Electropreconcentration, gate injection, and capillary electrophoresis separation on a microchip

Research output: Contribution to journalArticle

Abstract

The nanochannel-based electropreconcentration is not compatible with successive capillary zone electrophoresis (CZE). In this study, the incompatibility is theoretically discussed and experimentally proven, and then, the development of a monolithic glass microfluidic chip for performing integrated electropreconcentration and CZE separation is described. The sample is electropreconcentrated at the interface of a micro- and nanochannel where electric double layer overlap conditions exist. Because an ion-depletion region develops at the leading front of the preconcentrated plug, a field-enhanced sample stacking effect occurs which limits the separation efficiency unless compensated for. The ion-depletion region was confirmed by monitoring the solution conductivity at discrete points in the microchannel during the preconcentration step. The solution conductivity decreased >20-fold during the preconcentration step. To overcome the effects of this region, a cross-intersection was used to shunt the ion-depleted buffer away from the analysis channel while reintroducing the running buffer. When the preconcentrated sample plug arrives at the cross-intersection, it is gate injected into the analysis channel so that fresh running buffer surrounds the plug. Under these conditions, three-peptide mixture was preconcentrated ∼200-fold in 60 s and the preconcentrated plug was successfully resolved with better than 1% relative standard deviations in migration times.

Original languageEnglish
Pages (from-to)179-186
Number of pages8
JournalJournal of Chromatography A
Volume1572
DOIs
Publication statusPublished - 2018 Oct 19

Fingerprint

Capillary electrophoresis
Capillary Electrophoresis
Buffers
Ions
Microchannels
Electrophoresis
Injections
Microfluidics
Glass
Peptides
Monitoring

Keywords

  • Capillary electrophoresis
  • Electropreconcentration
  • Gate injection
  • Ion concentration polarization

ASJC Scopus subject areas

  • Analytical Chemistry
  • Biochemistry
  • Organic Chemistry

Cite this

Electropreconcentration, gate injection, and capillary electrophoresis separation on a microchip. / Chun, Honggu.

In: Journal of Chromatography A, Vol. 1572, 19.10.2018, p. 179-186.

Research output: Contribution to journalArticle

@article{e44a307380b4489e8b3899919b8ada21,
title = "Electropreconcentration, gate injection, and capillary electrophoresis separation on a microchip",
abstract = "The nanochannel-based electropreconcentration is not compatible with successive capillary zone electrophoresis (CZE). In this study, the incompatibility is theoretically discussed and experimentally proven, and then, the development of a monolithic glass microfluidic chip for performing integrated electropreconcentration and CZE separation is described. The sample is electropreconcentrated at the interface of a micro- and nanochannel where electric double layer overlap conditions exist. Because an ion-depletion region develops at the leading front of the preconcentrated plug, a field-enhanced sample stacking effect occurs which limits the separation efficiency unless compensated for. The ion-depletion region was confirmed by monitoring the solution conductivity at discrete points in the microchannel during the preconcentration step. The solution conductivity decreased >20-fold during the preconcentration step. To overcome the effects of this region, a cross-intersection was used to shunt the ion-depleted buffer away from the analysis channel while reintroducing the running buffer. When the preconcentrated sample plug arrives at the cross-intersection, it is gate injected into the analysis channel so that fresh running buffer surrounds the plug. Under these conditions, three-peptide mixture was preconcentrated ∼200-fold in 60 s and the preconcentrated plug was successfully resolved with better than 1{\%} relative standard deviations in migration times.",
keywords = "Capillary electrophoresis, Electropreconcentration, Gate injection, Ion concentration polarization",
author = "Honggu Chun",
year = "2018",
month = "10",
day = "19",
doi = "10.1016/j.chroma.2018.08.053",
language = "English",
volume = "1572",
pages = "179--186",
journal = "Journal of Chromatography",
issn = "0021-9673",
publisher = "Elsevier",

}

TY - JOUR

T1 - Electropreconcentration, gate injection, and capillary electrophoresis separation on a microchip

AU - Chun, Honggu

PY - 2018/10/19

Y1 - 2018/10/19

N2 - The nanochannel-based electropreconcentration is not compatible with successive capillary zone electrophoresis (CZE). In this study, the incompatibility is theoretically discussed and experimentally proven, and then, the development of a monolithic glass microfluidic chip for performing integrated electropreconcentration and CZE separation is described. The sample is electropreconcentrated at the interface of a micro- and nanochannel where electric double layer overlap conditions exist. Because an ion-depletion region develops at the leading front of the preconcentrated plug, a field-enhanced sample stacking effect occurs which limits the separation efficiency unless compensated for. The ion-depletion region was confirmed by monitoring the solution conductivity at discrete points in the microchannel during the preconcentration step. The solution conductivity decreased >20-fold during the preconcentration step. To overcome the effects of this region, a cross-intersection was used to shunt the ion-depleted buffer away from the analysis channel while reintroducing the running buffer. When the preconcentrated sample plug arrives at the cross-intersection, it is gate injected into the analysis channel so that fresh running buffer surrounds the plug. Under these conditions, three-peptide mixture was preconcentrated ∼200-fold in 60 s and the preconcentrated plug was successfully resolved with better than 1% relative standard deviations in migration times.

AB - The nanochannel-based electropreconcentration is not compatible with successive capillary zone electrophoresis (CZE). In this study, the incompatibility is theoretically discussed and experimentally proven, and then, the development of a monolithic glass microfluidic chip for performing integrated electropreconcentration and CZE separation is described. The sample is electropreconcentrated at the interface of a micro- and nanochannel where electric double layer overlap conditions exist. Because an ion-depletion region develops at the leading front of the preconcentrated plug, a field-enhanced sample stacking effect occurs which limits the separation efficiency unless compensated for. The ion-depletion region was confirmed by monitoring the solution conductivity at discrete points in the microchannel during the preconcentration step. The solution conductivity decreased >20-fold during the preconcentration step. To overcome the effects of this region, a cross-intersection was used to shunt the ion-depleted buffer away from the analysis channel while reintroducing the running buffer. When the preconcentrated sample plug arrives at the cross-intersection, it is gate injected into the analysis channel so that fresh running buffer surrounds the plug. Under these conditions, three-peptide mixture was preconcentrated ∼200-fold in 60 s and the preconcentrated plug was successfully resolved with better than 1% relative standard deviations in migration times.

KW - Capillary electrophoresis

KW - Electropreconcentration

KW - Gate injection

KW - Ion concentration polarization

UR - http://www.scopus.com/inward/record.url?scp=85053074837&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85053074837&partnerID=8YFLogxK

U2 - 10.1016/j.chroma.2018.08.053

DO - 10.1016/j.chroma.2018.08.053

M3 - Article

C2 - 30170866

AN - SCOPUS:85053074837

VL - 1572

SP - 179

EP - 186

JO - Journal of Chromatography

JF - Journal of Chromatography

SN - 0021-9673

ER -