Enzymatically generated polyphenols as array-based metal-ion sensors

Jungbae Kim, Xiaoqiu Wu, Michelle R. Herman, Jonathan S. Dordick

Research output: Contribution to journalArticle

20 Citations (Scopus)

Abstract

Phenolic polymers containing fluorescent reporter molecules were prepared via soybean hull peroxidase (SBP) catalysis, and used as metal-based sensor components. Specifically, we generated a variety of phenolic homopolymers containing p-cresol, p-phenylphenol, or p-methoxyphenol containing one of the two fluorophores: fluorescein and calcein. The fluorescence of the resulting polyphenols was dependent on the presence of metal ions, including Cu2+, Fe2+, Zn2+, Mn2+, and Fe3+. The fluorescence response was dependent on both, the metal ion and the phenolic monomer used in polyphenol synthesis, indicating that significant control over the selectivity and sensitivity of metal sensing can be achieved by varying the components that comprise the phenolic polymer. In some cases, metal-ion concentrations as low as 10μM can be analyzed. The broad reactivity of SBP toward phenolic monomers enables the use of a wide array of structures and chemistries that can assist in metal-ion detection. Copyright (C) 1998 Elsevier Science B.V.

Original languageEnglish
Pages (from-to)251-258
Number of pages8
JournalAnalytica Chimica Acta
Volume370
Issue number2-3
DOIs
Publication statusPublished - 1998 Sep 7
Externally publishedYes

Fingerprint

Polyphenols
Metal ions
Metals
Ions
sensor
ion
metal
Sensors
Peroxidase
Polymers
Monomers
Fluorescence
hull
Soybeans
soybean
Fluorophores
fluorescence
polymer
Homopolymerization
Fluorescein

Keywords

  • Array-based sensors
  • Fluorophores
  • Metal-ion detection
  • Peroxidase
  • Phenolic polymers

ASJC Scopus subject areas

  • Biochemistry
  • Analytical Chemistry
  • Spectroscopy
  • Environmental Chemistry

Cite this

Enzymatically generated polyphenols as array-based metal-ion sensors. / Kim, Jungbae; Wu, Xiaoqiu; Herman, Michelle R.; Dordick, Jonathan S.

In: Analytica Chimica Acta, Vol. 370, No. 2-3, 07.09.1998, p. 251-258.

Research output: Contribution to journalArticle

Kim, Jungbae ; Wu, Xiaoqiu ; Herman, Michelle R. ; Dordick, Jonathan S. / Enzymatically generated polyphenols as array-based metal-ion sensors. In: Analytica Chimica Acta. 1998 ; Vol. 370, No. 2-3. pp. 251-258.
@article{90465eecf3c54c42adf2dc8521ddee75,
title = "Enzymatically generated polyphenols as array-based metal-ion sensors",
abstract = "Phenolic polymers containing fluorescent reporter molecules were prepared via soybean hull peroxidase (SBP) catalysis, and used as metal-based sensor components. Specifically, we generated a variety of phenolic homopolymers containing p-cresol, p-phenylphenol, or p-methoxyphenol containing one of the two fluorophores: fluorescein and calcein. The fluorescence of the resulting polyphenols was dependent on the presence of metal ions, including Cu2+, Fe2+, Zn2+, Mn2+, and Fe3+. The fluorescence response was dependent on both, the metal ion and the phenolic monomer used in polyphenol synthesis, indicating that significant control over the selectivity and sensitivity of metal sensing can be achieved by varying the components that comprise the phenolic polymer. In some cases, metal-ion concentrations as low as 10μM can be analyzed. The broad reactivity of SBP toward phenolic monomers enables the use of a wide array of structures and chemistries that can assist in metal-ion detection. Copyright (C) 1998 Elsevier Science B.V.",
keywords = "Array-based sensors, Fluorophores, Metal-ion detection, Peroxidase, Phenolic polymers",
author = "Jungbae Kim and Xiaoqiu Wu and Herman, {Michelle R.} and Dordick, {Jonathan S.}",
year = "1998",
month = "9",
day = "7",
doi = "10.1016/S0003-2670(98)00292-X",
language = "English",
volume = "370",
pages = "251--258",
journal = "Analytica Chimica Acta",
issn = "0003-2670",
publisher = "Elsevier",
number = "2-3",

}

TY - JOUR

T1 - Enzymatically generated polyphenols as array-based metal-ion sensors

AU - Kim, Jungbae

AU - Wu, Xiaoqiu

AU - Herman, Michelle R.

AU - Dordick, Jonathan S.

PY - 1998/9/7

Y1 - 1998/9/7

N2 - Phenolic polymers containing fluorescent reporter molecules were prepared via soybean hull peroxidase (SBP) catalysis, and used as metal-based sensor components. Specifically, we generated a variety of phenolic homopolymers containing p-cresol, p-phenylphenol, or p-methoxyphenol containing one of the two fluorophores: fluorescein and calcein. The fluorescence of the resulting polyphenols was dependent on the presence of metal ions, including Cu2+, Fe2+, Zn2+, Mn2+, and Fe3+. The fluorescence response was dependent on both, the metal ion and the phenolic monomer used in polyphenol synthesis, indicating that significant control over the selectivity and sensitivity of metal sensing can be achieved by varying the components that comprise the phenolic polymer. In some cases, metal-ion concentrations as low as 10μM can be analyzed. The broad reactivity of SBP toward phenolic monomers enables the use of a wide array of structures and chemistries that can assist in metal-ion detection. Copyright (C) 1998 Elsevier Science B.V.

AB - Phenolic polymers containing fluorescent reporter molecules were prepared via soybean hull peroxidase (SBP) catalysis, and used as metal-based sensor components. Specifically, we generated a variety of phenolic homopolymers containing p-cresol, p-phenylphenol, or p-methoxyphenol containing one of the two fluorophores: fluorescein and calcein. The fluorescence of the resulting polyphenols was dependent on the presence of metal ions, including Cu2+, Fe2+, Zn2+, Mn2+, and Fe3+. The fluorescence response was dependent on both, the metal ion and the phenolic monomer used in polyphenol synthesis, indicating that significant control over the selectivity and sensitivity of metal sensing can be achieved by varying the components that comprise the phenolic polymer. In some cases, metal-ion concentrations as low as 10μM can be analyzed. The broad reactivity of SBP toward phenolic monomers enables the use of a wide array of structures and chemistries that can assist in metal-ion detection. Copyright (C) 1998 Elsevier Science B.V.

KW - Array-based sensors

KW - Fluorophores

KW - Metal-ion detection

KW - Peroxidase

KW - Phenolic polymers

UR - http://www.scopus.com/inward/record.url?scp=0031877375&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031877375&partnerID=8YFLogxK

U2 - 10.1016/S0003-2670(98)00292-X

DO - 10.1016/S0003-2670(98)00292-X

M3 - Article

AN - SCOPUS:0031877375

VL - 370

SP - 251

EP - 258

JO - Analytica Chimica Acta

JF - Analytica Chimica Acta

SN - 0003-2670

IS - 2-3

ER -