Effect of thermal interference on energy piles considering various configurations of heat exchangers

Sangwoo Park, Seokjae Lee, Dongseop Lee, Dongwook Ahn, Hangseok Choi

Research output: Contribution to journalArticle

Abstract

In general, the design of closed-loop vertical ground heat exchangers (GHEXs) is to determine the required borehole length for providing the heating and cooling load of a target building. However, the same design procedure cannot be applied to the cast-in-place energy pile since the configuration of the heat exchange pipe inside the pile is too varied and the size of the borehole is relatively large. In this paper, the effect of configuration and denseness of heat exchange pipe inside the energy pile was experimentally and numerically evaluated comparing with conventional GHEXs. First, field experiments were performed for six cast-in-place energy piles constructed in a test bed. The results showed that the cast-in-place energy piles could provide higher thermal performance per unit borehole length than the other conventional types of GHEXs by increasing the heat exchange area along with much longer heat exchange pipes. However, the over-tight layout diminished the improvement of thermal performance due to thermal interference between each pipe loop. In addition, the long-term thermal behavior of energy piles and changes in ground temperature were estimated with numerical simulations. With the simulation results, a design chart was provided for evaluating the effect of thermal interference on energy pile performance.

Original languageEnglish
Pages (from-to)381-401
Number of pages21
JournalEnergy and Buildings
Volume199
DOIs
Publication statusPublished - 2019 Sep 15

Fingerprint

Piles
Heat exchangers
Boreholes
Pipe
Hot Temperature
Cooling
Heating
Computer simulation

Keywords

  • Cast-in-place energy pile
  • Design chart
  • Heat exchange rate
  • Thermal interference
  • Thermal performance

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Building and Construction
  • Mechanical Engineering
  • Electrical and Electronic Engineering

Cite this

Effect of thermal interference on energy piles considering various configurations of heat exchangers. / Park, Sangwoo; Lee, Seokjae; Lee, Dongseop; Ahn, Dongwook; Choi, Hangseok.

In: Energy and Buildings, Vol. 199, 15.09.2019, p. 381-401.

Research output: Contribution to journalArticle

Park, Sangwoo ; Lee, Seokjae ; Lee, Dongseop ; Ahn, Dongwook ; Choi, Hangseok. / Effect of thermal interference on energy piles considering various configurations of heat exchangers. In: Energy and Buildings. 2019 ; Vol. 199. pp. 381-401.
@article{69be6061dcb3434f9d58b2a64a98bcce,
title = "Effect of thermal interference on energy piles considering various configurations of heat exchangers",
abstract = "In general, the design of closed-loop vertical ground heat exchangers (GHEXs) is to determine the required borehole length for providing the heating and cooling load of a target building. However, the same design procedure cannot be applied to the cast-in-place energy pile since the configuration of the heat exchange pipe inside the pile is too varied and the size of the borehole is relatively large. In this paper, the effect of configuration and denseness of heat exchange pipe inside the energy pile was experimentally and numerically evaluated comparing with conventional GHEXs. First, field experiments were performed for six cast-in-place energy piles constructed in a test bed. The results showed that the cast-in-place energy piles could provide higher thermal performance per unit borehole length than the other conventional types of GHEXs by increasing the heat exchange area along with much longer heat exchange pipes. However, the over-tight layout diminished the improvement of thermal performance due to thermal interference between each pipe loop. In addition, the long-term thermal behavior of energy piles and changes in ground temperature were estimated with numerical simulations. With the simulation results, a design chart was provided for evaluating the effect of thermal interference on energy pile performance.",
keywords = "Cast-in-place energy pile, Design chart, Heat exchange rate, Thermal interference, Thermal performance",
author = "Sangwoo Park and Seokjae Lee and Dongseop Lee and Dongwook Ahn and Hangseok Choi",
year = "2019",
month = "9",
day = "15",
doi = "10.1016/j.enbuild.2019.07.008",
language = "English",
volume = "199",
pages = "381--401",
journal = "Energy and Buildings",
issn = "0378-7788",
publisher = "Elsevier BV",

}

TY - JOUR

T1 - Effect of thermal interference on energy piles considering various configurations of heat exchangers

AU - Park, Sangwoo

AU - Lee, Seokjae

AU - Lee, Dongseop

AU - Ahn, Dongwook

AU - Choi, Hangseok

PY - 2019/9/15

Y1 - 2019/9/15

N2 - In general, the design of closed-loop vertical ground heat exchangers (GHEXs) is to determine the required borehole length for providing the heating and cooling load of a target building. However, the same design procedure cannot be applied to the cast-in-place energy pile since the configuration of the heat exchange pipe inside the pile is too varied and the size of the borehole is relatively large. In this paper, the effect of configuration and denseness of heat exchange pipe inside the energy pile was experimentally and numerically evaluated comparing with conventional GHEXs. First, field experiments were performed for six cast-in-place energy piles constructed in a test bed. The results showed that the cast-in-place energy piles could provide higher thermal performance per unit borehole length than the other conventional types of GHEXs by increasing the heat exchange area along with much longer heat exchange pipes. However, the over-tight layout diminished the improvement of thermal performance due to thermal interference between each pipe loop. In addition, the long-term thermal behavior of energy piles and changes in ground temperature were estimated with numerical simulations. With the simulation results, a design chart was provided for evaluating the effect of thermal interference on energy pile performance.

AB - In general, the design of closed-loop vertical ground heat exchangers (GHEXs) is to determine the required borehole length for providing the heating and cooling load of a target building. However, the same design procedure cannot be applied to the cast-in-place energy pile since the configuration of the heat exchange pipe inside the pile is too varied and the size of the borehole is relatively large. In this paper, the effect of configuration and denseness of heat exchange pipe inside the energy pile was experimentally and numerically evaluated comparing with conventional GHEXs. First, field experiments were performed for six cast-in-place energy piles constructed in a test bed. The results showed that the cast-in-place energy piles could provide higher thermal performance per unit borehole length than the other conventional types of GHEXs by increasing the heat exchange area along with much longer heat exchange pipes. However, the over-tight layout diminished the improvement of thermal performance due to thermal interference between each pipe loop. In addition, the long-term thermal behavior of energy piles and changes in ground temperature were estimated with numerical simulations. With the simulation results, a design chart was provided for evaluating the effect of thermal interference on energy pile performance.

KW - Cast-in-place energy pile

KW - Design chart

KW - Heat exchange rate

KW - Thermal interference

KW - Thermal performance

UR - http://www.scopus.com/inward/record.url?scp=85068791014&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85068791014&partnerID=8YFLogxK

U2 - 10.1016/j.enbuild.2019.07.008

DO - 10.1016/j.enbuild.2019.07.008

M3 - Article

AN - SCOPUS:85068791014

VL - 199

SP - 381

EP - 401

JO - Energy and Buildings

JF - Energy and Buildings

SN - 0378-7788

ER -