwa Eom, Suk Hee Han, Gyu-Tae Kim

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Nonlocal spin signal is largely dependent on the resistivity of nonmagnetic channel in spin valve devices. Since the resistivity of channel is subjected to change from sample to sample, it is necessary to keep the resistivity as constant as possible. Multiferromagnetic electrodes on single channel are favorable in order to minimize the variation of the resistivity. There is controversial that intervening ferromagnetic electrode may affect spin signal in such a structure. In this experiment, we fabricated Py/Au/Py spin valve devices with multi Py electrodes and measured series of nonlocal signal in various distances of Pys with or without intervening Py electrode aiming at clarifying the controversy.

Original languageEnglish
Title of host publication2006 IEEE Nanotechnology Materials and Devices Conference, NMDC
Pages602-603
Number of pages2
Volume1
DOIs
Publication statusPublished - 2006 Dec 1
Event2006 IEEE Nanotechnology Materials and Devices Conference, NMDC - Gyeongju, Korea, Republic of
Duration: 2006 Oct 222006 Oct 25

Other

Other2006 IEEE Nanotechnology Materials and Devices Conference, NMDC
CountryKorea, Republic of
CityGyeongju
Period06/10/2206/10/25

Fingerprint

Electrodes
Electron tubes
Experiments

Keywords

  • Intervening ferromagnet
  • Nonlocal spin signal
  • Spin accumulation
  • Spin injection
  • Spin valve device

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Materials Science(all)

Cite this

Ku, J., Chang, J., Eom, J., Han, S. H., & Kim, G-T. (2006). Effect of intervening ferromagnet on spin accumulation in Py/Au/Py spin valve device. In 2006 IEEE Nanotechnology Materials and Devices Conference, NMDC (Vol. 1, pp. 602-603). [4388923] https://doi.org/10.1109/NMDC.2006.4388923

Effect of intervening ferromagnet on spin accumulation in Py/Au/Py spin valve device. / Ku, Janghae; Chang, Joonyeon; Eom, Jonghwa; Han, Suk Hee; Kim, Gyu-Tae.

2006 IEEE Nanotechnology Materials and Devices Conference, NMDC. Vol. 1 2006. p. 602-603 4388923.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Ku, J, Chang, J, Eom, J, Han, SH & Kim, G-T 2006, Effect of intervening ferromagnet on spin accumulation in Py/Au/Py spin valve device. in 2006 IEEE Nanotechnology Materials and Devices Conference, NMDC. vol. 1, 4388923, pp. 602-603, 2006 IEEE Nanotechnology Materials and Devices Conference, NMDC, Gyeongju, Korea, Republic of, 06/10/22. https://doi.org/10.1109/NMDC.2006.4388923
Ku J, Chang J, Eom J, Han SH, Kim G-T. Effect of intervening ferromagnet on spin accumulation in Py/Au/Py spin valve device. In 2006 IEEE Nanotechnology Materials and Devices Conference, NMDC. Vol. 1. 2006. p. 602-603. 4388923 https://doi.org/10.1109/NMDC.2006.4388923
Ku, Janghae ; Chang, Joonyeon ; Eom, Jonghwa ; Han, Suk Hee ; Kim, Gyu-Tae. / Effect of intervening ferromagnet on spin accumulation in Py/Au/Py spin valve device. 2006 IEEE Nanotechnology Materials and Devices Conference, NMDC. Vol. 1 2006. pp. 602-603
@inproceedings{4beed0b262134d0d94f4e530b63a7c7f,
title = "Effect of intervening ferromagnet on spin accumulation in Py/Au/Py spin valve device",
abstract = "Nonlocal spin signal is largely dependent on the resistivity of nonmagnetic channel in spin valve devices. Since the resistivity of channel is subjected to change from sample to sample, it is necessary to keep the resistivity as constant as possible. Multiferromagnetic electrodes on single channel are favorable in order to minimize the variation of the resistivity. There is controversial that intervening ferromagnetic electrode may affect spin signal in such a structure. In this experiment, we fabricated Py/Au/Py spin valve devices with multi Py electrodes and measured series of nonlocal signal in various distances of Pys with or without intervening Py electrode aiming at clarifying the controversy.",
keywords = "Intervening ferromagnet, Nonlocal spin signal, Spin accumulation, Spin injection, Spin valve device",
author = "Janghae Ku and Joonyeon Chang and Jonghwa Eom and Han, {Suk Hee} and Gyu-Tae Kim",
year = "2006",
month = "12",
day = "1",
doi = "10.1109/NMDC.2006.4388923",
language = "English",
isbn = "1424405408",
volume = "1",
pages = "602--603",
booktitle = "2006 IEEE Nanotechnology Materials and Devices Conference, NMDC",

}

TY - GEN

T1 - Effect of intervening ferromagnet on spin accumulation in Py/Au/Py spin valve device

AU - Ku, Janghae

AU - Chang, Joonyeon

AU - Eom, Jonghwa

AU - Han, Suk Hee

AU - Kim, Gyu-Tae

PY - 2006/12/1

Y1 - 2006/12/1

N2 - Nonlocal spin signal is largely dependent on the resistivity of nonmagnetic channel in spin valve devices. Since the resistivity of channel is subjected to change from sample to sample, it is necessary to keep the resistivity as constant as possible. Multiferromagnetic electrodes on single channel are favorable in order to minimize the variation of the resistivity. There is controversial that intervening ferromagnetic electrode may affect spin signal in such a structure. In this experiment, we fabricated Py/Au/Py spin valve devices with multi Py electrodes and measured series of nonlocal signal in various distances of Pys with or without intervening Py electrode aiming at clarifying the controversy.

AB - Nonlocal spin signal is largely dependent on the resistivity of nonmagnetic channel in spin valve devices. Since the resistivity of channel is subjected to change from sample to sample, it is necessary to keep the resistivity as constant as possible. Multiferromagnetic electrodes on single channel are favorable in order to minimize the variation of the resistivity. There is controversial that intervening ferromagnetic electrode may affect spin signal in such a structure. In this experiment, we fabricated Py/Au/Py spin valve devices with multi Py electrodes and measured series of nonlocal signal in various distances of Pys with or without intervening Py electrode aiming at clarifying the controversy.

KW - Intervening ferromagnet

KW - Nonlocal spin signal

KW - Spin accumulation

KW - Spin injection

KW - Spin valve device

UR - http://www.scopus.com/inward/record.url?scp=50249098599&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=50249098599&partnerID=8YFLogxK

U2 - 10.1109/NMDC.2006.4388923

DO - 10.1109/NMDC.2006.4388923

M3 - Conference contribution

AN - SCOPUS:50249098599

SN - 1424405408

SN - 9781424405404

VL - 1

SP - 602

EP - 603

BT - 2006 IEEE Nanotechnology Materials and Devices Conference, NMDC

ER -