Effects of anodized implants coated with escherichia coli-derived recombinant human bone morphogenetic protein-2 on osseointegration in rabbits

Jung Bo Huh, Jae Jun Ryu, Jong Eun Kim, Do Wan Kim, Sun Jong Kim, Young Bum Park, Young Su Kim, Su Young Lee, Jeong Yeol Lee, Sang-Wan Shin

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

The aim of the present study was to evaluate the effects of anodized implants coated with Escherichia coli-derived recombinant human bone morphogenetic protein-2 (ErhBMP-2) on osseointegration using stability tests and histometric analysis. Nine adult New Zealand white rabbits (4.5-5 kg) were used in the study. Thirty-six implants (L, 5.0 mm; D, 4.0 mm) were divided into 2 groups: anodized implants (control group) and ErhBMP-2(1.5 mg/ml concentration, 18 μg: Cowellmedi Co, Busan, Korea) coated anodized implant (experimental group). In each rabbit, 4 implants were placed in the tibia on both sides. The control and experimental implants were randomly placed in either left or right tibia. The rabbits were sacrificed at the end of the healing period (2, 4 and 12 weeks after operation). The stability of implants was evaluated by resonance frequency analysis. To obtain histometric results, bone to implant contact (BIC) and intra-thread bone density (ITBD) were measured with a light microscope. The ISQ value was significantly greater in the experimental group than in the control group at 12 weeks (P<0.05). ITBD increased over time in the experimental group (P<0.05). Post hoc comparison test analysis showed that a statistically significant change could be found between 2 and 4 weeks in the interaction between the ITBD change by time lapse and an ErhBMP-2 application condition (P=0.033). In this study, a greater degree of ossointegration was observed in the experimental group. ErhBMP-2 coated anodized implants could be used particularly in cases where bone quality is poor or bone volume is insufficient.

Original languageEnglish
Pages (from-to)62-68
Number of pages7
JournalTissue Engineering and Regenerative Medicine
Volume8
Issue number1
Publication statusPublished - 2011 Jan 1

Fingerprint

Osseointegration
Experimental Implants
Bone Density
Escherichia coli
Bone
Rabbits
Proteins
Tibia
Bone and Bones
Control Groups
Korea
Light
recombinant human bone morphogenetic protein-2
Microscopes

Keywords

  • Anodized implant
  • ErhBMP-2
  • Histometric analysis
  • ISQ
  • Osseointegration

ASJC Scopus subject areas

  • Medicine (miscellaneous)
  • Biomedical Engineering

Cite this

Effects of anodized implants coated with escherichia coli-derived recombinant human bone morphogenetic protein-2 on osseointegration in rabbits. / Huh, Jung Bo; Ryu, Jae Jun; Kim, Jong Eun; Kim, Do Wan; Kim, Sun Jong; Park, Young Bum; Kim, Young Su; Lee, Su Young; Lee, Jeong Yeol; Shin, Sang-Wan.

In: Tissue Engineering and Regenerative Medicine, Vol. 8, No. 1, 01.01.2011, p. 62-68.

Research output: Contribution to journalArticle

Huh, Jung Bo ; Ryu, Jae Jun ; Kim, Jong Eun ; Kim, Do Wan ; Kim, Sun Jong ; Park, Young Bum ; Kim, Young Su ; Lee, Su Young ; Lee, Jeong Yeol ; Shin, Sang-Wan. / Effects of anodized implants coated with escherichia coli-derived recombinant human bone morphogenetic protein-2 on osseointegration in rabbits. In: Tissue Engineering and Regenerative Medicine. 2011 ; Vol. 8, No. 1. pp. 62-68.
@article{50267d16ff984dc59a0e7e1bf8163c38,
title = "Effects of anodized implants coated with escherichia coli-derived recombinant human bone morphogenetic protein-2 on osseointegration in rabbits",
abstract = "The aim of the present study was to evaluate the effects of anodized implants coated with Escherichia coli-derived recombinant human bone morphogenetic protein-2 (ErhBMP-2) on osseointegration using stability tests and histometric analysis. Nine adult New Zealand white rabbits (4.5-5 kg) were used in the study. Thirty-six implants (L, 5.0 mm; D, 4.0 mm) were divided into 2 groups: anodized implants (control group) and ErhBMP-2(1.5 mg/ml concentration, 18 μg: Cowellmedi Co, Busan, Korea) coated anodized implant (experimental group). In each rabbit, 4 implants were placed in the tibia on both sides. The control and experimental implants were randomly placed in either left or right tibia. The rabbits were sacrificed at the end of the healing period (2, 4 and 12 weeks after operation). The stability of implants was evaluated by resonance frequency analysis. To obtain histometric results, bone to implant contact (BIC) and intra-thread bone density (ITBD) were measured with a light microscope. The ISQ value was significantly greater in the experimental group than in the control group at 12 weeks (P<0.05). ITBD increased over time in the experimental group (P<0.05). Post hoc comparison test analysis showed that a statistically significant change could be found between 2 and 4 weeks in the interaction between the ITBD change by time lapse and an ErhBMP-2 application condition (P=0.033). In this study, a greater degree of ossointegration was observed in the experimental group. ErhBMP-2 coated anodized implants could be used particularly in cases where bone quality is poor or bone volume is insufficient.",
keywords = "Anodized implant, ErhBMP-2, Histometric analysis, ISQ, Osseointegration",
author = "Huh, {Jung Bo} and Ryu, {Jae Jun} and Kim, {Jong Eun} and Kim, {Do Wan} and Kim, {Sun Jong} and Park, {Young Bum} and Kim, {Young Su} and Lee, {Su Young} and Lee, {Jeong Yeol} and Sang-Wan Shin",
year = "2011",
month = "1",
day = "1",
language = "English",
volume = "8",
pages = "62--68",
journal = "Tissue Engineering and Regenerative Medicine",
issn = "1738-2696",
publisher = "Springer Science + Business Media",
number = "1",

}

TY - JOUR

T1 - Effects of anodized implants coated with escherichia coli-derived recombinant human bone morphogenetic protein-2 on osseointegration in rabbits

AU - Huh, Jung Bo

AU - Ryu, Jae Jun

AU - Kim, Jong Eun

AU - Kim, Do Wan

AU - Kim, Sun Jong

AU - Park, Young Bum

AU - Kim, Young Su

AU - Lee, Su Young

AU - Lee, Jeong Yeol

AU - Shin, Sang-Wan

PY - 2011/1/1

Y1 - 2011/1/1

N2 - The aim of the present study was to evaluate the effects of anodized implants coated with Escherichia coli-derived recombinant human bone morphogenetic protein-2 (ErhBMP-2) on osseointegration using stability tests and histometric analysis. Nine adult New Zealand white rabbits (4.5-5 kg) were used in the study. Thirty-six implants (L, 5.0 mm; D, 4.0 mm) were divided into 2 groups: anodized implants (control group) and ErhBMP-2(1.5 mg/ml concentration, 18 μg: Cowellmedi Co, Busan, Korea) coated anodized implant (experimental group). In each rabbit, 4 implants were placed in the tibia on both sides. The control and experimental implants were randomly placed in either left or right tibia. The rabbits were sacrificed at the end of the healing period (2, 4 and 12 weeks after operation). The stability of implants was evaluated by resonance frequency analysis. To obtain histometric results, bone to implant contact (BIC) and intra-thread bone density (ITBD) were measured with a light microscope. The ISQ value was significantly greater in the experimental group than in the control group at 12 weeks (P<0.05). ITBD increased over time in the experimental group (P<0.05). Post hoc comparison test analysis showed that a statistically significant change could be found between 2 and 4 weeks in the interaction between the ITBD change by time lapse and an ErhBMP-2 application condition (P=0.033). In this study, a greater degree of ossointegration was observed in the experimental group. ErhBMP-2 coated anodized implants could be used particularly in cases where bone quality is poor or bone volume is insufficient.

AB - The aim of the present study was to evaluate the effects of anodized implants coated with Escherichia coli-derived recombinant human bone morphogenetic protein-2 (ErhBMP-2) on osseointegration using stability tests and histometric analysis. Nine adult New Zealand white rabbits (4.5-5 kg) were used in the study. Thirty-six implants (L, 5.0 mm; D, 4.0 mm) were divided into 2 groups: anodized implants (control group) and ErhBMP-2(1.5 mg/ml concentration, 18 μg: Cowellmedi Co, Busan, Korea) coated anodized implant (experimental group). In each rabbit, 4 implants were placed in the tibia on both sides. The control and experimental implants were randomly placed in either left or right tibia. The rabbits were sacrificed at the end of the healing period (2, 4 and 12 weeks after operation). The stability of implants was evaluated by resonance frequency analysis. To obtain histometric results, bone to implant contact (BIC) and intra-thread bone density (ITBD) were measured with a light microscope. The ISQ value was significantly greater in the experimental group than in the control group at 12 weeks (P<0.05). ITBD increased over time in the experimental group (P<0.05). Post hoc comparison test analysis showed that a statistically significant change could be found between 2 and 4 weeks in the interaction between the ITBD change by time lapse and an ErhBMP-2 application condition (P=0.033). In this study, a greater degree of ossointegration was observed in the experimental group. ErhBMP-2 coated anodized implants could be used particularly in cases where bone quality is poor or bone volume is insufficient.

KW - Anodized implant

KW - ErhBMP-2

KW - Histometric analysis

KW - ISQ

KW - Osseointegration

UR - http://www.scopus.com/inward/record.url?scp=84881469064&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84881469064&partnerID=8YFLogxK

M3 - Article

VL - 8

SP - 62

EP - 68

JO - Tissue Engineering and Regenerative Medicine

JF - Tissue Engineering and Regenerative Medicine

SN - 1738-2696

IS - 1

ER -