Evaluation of membrane-based desalting processes for RO brine treatment

Songbok Lee, Youngjin Kim, Albert S. Kim, Seungkwan Hong

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

Membrane-based desalting processes including reverse osmosis (RO), forward osmosis (FO), and membrane distillation (MD) were systematically evaluated for concentrating RO brine. Basic characteristics of membrane processes were first examined. Commercial polyamide RO exhibited higher water and lower salt permeability coefficients than cellulose FO membrane. However, salt rejection by FO seemed to be higher than RO primarily due to the hindrance of reverse draw solute flux. The water flux of MD comparable to RO was obtained when temperature gradient was more than 20–30°C. The applicability of RO, FO, and MD was further tested with real brine obtained from full-scale RO plant processing brackish water. Results demonstrated that water flux was not significantly reduced in MD, while severe flux decline was observed in both RO and FO at high recovery. To elucidate major causes of different flux behaviors, the fouled membrane surfaces were analyzed by scanning electron microscopy with energy dispersive X-ray spectroscopy and X-ray diffraction. Foulant analysis suggested that CaCO3 scaling occurred particularly at high water recovery, which was in good agreement with water quality simulation. CaCO3 scaling, however, had only small impact on flux behavior in MD. From these findings, MD could be suggested as the best option for concentrating industrial RO brine if low-grade heat (below 50–70°C) is available.

Original languageEnglish
JournalDesalination and Water Treatment
DOIs
Publication statusAccepted/In press - 2015 Apr 5

Fingerprint

Salt removal
Reverse osmosis
brine
membrane
Membranes
Distillation
distillation
Osmosis
osmosis
Fluxes
Water
Salts
reverse osmosis
evaluation
Recovery
Osmosis membranes
salt
water
Hydraulic conductivity
Polyamides

Keywords

  • Forward osmosis
  • Membrane distillation
  • Membrane fouling
  • Reverse osmosis
  • RO brine

ASJC Scopus subject areas

  • Pollution
  • Water Science and Technology
  • Ocean Engineering

Cite this

Evaluation of membrane-based desalting processes for RO brine treatment. / Lee, Songbok; Kim, Youngjin; Kim, Albert S.; Hong, Seungkwan.

In: Desalination and Water Treatment, 05.04.2015.

Research output: Contribution to journalArticle

@article{64fd798008c745cab50eafabb38b9ca5,
title = "Evaluation of membrane-based desalting processes for RO brine treatment",
abstract = "Membrane-based desalting processes including reverse osmosis (RO), forward osmosis (FO), and membrane distillation (MD) were systematically evaluated for concentrating RO brine. Basic characteristics of membrane processes were first examined. Commercial polyamide RO exhibited higher water and lower salt permeability coefficients than cellulose FO membrane. However, salt rejection by FO seemed to be higher than RO primarily due to the hindrance of reverse draw solute flux. The water flux of MD comparable to RO was obtained when temperature gradient was more than 20–30°C. The applicability of RO, FO, and MD was further tested with real brine obtained from full-scale RO plant processing brackish water. Results demonstrated that water flux was not significantly reduced in MD, while severe flux decline was observed in both RO and FO at high recovery. To elucidate major causes of different flux behaviors, the fouled membrane surfaces were analyzed by scanning electron microscopy with energy dispersive X-ray spectroscopy and X-ray diffraction. Foulant analysis suggested that CaCO3 scaling occurred particularly at high water recovery, which was in good agreement with water quality simulation. CaCO3 scaling, however, had only small impact on flux behavior in MD. From these findings, MD could be suggested as the best option for concentrating industrial RO brine if low-grade heat (below 50–70°C) is available.",
keywords = "Forward osmosis, Membrane distillation, Membrane fouling, Reverse osmosis, RO brine",
author = "Songbok Lee and Youngjin Kim and Kim, {Albert S.} and Seungkwan Hong",
year = "2015",
month = "4",
day = "5",
doi = "10.1080/19443994.2015.1030120",
language = "English",
journal = "Desalination and Water Treatment",
issn = "1944-3994",
publisher = "Taylor and Francis Ltd.",

}

TY - JOUR

T1 - Evaluation of membrane-based desalting processes for RO brine treatment

AU - Lee, Songbok

AU - Kim, Youngjin

AU - Kim, Albert S.

AU - Hong, Seungkwan

PY - 2015/4/5

Y1 - 2015/4/5

N2 - Membrane-based desalting processes including reverse osmosis (RO), forward osmosis (FO), and membrane distillation (MD) were systematically evaluated for concentrating RO brine. Basic characteristics of membrane processes were first examined. Commercial polyamide RO exhibited higher water and lower salt permeability coefficients than cellulose FO membrane. However, salt rejection by FO seemed to be higher than RO primarily due to the hindrance of reverse draw solute flux. The water flux of MD comparable to RO was obtained when temperature gradient was more than 20–30°C. The applicability of RO, FO, and MD was further tested with real brine obtained from full-scale RO plant processing brackish water. Results demonstrated that water flux was not significantly reduced in MD, while severe flux decline was observed in both RO and FO at high recovery. To elucidate major causes of different flux behaviors, the fouled membrane surfaces were analyzed by scanning electron microscopy with energy dispersive X-ray spectroscopy and X-ray diffraction. Foulant analysis suggested that CaCO3 scaling occurred particularly at high water recovery, which was in good agreement with water quality simulation. CaCO3 scaling, however, had only small impact on flux behavior in MD. From these findings, MD could be suggested as the best option for concentrating industrial RO brine if low-grade heat (below 50–70°C) is available.

AB - Membrane-based desalting processes including reverse osmosis (RO), forward osmosis (FO), and membrane distillation (MD) were systematically evaluated for concentrating RO brine. Basic characteristics of membrane processes were first examined. Commercial polyamide RO exhibited higher water and lower salt permeability coefficients than cellulose FO membrane. However, salt rejection by FO seemed to be higher than RO primarily due to the hindrance of reverse draw solute flux. The water flux of MD comparable to RO was obtained when temperature gradient was more than 20–30°C. The applicability of RO, FO, and MD was further tested with real brine obtained from full-scale RO plant processing brackish water. Results demonstrated that water flux was not significantly reduced in MD, while severe flux decline was observed in both RO and FO at high recovery. To elucidate major causes of different flux behaviors, the fouled membrane surfaces were analyzed by scanning electron microscopy with energy dispersive X-ray spectroscopy and X-ray diffraction. Foulant analysis suggested that CaCO3 scaling occurred particularly at high water recovery, which was in good agreement with water quality simulation. CaCO3 scaling, however, had only small impact on flux behavior in MD. From these findings, MD could be suggested as the best option for concentrating industrial RO brine if low-grade heat (below 50–70°C) is available.

KW - Forward osmosis

KW - Membrane distillation

KW - Membrane fouling

KW - Reverse osmosis

KW - RO brine

UR - http://www.scopus.com/inward/record.url?scp=84927556239&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84927556239&partnerID=8YFLogxK

U2 - 10.1080/19443994.2015.1030120

DO - 10.1080/19443994.2015.1030120

M3 - Article

JO - Desalination and Water Treatment

JF - Desalination and Water Treatment

SN - 1944-3994

ER -