Effects of implant drill wear, irrigation, and drill materials on heat generation in osteotomy sites

Ki Tae Koo, Min Ho Kim, Hae-Young Kim, Ulf M E Wikesjö, Jae Ho Yang, In Sung Yeo

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

This study evaluated the effects of drill wear on bone temperature during osteotomy preparation with 3 types of drills and compared heat production between drills. The drills used in this study were titanium nitride-coated metal, tungsten carbide carbon-coated metal, and zirconia ceramic drills. An osteotomy 11 mm in depth was formed in bovine scapular bone following the manufacturer's recommended drill sequences. Drilling was performed without irrigation and repeated 20 times; temperature was measured every 5 times. Next, 200 rounds of drilling during irrigation were performed for each drill, with temperature change monitored until round 200. Analysis of variance statistics were used for analyses of the measured data. Drilling without irrigation showed significant thermal increase at all time points compared to drilling with irrigation (P <.001). No significant difference was found between drill materials. Under irrigation, the frequency of previous drilling had minimal effects on thermal change. The repeated-measures analysis of variance revealed major thermal change at the initial time point (P <.0001), and the multiple comparison tests revealed a significant difference in temperature between the initial drills that had been used 50 or fewer times and those that had been used more than 50 times, irrespective of the drill material. The results of this study indicate that the initial drill should be changed in osteotomy preparation with irrigation after they have been used 50 times. Irrigation may be a more critical factor for the control of temperature elevation than is the drill material.

Original languageEnglish
Pages (from-to)e19-e23
JournalJournal of Oral Implantology
Volume41
Issue number2
DOIs
Publication statusPublished - 2015 Apr 1

Fingerprint

Mandrillus
Osteotomy
Hot Temperature
Temperature
Analysis of Variance
Metals
Bone and Bones
Thermogenesis
Ceramics
Carbon

Keywords

  • Frictional heat
  • Implant drill design
  • Implant drill material
  • Irrigation
  • Surface contact area

ASJC Scopus subject areas

  • Oral Surgery

Cite this

Effects of implant drill wear, irrigation, and drill materials on heat generation in osteotomy sites. / Koo, Ki Tae; Kim, Min Ho; Kim, Hae-Young; Wikesjö, Ulf M E; Yang, Jae Ho; Yeo, In Sung.

In: Journal of Oral Implantology, Vol. 41, No. 2, 01.04.2015, p. e19-e23.

Research output: Contribution to journalArticle

Koo, Ki Tae ; Kim, Min Ho ; Kim, Hae-Young ; Wikesjö, Ulf M E ; Yang, Jae Ho ; Yeo, In Sung. / Effects of implant drill wear, irrigation, and drill materials on heat generation in osteotomy sites. In: Journal of Oral Implantology. 2015 ; Vol. 41, No. 2. pp. e19-e23.
@article{fb839045e07e430796ce8b0ed9f960e5,
title = "Effects of implant drill wear, irrigation, and drill materials on heat generation in osteotomy sites",
abstract = "This study evaluated the effects of drill wear on bone temperature during osteotomy preparation with 3 types of drills and compared heat production between drills. The drills used in this study were titanium nitride-coated metal, tungsten carbide carbon-coated metal, and zirconia ceramic drills. An osteotomy 11 mm in depth was formed in bovine scapular bone following the manufacturer's recommended drill sequences. Drilling was performed without irrigation and repeated 20 times; temperature was measured every 5 times. Next, 200 rounds of drilling during irrigation were performed for each drill, with temperature change monitored until round 200. Analysis of variance statistics were used for analyses of the measured data. Drilling without irrigation showed significant thermal increase at all time points compared to drilling with irrigation (P <.001). No significant difference was found between drill materials. Under irrigation, the frequency of previous drilling had minimal effects on thermal change. The repeated-measures analysis of variance revealed major thermal change at the initial time point (P <.0001), and the multiple comparison tests revealed a significant difference in temperature between the initial drills that had been used 50 or fewer times and those that had been used more than 50 times, irrespective of the drill material. The results of this study indicate that the initial drill should be changed in osteotomy preparation with irrigation after they have been used 50 times. Irrigation may be a more critical factor for the control of temperature elevation than is the drill material.",
keywords = "Frictional heat, Implant drill design, Implant drill material, Irrigation, Surface contact area",
author = "Koo, {Ki Tae} and Kim, {Min Ho} and Hae-Young Kim and Wikesj{\"o}, {Ulf M E} and Yang, {Jae Ho} and Yeo, {In Sung}",
year = "2015",
month = "4",
day = "1",
doi = "10.1563/AAID-JOI-D-13-00151",
language = "English",
volume = "41",
pages = "e19--e23",
journal = "Journal of Oral Implantology",
issn = "0160-6972",
publisher = "Allen Press Inc.",
number = "2",

}

TY - JOUR

T1 - Effects of implant drill wear, irrigation, and drill materials on heat generation in osteotomy sites

AU - Koo, Ki Tae

AU - Kim, Min Ho

AU - Kim, Hae-Young

AU - Wikesjö, Ulf M E

AU - Yang, Jae Ho

AU - Yeo, In Sung

PY - 2015/4/1

Y1 - 2015/4/1

N2 - This study evaluated the effects of drill wear on bone temperature during osteotomy preparation with 3 types of drills and compared heat production between drills. The drills used in this study were titanium nitride-coated metal, tungsten carbide carbon-coated metal, and zirconia ceramic drills. An osteotomy 11 mm in depth was formed in bovine scapular bone following the manufacturer's recommended drill sequences. Drilling was performed without irrigation and repeated 20 times; temperature was measured every 5 times. Next, 200 rounds of drilling during irrigation were performed for each drill, with temperature change monitored until round 200. Analysis of variance statistics were used for analyses of the measured data. Drilling without irrigation showed significant thermal increase at all time points compared to drilling with irrigation (P <.001). No significant difference was found between drill materials. Under irrigation, the frequency of previous drilling had minimal effects on thermal change. The repeated-measures analysis of variance revealed major thermal change at the initial time point (P <.0001), and the multiple comparison tests revealed a significant difference in temperature between the initial drills that had been used 50 or fewer times and those that had been used more than 50 times, irrespective of the drill material. The results of this study indicate that the initial drill should be changed in osteotomy preparation with irrigation after they have been used 50 times. Irrigation may be a more critical factor for the control of temperature elevation than is the drill material.

AB - This study evaluated the effects of drill wear on bone temperature during osteotomy preparation with 3 types of drills and compared heat production between drills. The drills used in this study were titanium nitride-coated metal, tungsten carbide carbon-coated metal, and zirconia ceramic drills. An osteotomy 11 mm in depth was formed in bovine scapular bone following the manufacturer's recommended drill sequences. Drilling was performed without irrigation and repeated 20 times; temperature was measured every 5 times. Next, 200 rounds of drilling during irrigation were performed for each drill, with temperature change monitored until round 200. Analysis of variance statistics were used for analyses of the measured data. Drilling without irrigation showed significant thermal increase at all time points compared to drilling with irrigation (P <.001). No significant difference was found between drill materials. Under irrigation, the frequency of previous drilling had minimal effects on thermal change. The repeated-measures analysis of variance revealed major thermal change at the initial time point (P <.0001), and the multiple comparison tests revealed a significant difference in temperature between the initial drills that had been used 50 or fewer times and those that had been used more than 50 times, irrespective of the drill material. The results of this study indicate that the initial drill should be changed in osteotomy preparation with irrigation after they have been used 50 times. Irrigation may be a more critical factor for the control of temperature elevation than is the drill material.

KW - Frictional heat

KW - Implant drill design

KW - Implant drill material

KW - Irrigation

KW - Surface contact area

UR - http://www.scopus.com/inward/record.url?scp=84927933938&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84927933938&partnerID=8YFLogxK

U2 - 10.1563/AAID-JOI-D-13-00151

DO - 10.1563/AAID-JOI-D-13-00151

M3 - Article

C2 - 24313461

AN - SCOPUS:84927933938

VL - 41

SP - e19-e23

JO - Journal of Oral Implantology

JF - Journal of Oral Implantology

SN - 0160-6972

IS - 2

ER -