Effects of NF treated water on corrosion of pipe distribution system and its implications to blending with conventionally treated water

Jongmoon Choi, Byeong Gyu Choi, Seungkwan Hong

Research output: Contribution to journalArticle

12 Citations (Scopus)

Abstract

Nanofiltration (NF) membrane has been increasingly applied for brackish water treatment and often integrated to conventional water treatment consisting of coagulation, sedimentation, and filtration (CSF) processes. In this study, the corrosion potential of NF treated water was examined in lab-scale corrosion loop tests, and the optimum design of NF process blended with CSF treated water was proposed for iron pipe corrosion prevention. Severe iron corrosion was observed when exposed to NF treated water, which was manifested by more negative values of Langelier saturation index (LSI), mainly due to high removal of hardness (Ca2+) and alkalinity (HCO3 -). Thus it was suggested that high corrosion potential by NF could be controlled by blending with CSF treated water. SEM, XRD, and XRF analyses clearly identified reduced corrosion, evidenced by less iron oxyhydroxides and more calcium carbonate on iron pipe surface, with decreasing NF treated water in blending. NF process simulation also demonstrated the improved stability of blended waters by decreasing flux and increasing recovery. Lastly, the LSI model reflecting blending ratio and NF membrane performance was newly developed for the design and operation of NF blending systems in order to lower the corrosion risk of pipe distribution systems through optimizing NF operating conditions.

Original languageEnglish
Pages (from-to)138-145
Number of pages8
JournalDesalination
Volume360
DOIs
Publication statusPublished - 2015 Mar 6

Fingerprint

Nanofiltration
distribution system
corrosion
pipe
Pipe
Corrosion
Water
coagulation
Coagulation
Sedimentation
iron
Water filtration
Iron
Nanofiltration membranes
water
sedimentation
Water treatment
water treatment
saturation
membrane

Keywords

  • Blending system
  • Iron corrosion
  • Langelier saturation index (LSI)
  • Nanofiltration (NF)
  • Pipe distribution system

ASJC Scopus subject areas

  • Chemical Engineering(all)
  • Mechanical Engineering
  • Chemistry(all)
  • Materials Science(all)
  • Water Science and Technology

Cite this

Effects of NF treated water on corrosion of pipe distribution system and its implications to blending with conventionally treated water. / Choi, Jongmoon; Choi, Byeong Gyu; Hong, Seungkwan.

In: Desalination, Vol. 360, 06.03.2015, p. 138-145.

Research output: Contribution to journalArticle

@article{25211464fec54631a6bac72a87744a3b,
title = "Effects of NF treated water on corrosion of pipe distribution system and its implications to blending with conventionally treated water",
abstract = "Nanofiltration (NF) membrane has been increasingly applied for brackish water treatment and often integrated to conventional water treatment consisting of coagulation, sedimentation, and filtration (CSF) processes. In this study, the corrosion potential of NF treated water was examined in lab-scale corrosion loop tests, and the optimum design of NF process blended with CSF treated water was proposed for iron pipe corrosion prevention. Severe iron corrosion was observed when exposed to NF treated water, which was manifested by more negative values of Langelier saturation index (LSI), mainly due to high removal of hardness (Ca2+) and alkalinity (HCO3 -). Thus it was suggested that high corrosion potential by NF could be controlled by blending with CSF treated water. SEM, XRD, and XRF analyses clearly identified reduced corrosion, evidenced by less iron oxyhydroxides and more calcium carbonate on iron pipe surface, with decreasing NF treated water in blending. NF process simulation also demonstrated the improved stability of blended waters by decreasing flux and increasing recovery. Lastly, the LSI model reflecting blending ratio and NF membrane performance was newly developed for the design and operation of NF blending systems in order to lower the corrosion risk of pipe distribution systems through optimizing NF operating conditions.",
keywords = "Blending system, Iron corrosion, Langelier saturation index (LSI), Nanofiltration (NF), Pipe distribution system",
author = "Jongmoon Choi and Choi, {Byeong Gyu} and Seungkwan Hong",
year = "2015",
month = "3",
day = "6",
doi = "10.1016/j.desal.2015.01.026",
language = "English",
volume = "360",
pages = "138--145",
journal = "Desalination",
issn = "0011-9164",
publisher = "Elsevier",

}

TY - JOUR

T1 - Effects of NF treated water on corrosion of pipe distribution system and its implications to blending with conventionally treated water

AU - Choi, Jongmoon

AU - Choi, Byeong Gyu

AU - Hong, Seungkwan

PY - 2015/3/6

Y1 - 2015/3/6

N2 - Nanofiltration (NF) membrane has been increasingly applied for brackish water treatment and often integrated to conventional water treatment consisting of coagulation, sedimentation, and filtration (CSF) processes. In this study, the corrosion potential of NF treated water was examined in lab-scale corrosion loop tests, and the optimum design of NF process blended with CSF treated water was proposed for iron pipe corrosion prevention. Severe iron corrosion was observed when exposed to NF treated water, which was manifested by more negative values of Langelier saturation index (LSI), mainly due to high removal of hardness (Ca2+) and alkalinity (HCO3 -). Thus it was suggested that high corrosion potential by NF could be controlled by blending with CSF treated water. SEM, XRD, and XRF analyses clearly identified reduced corrosion, evidenced by less iron oxyhydroxides and more calcium carbonate on iron pipe surface, with decreasing NF treated water in blending. NF process simulation also demonstrated the improved stability of blended waters by decreasing flux and increasing recovery. Lastly, the LSI model reflecting blending ratio and NF membrane performance was newly developed for the design and operation of NF blending systems in order to lower the corrosion risk of pipe distribution systems through optimizing NF operating conditions.

AB - Nanofiltration (NF) membrane has been increasingly applied for brackish water treatment and often integrated to conventional water treatment consisting of coagulation, sedimentation, and filtration (CSF) processes. In this study, the corrosion potential of NF treated water was examined in lab-scale corrosion loop tests, and the optimum design of NF process blended with CSF treated water was proposed for iron pipe corrosion prevention. Severe iron corrosion was observed when exposed to NF treated water, which was manifested by more negative values of Langelier saturation index (LSI), mainly due to high removal of hardness (Ca2+) and alkalinity (HCO3 -). Thus it was suggested that high corrosion potential by NF could be controlled by blending with CSF treated water. SEM, XRD, and XRF analyses clearly identified reduced corrosion, evidenced by less iron oxyhydroxides and more calcium carbonate on iron pipe surface, with decreasing NF treated water in blending. NF process simulation also demonstrated the improved stability of blended waters by decreasing flux and increasing recovery. Lastly, the LSI model reflecting blending ratio and NF membrane performance was newly developed for the design and operation of NF blending systems in order to lower the corrosion risk of pipe distribution systems through optimizing NF operating conditions.

KW - Blending system

KW - Iron corrosion

KW - Langelier saturation index (LSI)

KW - Nanofiltration (NF)

KW - Pipe distribution system

UR - http://www.scopus.com/inward/record.url?scp=84921452351&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84921452351&partnerID=8YFLogxK

U2 - 10.1016/j.desal.2015.01.026

DO - 10.1016/j.desal.2015.01.026

M3 - Article

AN - SCOPUS:84921452351

VL - 360

SP - 138

EP - 145

JO - Desalination

JF - Desalination

SN - 0011-9164