Abstract

Energy and exergy performance of adsorption storage system was studied experimentally for residential application. A fin-coated heat exchanger was adopted for a sorption bed to quicken the charging process. When the regeneration temperature was 70°C, ambient temperature was 30°C, HTF (heat transfer fluid) inlet temperature for the adsorption bed was 30°C, results showed that the heat ESD (energy storage density) was approximately 805kJ/kg with the energy efficiency approximately 96%. The exergy efficiency was 26.7% and the loading difference was 0.164. In this study the mass flow rate of the adsorption bed affected more on the storage performance than that of the desorption bed. As the mass flow rate was increased, the ESD increased while the exergy efficiency decreased due to the larger exergy destruction caused by pressure drop. Increasing regeneration temperature and decreasing adsorption temperature could make the ESD and energy efficiency increased, but the exergy efficiency decreased. As ambient temperature was increased, total ESD and energy efficiency increased, and overall exergy efficiency decreased. A larger loading difference could be achieved with increasing the adsorption bed HTF mass flow rate, regeneration temperature, and inlet temperature of HTF for the evaporator, or decreasing inlet temperature of HTF for the adsorption bed.

Original languageEnglish
Pages (from-to)675-691
Number of pages17
JournalEnergy
Volume65
DOIs
Publication statusPublished - 2014 Feb 1
Externally publishedYes

Fingerprint

Heat storage
Exergy
Adsorption
Energy storage
Temperature
Heat transfer
Energy efficiency
Fluids
Flow rate
Evaporators
Pressure drop
Heat exchangers
Sorption
Desorption

Keywords

  • Adsorption heat storage
  • Energy storage density
  • Exergy destruction
  • Exergy performance
  • Fin-coated heat exchanger
  • Thermal energy storage

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Building and Construction
  • Pollution
  • Mechanical Engineering
  • Industrial and Manufacturing Engineering
  • Electrical and Electronic Engineering

Cite this

Experimental investigation of energy and exergy performance of short term adsorption heat storage for residential application. / Li, Gang; Qian, Suxin; Lee, Hoseong; Hwang, Yunho; Radermacher, Reinhard.

In: Energy, Vol. 65, 01.02.2014, p. 675-691.

Research output: Contribution to journalArticle

Li, Gang ; Qian, Suxin ; Lee, Hoseong ; Hwang, Yunho ; Radermacher, Reinhard. / Experimental investigation of energy and exergy performance of short term adsorption heat storage for residential application. In: Energy. 2014 ; Vol. 65. pp. 675-691.
@article{ab8ce6f1ed6549d386160d1781fb2cce,
title = "Experimental investigation of energy and exergy performance of short term adsorption heat storage for residential application",
abstract = "Energy and exergy performance of adsorption storage system was studied experimentally for residential application. A fin-coated heat exchanger was adopted for a sorption bed to quicken the charging process. When the regeneration temperature was 70°C, ambient temperature was 30°C, HTF (heat transfer fluid) inlet temperature for the adsorption bed was 30°C, results showed that the heat ESD (energy storage density) was approximately 805kJ/kg with the energy efficiency approximately 96{\%}. The exergy efficiency was 26.7{\%} and the loading difference was 0.164. In this study the mass flow rate of the adsorption bed affected more on the storage performance than that of the desorption bed. As the mass flow rate was increased, the ESD increased while the exergy efficiency decreased due to the larger exergy destruction caused by pressure drop. Increasing regeneration temperature and decreasing adsorption temperature could make the ESD and energy efficiency increased, but the exergy efficiency decreased. As ambient temperature was increased, total ESD and energy efficiency increased, and overall exergy efficiency decreased. A larger loading difference could be achieved with increasing the adsorption bed HTF mass flow rate, regeneration temperature, and inlet temperature of HTF for the evaporator, or decreasing inlet temperature of HTF for the adsorption bed.",
keywords = "Adsorption heat storage, Energy storage density, Exergy destruction, Exergy performance, Fin-coated heat exchanger, Thermal energy storage",
author = "Gang Li and Suxin Qian and Hoseong Lee and Yunho Hwang and Reinhard Radermacher",
year = "2014",
month = "2",
day = "1",
doi = "10.1016/j.energy.2013.12.017",
language = "English",
volume = "65",
pages = "675--691",
journal = "Energy",
issn = "0360-5442",
publisher = "Elsevier Limited",

}

TY - JOUR

T1 - Experimental investigation of energy and exergy performance of short term adsorption heat storage for residential application

AU - Li, Gang

AU - Qian, Suxin

AU - Lee, Hoseong

AU - Hwang, Yunho

AU - Radermacher, Reinhard

PY - 2014/2/1

Y1 - 2014/2/1

N2 - Energy and exergy performance of adsorption storage system was studied experimentally for residential application. A fin-coated heat exchanger was adopted for a sorption bed to quicken the charging process. When the regeneration temperature was 70°C, ambient temperature was 30°C, HTF (heat transfer fluid) inlet temperature for the adsorption bed was 30°C, results showed that the heat ESD (energy storage density) was approximately 805kJ/kg with the energy efficiency approximately 96%. The exergy efficiency was 26.7% and the loading difference was 0.164. In this study the mass flow rate of the adsorption bed affected more on the storage performance than that of the desorption bed. As the mass flow rate was increased, the ESD increased while the exergy efficiency decreased due to the larger exergy destruction caused by pressure drop. Increasing regeneration temperature and decreasing adsorption temperature could make the ESD and energy efficiency increased, but the exergy efficiency decreased. As ambient temperature was increased, total ESD and energy efficiency increased, and overall exergy efficiency decreased. A larger loading difference could be achieved with increasing the adsorption bed HTF mass flow rate, regeneration temperature, and inlet temperature of HTF for the evaporator, or decreasing inlet temperature of HTF for the adsorption bed.

AB - Energy and exergy performance of adsorption storage system was studied experimentally for residential application. A fin-coated heat exchanger was adopted for a sorption bed to quicken the charging process. When the regeneration temperature was 70°C, ambient temperature was 30°C, HTF (heat transfer fluid) inlet temperature for the adsorption bed was 30°C, results showed that the heat ESD (energy storage density) was approximately 805kJ/kg with the energy efficiency approximately 96%. The exergy efficiency was 26.7% and the loading difference was 0.164. In this study the mass flow rate of the adsorption bed affected more on the storage performance than that of the desorption bed. As the mass flow rate was increased, the ESD increased while the exergy efficiency decreased due to the larger exergy destruction caused by pressure drop. Increasing regeneration temperature and decreasing adsorption temperature could make the ESD and energy efficiency increased, but the exergy efficiency decreased. As ambient temperature was increased, total ESD and energy efficiency increased, and overall exergy efficiency decreased. A larger loading difference could be achieved with increasing the adsorption bed HTF mass flow rate, regeneration temperature, and inlet temperature of HTF for the evaporator, or decreasing inlet temperature of HTF for the adsorption bed.

KW - Adsorption heat storage

KW - Energy storage density

KW - Exergy destruction

KW - Exergy performance

KW - Fin-coated heat exchanger

KW - Thermal energy storage

UR - http://www.scopus.com/inward/record.url?scp=84892967828&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84892967828&partnerID=8YFLogxK

U2 - 10.1016/j.energy.2013.12.017

DO - 10.1016/j.energy.2013.12.017

M3 - Article

AN - SCOPUS:84892967828

VL - 65

SP - 675

EP - 691

JO - Energy

JF - Energy

SN - 0360-5442

ER -