Entropy values are closely related to the degree of neuromuscular block during desflurane anesthesia: a case report

Seok Kyeong Oh, Byung Gun Lim, Young Sung Kim, Sangwoo Park, Seong Shin Kim

Research output: Contribution to journalArticle

Abstract

The Entropy™ module and bispectral index (BIS) depth-of-anesthesia monitors have been shown to be influenced by electromyographic (EMG) activity. The increase in entropy and BIS values is most likely caused by increased EMG activity and a higher level of consciousness. A strong EMG activity can increase entropy and BIS values because it is impossible to separate electroencephalography (EEG) from EMG, and this results from their overlapping power spectra. Thus, the entropy module may be more affected by EMG compared with the BIS module because it has more overlap with the power spectra of EEG and EMG. Several studies have suggested that EMG activity is most likely to increase, especially as it relates to the level of total intravenous anesthesia without a muscle relaxant or an insufficient analgesic level, which results in falsely increased entropy values. We present the case of a patient whose entropy values were falsely elevated by increased EMG activity resulting from light neuromuscular block or nociceptive stimuli during surgery even when undergoing desflurane anesthesia. This was closely related to the change in the neuromuscular block level and it was influenced by the degree of analgesia and the remifentanil infusion rate.

Original languageEnglish
Pages (from-to)3985-3991
Number of pages7
JournalJournal of International Medical Research
Volume47
Issue number8
DOIs
Publication statusPublished - 2019 Aug 1

Fingerprint

Neuromuscular Blockade
Entropy
Anesthesia
Electroencephalography
Power spectrum
Intravenous Anesthesia
Consciousness
Analgesia
Surgery
Analgesics
Muscle
desflurane
Muscles

Keywords

  • Consciousness monitors
  • electroencephalography
  • electromyography
  • inhalational anesthetics
  • neuromuscular blockade
  • spectral entropy

ASJC Scopus subject areas

  • Biochemistry
  • Cell Biology
  • Biochemistry, medical

Cite this

Entropy values are closely related to the degree of neuromuscular block during desflurane anesthesia : a case report. / Oh, Seok Kyeong; Lim, Byung Gun; Kim, Young Sung; Park, Sangwoo; Kim, Seong Shin.

In: Journal of International Medical Research, Vol. 47, No. 8, 01.08.2019, p. 3985-3991.

Research output: Contribution to journalArticle

Oh, Seok Kyeong ; Lim, Byung Gun ; Kim, Young Sung ; Park, Sangwoo ; Kim, Seong Shin. / Entropy values are closely related to the degree of neuromuscular block during desflurane anesthesia : a case report. In: Journal of International Medical Research. 2019 ; Vol. 47, No. 8. pp. 3985-3991.
@article{5471c36933654738b335f8262b3f07f6,
title = "Entropy values are closely related to the degree of neuromuscular block during desflurane anesthesia: a case report",
abstract = "The Entropy™ module and bispectral index (BIS) depth-of-anesthesia monitors have been shown to be influenced by electromyographic (EMG) activity. The increase in entropy and BIS values is most likely caused by increased EMG activity and a higher level of consciousness. A strong EMG activity can increase entropy and BIS values because it is impossible to separate electroencephalography (EEG) from EMG, and this results from their overlapping power spectra. Thus, the entropy module may be more affected by EMG compared with the BIS module because it has more overlap with the power spectra of EEG and EMG. Several studies have suggested that EMG activity is most likely to increase, especially as it relates to the level of total intravenous anesthesia without a muscle relaxant or an insufficient analgesic level, which results in falsely increased entropy values. We present the case of a patient whose entropy values were falsely elevated by increased EMG activity resulting from light neuromuscular block or nociceptive stimuli during surgery even when undergoing desflurane anesthesia. This was closely related to the change in the neuromuscular block level and it was influenced by the degree of analgesia and the remifentanil infusion rate.",
keywords = "Consciousness monitors, electroencephalography, electromyography, inhalational anesthetics, neuromuscular blockade, spectral entropy",
author = "Oh, {Seok Kyeong} and Lim, {Byung Gun} and Kim, {Young Sung} and Sangwoo Park and Kim, {Seong Shin}",
year = "2019",
month = "8",
day = "1",
doi = "10.1177/0300060519863967",
language = "English",
volume = "47",
pages = "3985--3991",
journal = "Journal of International Medical Research",
issn = "0300-0605",
publisher = "Field House Publishing LLP",
number = "8",

}

TY - JOUR

T1 - Entropy values are closely related to the degree of neuromuscular block during desflurane anesthesia

T2 - a case report

AU - Oh, Seok Kyeong

AU - Lim, Byung Gun

AU - Kim, Young Sung

AU - Park, Sangwoo

AU - Kim, Seong Shin

PY - 2019/8/1

Y1 - 2019/8/1

N2 - The Entropy™ module and bispectral index (BIS) depth-of-anesthesia monitors have been shown to be influenced by electromyographic (EMG) activity. The increase in entropy and BIS values is most likely caused by increased EMG activity and a higher level of consciousness. A strong EMG activity can increase entropy and BIS values because it is impossible to separate electroencephalography (EEG) from EMG, and this results from their overlapping power spectra. Thus, the entropy module may be more affected by EMG compared with the BIS module because it has more overlap with the power spectra of EEG and EMG. Several studies have suggested that EMG activity is most likely to increase, especially as it relates to the level of total intravenous anesthesia without a muscle relaxant or an insufficient analgesic level, which results in falsely increased entropy values. We present the case of a patient whose entropy values were falsely elevated by increased EMG activity resulting from light neuromuscular block or nociceptive stimuli during surgery even when undergoing desflurane anesthesia. This was closely related to the change in the neuromuscular block level and it was influenced by the degree of analgesia and the remifentanil infusion rate.

AB - The Entropy™ module and bispectral index (BIS) depth-of-anesthesia monitors have been shown to be influenced by electromyographic (EMG) activity. The increase in entropy and BIS values is most likely caused by increased EMG activity and a higher level of consciousness. A strong EMG activity can increase entropy and BIS values because it is impossible to separate electroencephalography (EEG) from EMG, and this results from their overlapping power spectra. Thus, the entropy module may be more affected by EMG compared with the BIS module because it has more overlap with the power spectra of EEG and EMG. Several studies have suggested that EMG activity is most likely to increase, especially as it relates to the level of total intravenous anesthesia without a muscle relaxant or an insufficient analgesic level, which results in falsely increased entropy values. We present the case of a patient whose entropy values were falsely elevated by increased EMG activity resulting from light neuromuscular block or nociceptive stimuli during surgery even when undergoing desflurane anesthesia. This was closely related to the change in the neuromuscular block level and it was influenced by the degree of analgesia and the remifentanil infusion rate.

KW - Consciousness monitors

KW - electroencephalography

KW - electromyography

KW - inhalational anesthetics

KW - neuromuscular blockade

KW - spectral entropy

UR - http://www.scopus.com/inward/record.url?scp=85071784856&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85071784856&partnerID=8YFLogxK

U2 - 10.1177/0300060519863967

DO - 10.1177/0300060519863967

M3 - Article

C2 - 31342813

AN - SCOPUS:85071784856

VL - 47

SP - 3985

EP - 3991

JO - Journal of International Medical Research

JF - Journal of International Medical Research

SN - 0300-0605

IS - 8

ER -