Experimental study of inter-laminar core fault detection techniques based on low flux core excitation

Sang Bin Lee, Gerald Kliman, Manoj Shah, Dongwook Kim, Tony Mall, Kutty Nair, Mark Lusted

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

A comparison between two inter-laminar stator core insulation failure detection techniques for generators based on low flux core excitation is presented in this paper. The two techniques under consideration are: 1) the iron core probe based method developed recently and 2) the existing air core probe based method. A qualitative comparison of the two techniques is presented along with an experimental comparison on a 120MW generator stator core. The test results are compared in terms of fault detection sensitivity, signal to noise ratio, and ease of interpretation, which are the main requirements for stator core inspection. In addition to the comparison, the performance of the iron core probe technique for machines with short wedge depression depth is presented along with the recent improvements in the algorithm. It is shown that the main requirements for stator core inspection are significantly enhanced with the new iron core probe-based core fault detector.

Original languageEnglish
Title of host publicationSDEMPED 2005 - International Symposium on Diagnostics of Electric Machines, Power Electronics, and Drives
DOIs
Publication statusPublished - 2005 Dec 1
Externally publishedYes
EventInternational Symposium on Diagnostics of Electric Machines, Power Electronics, and Drives, SDEMPED 2005 - Vienna, Austria
Duration: 2005 Sep 72005 Sep 9

Other

OtherInternational Symposium on Diagnostics of Electric Machines, Power Electronics, and Drives, SDEMPED 2005
CountryAustria
CityVienna
Period05/9/705/9/9

Fingerprint

Fault detection
Stators
Fluxes
Iron
Inspection
Insulation
Signal to noise ratio
Detectors
Air

ASJC Scopus subject areas

  • Energy Engineering and Power Technology
  • Electrical and Electronic Engineering

Cite this

Lee, S. B., Kliman, G., Shah, M., Kim, D., Mall, T., Nair, K., & Lusted, M. (2005). Experimental study of inter-laminar core fault detection techniques based on low flux core excitation. In SDEMPED 2005 - International Symposium on Diagnostics of Electric Machines, Power Electronics, and Drives [4662550] https://doi.org/10.1109/DEMPED.2005.4662550

Experimental study of inter-laminar core fault detection techniques based on low flux core excitation. / Lee, Sang Bin; Kliman, Gerald; Shah, Manoj; Kim, Dongwook; Mall, Tony; Nair, Kutty; Lusted, Mark.

SDEMPED 2005 - International Symposium on Diagnostics of Electric Machines, Power Electronics, and Drives. 2005. 4662550.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Lee, SB, Kliman, G, Shah, M, Kim, D, Mall, T, Nair, K & Lusted, M 2005, Experimental study of inter-laminar core fault detection techniques based on low flux core excitation. in SDEMPED 2005 - International Symposium on Diagnostics of Electric Machines, Power Electronics, and Drives., 4662550, International Symposium on Diagnostics of Electric Machines, Power Electronics, and Drives, SDEMPED 2005, Vienna, Austria, 05/9/7. https://doi.org/10.1109/DEMPED.2005.4662550
Lee SB, Kliman G, Shah M, Kim D, Mall T, Nair K et al. Experimental study of inter-laminar core fault detection techniques based on low flux core excitation. In SDEMPED 2005 - International Symposium on Diagnostics of Electric Machines, Power Electronics, and Drives. 2005. 4662550 https://doi.org/10.1109/DEMPED.2005.4662550
Lee, Sang Bin ; Kliman, Gerald ; Shah, Manoj ; Kim, Dongwook ; Mall, Tony ; Nair, Kutty ; Lusted, Mark. / Experimental study of inter-laminar core fault detection techniques based on low flux core excitation. SDEMPED 2005 - International Symposium on Diagnostics of Electric Machines, Power Electronics, and Drives. 2005.
@inproceedings{dac76360807c46af9e331fb42aba6c60,
title = "Experimental study of inter-laminar core fault detection techniques based on low flux core excitation",
abstract = "A comparison between two inter-laminar stator core insulation failure detection techniques for generators based on low flux core excitation is presented in this paper. The two techniques under consideration are: 1) the iron core probe based method developed recently and 2) the existing air core probe based method. A qualitative comparison of the two techniques is presented along with an experimental comparison on a 120MW generator stator core. The test results are compared in terms of fault detection sensitivity, signal to noise ratio, and ease of interpretation, which are the main requirements for stator core inspection. In addition to the comparison, the performance of the iron core probe technique for machines with short wedge depression depth is presented along with the recent improvements in the algorithm. It is shown that the main requirements for stator core inspection are significantly enhanced with the new iron core probe-based core fault detector.",
author = "Lee, {Sang Bin} and Gerald Kliman and Manoj Shah and Dongwook Kim and Tony Mall and Kutty Nair and Mark Lusted",
year = "2005",
month = "12",
day = "1",
doi = "10.1109/DEMPED.2005.4662550",
language = "English",
isbn = "0780391241",
booktitle = "SDEMPED 2005 - International Symposium on Diagnostics of Electric Machines, Power Electronics, and Drives",

}

TY - GEN

T1 - Experimental study of inter-laminar core fault detection techniques based on low flux core excitation

AU - Lee, Sang Bin

AU - Kliman, Gerald

AU - Shah, Manoj

AU - Kim, Dongwook

AU - Mall, Tony

AU - Nair, Kutty

AU - Lusted, Mark

PY - 2005/12/1

Y1 - 2005/12/1

N2 - A comparison between two inter-laminar stator core insulation failure detection techniques for generators based on low flux core excitation is presented in this paper. The two techniques under consideration are: 1) the iron core probe based method developed recently and 2) the existing air core probe based method. A qualitative comparison of the two techniques is presented along with an experimental comparison on a 120MW generator stator core. The test results are compared in terms of fault detection sensitivity, signal to noise ratio, and ease of interpretation, which are the main requirements for stator core inspection. In addition to the comparison, the performance of the iron core probe technique for machines with short wedge depression depth is presented along with the recent improvements in the algorithm. It is shown that the main requirements for stator core inspection are significantly enhanced with the new iron core probe-based core fault detector.

AB - A comparison between two inter-laminar stator core insulation failure detection techniques for generators based on low flux core excitation is presented in this paper. The two techniques under consideration are: 1) the iron core probe based method developed recently and 2) the existing air core probe based method. A qualitative comparison of the two techniques is presented along with an experimental comparison on a 120MW generator stator core. The test results are compared in terms of fault detection sensitivity, signal to noise ratio, and ease of interpretation, which are the main requirements for stator core inspection. In addition to the comparison, the performance of the iron core probe technique for machines with short wedge depression depth is presented along with the recent improvements in the algorithm. It is shown that the main requirements for stator core inspection are significantly enhanced with the new iron core probe-based core fault detector.

UR - http://www.scopus.com/inward/record.url?scp=57849139425&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=57849139425&partnerID=8YFLogxK

U2 - 10.1109/DEMPED.2005.4662550

DO - 10.1109/DEMPED.2005.4662550

M3 - Conference contribution

AN - SCOPUS:57849139425

SN - 0780391241

SN - 9780780391246

BT - SDEMPED 2005 - International Symposium on Diagnostics of Electric Machines, Power Electronics, and Drives

ER -