Effect of two-phase fabrication method for the optimum fit of light-polymerized record bases

Jung Bo Huh, Min Goo Kang, Sang-Wan Shin, Jae Jun Ryu

Research output: Contribution to journalArticle

Abstract

PURPOSE. The aims of this study were to suggest a method of fabrication of the record base using a light-polymerized resin by applying the two-phase fabrication method for the improvement of the fit of the record base and to compare the degree of fit according to the separation site. MATERIALS AND METHODS. In the edentulous cast of maxilla, four test groups were considered. In the first, second, third, and fourth test groups (n = 12 in each group) the separation was done at 0, 5, 10, and 15 mm, respectively below the alveolar crest along the palatal plane. For the control group, the record base was made without separating the two sections. The light-body silicone material was injected into the fitting surface of the record base. It was then placed onto the cast and finger pressure was applied to stabilize it in a seated position followed by immediate placement onto the universal test device. Finally, the mass of the impression material was measured after it was removed. ANOVA was performed using the SAS program. For the post-hoc test, the Wilcoxon Rank-Sum test and the Tukey-Kramer HSD test were performed (α= 0.05). RESULTS. The control group and Group 3, 4 showed significant differences. The Group 3 and 4 showed significantly smaller inside gaps than the control group which was not made with the two-phase fabrication method. CONCLUSION. The two-stage polymerized technique can improve the fit of the denture base particularly when the separation was made at 10 to 15 mm from the alveolar crest.

Original languageEnglish
Pages (from-to)102-105
Number of pages4
JournalJournal of Advanced Prosthodontics
Volume2
Issue number3
DOIs
Publication statusPublished - 2010 Dec 1

Fingerprint

Nonparametric Statistics
Light
Control Groups
Denture Bases
Maxilla
Silicones
Posture
Fingers
Analysis of Variance
Pressure
Equipment and Supplies

Keywords

  • Fit
  • Record base
  • Two-stage polymerization

ASJC Scopus subject areas

  • Dentistry (miscellaneous)
  • Oral Surgery

Cite this

Effect of two-phase fabrication method for the optimum fit of light-polymerized record bases. / Huh, Jung Bo; Kang, Min Goo; Shin, Sang-Wan; Ryu, Jae Jun.

In: Journal of Advanced Prosthodontics, Vol. 2, No. 3, 01.12.2010, p. 102-105.

Research output: Contribution to journalArticle

@article{1c85e26457904f2f95f26bdd029c4cb8,
title = "Effect of two-phase fabrication method for the optimum fit of light-polymerized record bases",
abstract = "PURPOSE. The aims of this study were to suggest a method of fabrication of the record base using a light-polymerized resin by applying the two-phase fabrication method for the improvement of the fit of the record base and to compare the degree of fit according to the separation site. MATERIALS AND METHODS. In the edentulous cast of maxilla, four test groups were considered. In the first, second, third, and fourth test groups (n = 12 in each group) the separation was done at 0, 5, 10, and 15 mm, respectively below the alveolar crest along the palatal plane. For the control group, the record base was made without separating the two sections. The light-body silicone material was injected into the fitting surface of the record base. It was then placed onto the cast and finger pressure was applied to stabilize it in a seated position followed by immediate placement onto the universal test device. Finally, the mass of the impression material was measured after it was removed. ANOVA was performed using the SAS program. For the post-hoc test, the Wilcoxon Rank-Sum test and the Tukey-Kramer HSD test were performed (α= 0.05). RESULTS. The control group and Group 3, 4 showed significant differences. The Group 3 and 4 showed significantly smaller inside gaps than the control group which was not made with the two-phase fabrication method. CONCLUSION. The two-stage polymerized technique can improve the fit of the denture base particularly when the separation was made at 10 to 15 mm from the alveolar crest.",
keywords = "Fit, Record base, Two-stage polymerization",
author = "Huh, {Jung Bo} and Kang, {Min Goo} and Sang-Wan Shin and Ryu, {Jae Jun}",
year = "2010",
month = "12",
day = "1",
doi = "10.4047/jap.2010.2.3.102",
language = "English",
volume = "2",
pages = "102--105",
journal = "Journal of Advanced Prosthodontics",
issn = "2005-7806",
publisher = "The Korean Academy of prosthodontics",
number = "3",

}

TY - JOUR

T1 - Effect of two-phase fabrication method for the optimum fit of light-polymerized record bases

AU - Huh, Jung Bo

AU - Kang, Min Goo

AU - Shin, Sang-Wan

AU - Ryu, Jae Jun

PY - 2010/12/1

Y1 - 2010/12/1

N2 - PURPOSE. The aims of this study were to suggest a method of fabrication of the record base using a light-polymerized resin by applying the two-phase fabrication method for the improvement of the fit of the record base and to compare the degree of fit according to the separation site. MATERIALS AND METHODS. In the edentulous cast of maxilla, four test groups were considered. In the first, second, third, and fourth test groups (n = 12 in each group) the separation was done at 0, 5, 10, and 15 mm, respectively below the alveolar crest along the palatal plane. For the control group, the record base was made without separating the two sections. The light-body silicone material was injected into the fitting surface of the record base. It was then placed onto the cast and finger pressure was applied to stabilize it in a seated position followed by immediate placement onto the universal test device. Finally, the mass of the impression material was measured after it was removed. ANOVA was performed using the SAS program. For the post-hoc test, the Wilcoxon Rank-Sum test and the Tukey-Kramer HSD test were performed (α= 0.05). RESULTS. The control group and Group 3, 4 showed significant differences. The Group 3 and 4 showed significantly smaller inside gaps than the control group which was not made with the two-phase fabrication method. CONCLUSION. The two-stage polymerized technique can improve the fit of the denture base particularly when the separation was made at 10 to 15 mm from the alveolar crest.

AB - PURPOSE. The aims of this study were to suggest a method of fabrication of the record base using a light-polymerized resin by applying the two-phase fabrication method for the improvement of the fit of the record base and to compare the degree of fit according to the separation site. MATERIALS AND METHODS. In the edentulous cast of maxilla, four test groups were considered. In the first, second, third, and fourth test groups (n = 12 in each group) the separation was done at 0, 5, 10, and 15 mm, respectively below the alveolar crest along the palatal plane. For the control group, the record base was made without separating the two sections. The light-body silicone material was injected into the fitting surface of the record base. It was then placed onto the cast and finger pressure was applied to stabilize it in a seated position followed by immediate placement onto the universal test device. Finally, the mass of the impression material was measured after it was removed. ANOVA was performed using the SAS program. For the post-hoc test, the Wilcoxon Rank-Sum test and the Tukey-Kramer HSD test were performed (α= 0.05). RESULTS. The control group and Group 3, 4 showed significant differences. The Group 3 and 4 showed significantly smaller inside gaps than the control group which was not made with the two-phase fabrication method. CONCLUSION. The two-stage polymerized technique can improve the fit of the denture base particularly when the separation was made at 10 to 15 mm from the alveolar crest.

KW - Fit

KW - Record base

KW - Two-stage polymerization

UR - http://www.scopus.com/inward/record.url?scp=84883163225&partnerID=8YFLogxK